Literature DB >> 23578738

CLSI-based transference of the CALIPER database of pediatric reference intervals from Abbott to Beckman, Ortho, Roche and Siemens Clinical Chemistry Assays: direct validation using reference samples from the CALIPER cohort.

Mathew P Estey1, Ashley H Cohen, David A Colantonio, Man Khun Chan, Tina Binesh Marvasti, Edward Randell, Edgard Delvin, Jocelyne Cousineau, Vijaylaxmi Grey, Donald Greenway, Qing H Meng, Benjamin Jung, Jalaluddin Bhuiyan, David Seccombe, Khosrow Adeli.   

Abstract

OBJECTIVES: The CALIPER program recently established a comprehensive database of age- and sex-stratified pediatric reference intervals for 40 biochemical markers. However, this database was only directly applicable for Abbott ARCHITECT assays. We therefore sought to expand the scope of this database to biochemical assays from other major manufacturers, allowing for a much wider application of the CALIPER database. DESIGN AND METHODS: Based on CLSI C28-A3 and EP9-A2 guidelines, CALIPER reference intervals were transferred (using specific statistical criteria) to assays performed on four other commonly used clinical chemistry platforms including Beckman Coulter DxC800, Ortho Vitros 5600, Roche Cobas 6000, and Siemens Vista 1500. The resulting reference intervals were subjected to a thorough validation using 100 reference specimens (healthy community children and adolescents) from the CALIPER bio-bank, and all testing centers participated in an external quality assessment (EQA) evaluation.
RESULTS: In general, the transferred pediatric reference intervals were similar to those established in our previous study. However, assay-specific differences in reference limits were observed for many analytes, and in some instances were considerable. The results of the EQA evaluation generally mimicked the similarities and differences in reference limits among the five manufacturers' assays. In addition, the majority of transferred reference intervals were validated through the analysis of CALIPER reference samples.
CONCLUSIONS: This study greatly extends the utility of the CALIPER reference interval database which is now directly applicable for assays performed on five major analytical platforms in clinical use, and should permit the worldwide application of CALIPER pediatric reference intervals.
Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Abbott; Beckman; Biochemical markers; CALIPER; CEQAL; CLSI; Canadian External Quality Assessment Laboratory; Canadian Laboratory Initiative in Pediatric Reference Intervals; Clinical Laboratory Standards Institute; EQA; External quality assessment; Ortho; Pediatric; Q–Q; Reference intervals; Roche; Siemens; Transference; quantile–quantile

Mesh:

Substances:

Year:  2013        PMID: 23578738     DOI: 10.1016/j.clinbiochem.2013.04.001

Source DB:  PubMed          Journal:  Clin Biochem        ISSN: 0009-9120            Impact factor:   3.281


  24 in total

1.  Assessment of Heart and Liver Iron Overload in Thalassemia Major Patients Using T2* Magnetic Resonance Imaging.

Authors:  Hamid Farhangi; Zahra Badiei; Hasan Mottaghi Moghaddam; Mohammad Reza Keramati
Journal:  Indian J Hematol Blood Transfus       Date:  2016-06-15       Impact factor: 0.900

Review 2.  Bone Turnover Markers in Children: From Laboratory Challenges to Clinical Interpretation.

Authors:  Aurélie Ladang; Frank Rauch; Edgard Delvin; Etienne Cavalier
Journal:  Calcif Tissue Int       Date:  2022-03-04       Impact factor: 4.333

Review 3.  Hypophosphatasia: Biological and Clinical Aspects, Avenues for Therapy.

Authors:  Jean Pierre Salles
Journal:  Clin Biochem Rev       Date:  2020-02

4.  Biomarkers for liver disease in urea cycle disorders.

Authors:  Sandesh C S Nagamani; Saima Ali; Rima Izem; Deborah Schady; Prakash Masand; Benjamin L Shneider; Daniel H Leung; Lindsay C Burrage
Journal:  Mol Genet Metab       Date:  2021-04-08       Impact factor: 4.204

5.  Clinical use of shear-wave elastography for detecting liver fibrosis in children and adolescents with cystic fibrosis.

Authors:  Steven Levitte; Lori W Lee; Jared Isaacson; Evan J Zucker; Carlos Milla; Richard A Barth; Zachary M Sellers
Journal:  Pediatr Radiol       Date:  2021-03-24

6.  Prevalence of Low Serum Alkaline Phosphatase and Hypophosphatasia in Adult Patients with Atypical Femur Fractures.

Authors:  Eleni Tsiantouli; Emmanuel Biver; Thierry Chevalley; Robert Petrovic; Didier Hannouche; Serge Ferrari
Journal:  Calcif Tissue Int       Date:  2022-02-28       Impact factor: 4.000

Review 7.  Advances in Pediatric Reference Intervals for Biochemical Markers: Establishment of the Caliper Database in Healthy Children and Adolescents.

Authors:  Kimiya Karbasy; Petra Ariadne; Stephanie Gaglione; Michelle Nieuwesteeg; Khosrow Adeli
Journal:  J Med Biochem       Date:  2014-10-08       Impact factor: 3.402

Review 8.  Pediatric Non-Alcoholic Fatty Liver Disease.

Authors:  Edgard Delvin; Natasha Patey; Josée Dubois; Melanie Henderson; Émile Lévy
Journal:  J Med Biochem       Date:  2014-10-08       Impact factor: 3.402

Review 9.  Reference intervals: current status, recent developments and future considerations.

Authors:  Yesim Ozarda
Journal:  Biochem Med (Zagreb)       Date:  2016       Impact factor: 2.313

10.  Opinion Paper: Deriving Harmonised Reference Intervals - Global Activities.

Authors:  Jillian R Tate; Gus Koerbin; Khosrow Adeli
Journal:  EJIFCC       Date:  2016-02-09
View more