Literature DB >> 23569665

Proximal humeral fractures: a biomechanical comparison of locking plate constructs in a cadaveric 3-part fracture model.

David M Rose1, Edward G Sutter, Simon C Mears, Rohit R Gupta, Stephen M Belkoff.   

Abstract

The purpose of our study was to biomechanically compare, under cyclic loading conditions, fracture site motion, humeral head collapse, and intra-articular hardware penetration in simulated 3-part osteoporotic proximal humeral fractures stabilized with 1 of 2 locking-plate constructs. We performed fixation on simulated 3-part proximal humeral fractures in 10 pairs of cadaveric osteoporotic humeri with a Hand Innovations S3 Proximal Humerus Plate (S3 plate) or an LCP Proximal Humerus Plate (LCP plate; 1 each for each pair). The specimens were potted, mounted on a materials testing machine, and subjected to 5000 cycles of abduction in the scapular plane, loading through the supraspinatus tendon. Interfragmentary displacement at 2 virtual points (the most medial aspect of the calcar and the most superior aspect of the osteotomy line between the greater tuberosity and humeral head) was measured using an optical tracking system. Humeral head rotation was also measured. We used a generalized linear latent and mixed model to check for an effect of cyclic loading and treatment on the parameters of interest (significance, P < .05). After cyclic loading, the S3 plate humeri showed significantly greater displacement of the greater tuberosity fragment and rotation of the humeral head and a trend (not a significant difference) toward greater displacement at the calcar. No hardware penetration was noted for either repair. Although the S3 plate repairs resulted in significantly more fracture site motion, it is unknown whether the magnitude of the motion is clinically significant.

Entities:  

Keywords:  biomechanics; locking plates; osteoporosis; proximal humerus fracture

Year:  2010        PMID: 23569665      PMCID: PMC3597298          DOI: 10.1177/2151458510388179

Source DB:  PubMed          Journal:  Geriatr Orthop Surg Rehabil        ISSN: 2151-4585


  19 in total

1.  Device-specific thresholds to diagnose osteoporosis at the proximal femur: an approach to interpreting peripheral bone measurements in clinical practice.

Authors:  J A Clowes; N F A Peel; R Eastell
Journal:  Osteoporos Int       Date:  2006-06-30       Impact factor: 4.507

2.  Locked plate fixation and intramedullary nailing for proximal humerus fractures: a biomechanical evaluation.

Authors:  Martin Henri Hessmann; Werner Sternstein Matthias Hansen; Frank Krummenauer; Tamara Fischer Pol; Pol Maria Rommens
Journal:  J Trauma       Date:  2005-06

3.  Outcome after hemiarthroplasty for three- and four-part fractures of the proximal humerus.

Authors:  K Zyto; W A Wallace; S P Frostick; B J Preston
Journal:  J Shoulder Elbow Surg       Date:  1998 Mar-Apr       Impact factor: 3.019

4.  Forces at the glenohumeral joint in abduction.

Authors:  N K Poppen; P S Walker
Journal:  Clin Orthop Relat Res       Date:  1978-09       Impact factor: 4.176

5.  Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri.

Authors:  Paul C Siffri; Richard D Peindl; Edward R Coley; James Norton; Patrick M Connor; James F Kellam
Journal:  J Orthop Trauma       Date:  2006-09       Impact factor: 2.512

6.  Rigid internal fixation of fractures of the proximal humerus in older patients.

Authors:  B Hintermann; H H Trouillier; D Schäfer
Journal:  J Bone Joint Surg Br       Date:  2000-11

Review 7.  Fractures of the proximal humerus in osteoporotic bone.

Authors:  Ralph Hertel
Journal:  Osteoporos Int       Date:  2004-10-30       Impact factor: 4.507

8.  Force analysis of rotator cuff muscles.

Authors:  R E Hughes; K N An
Journal:  Clin Orthop Relat Res       Date:  1996-09       Impact factor: 4.176

9.  Primary hemiarthroplasty for treatment of proximal humeral fractures.

Authors:  C Michael Robinson; Richard S Page; Richard M F Hill; David L Sanders; Charles M Court-Brown; Alison E Wakefield
Journal:  J Bone Joint Surg Am       Date:  2003-07       Impact factor: 5.284

10.  Acute prosthetic replacement for severe fractures of the proximal humerus.

Authors:  R J Hawkins; P Switlyk
Journal:  Clin Orthop Relat Res       Date:  1993-04       Impact factor: 4.176

View more
  2 in total

1.  Comparison between the spatial subchondral support plate and the proximal humeral locking plate in the treatment of unstable proximal humeral fractures.

Authors:  Fan Zhang; Lei Zhu; Di Yang; Peng Yang; Jun Ma; Qiang Fu; Aimin Chen
Journal:  Int Orthop       Date:  2015-02-26       Impact factor: 3.075

Review 2.  Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review.

Authors:  Ali Jabran; Chris Peach; Lei Ren
Journal:  Biomed Eng Online       Date:  2018-04-27       Impact factor: 2.819

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.