Literature DB >> 23563165

Resolution recovery reconstruction for a Compton camera.

Soo Mee Kim1, Hee Seo, Jin Hyung Park, Chan Hyeong Kim, Chun Sik Lee, Soo-Jin Lee, Dong Soo Lee, Jae Sung Lee.   

Abstract

The spatial resolution from Compton cameras suffers from measurement uncertainties in interaction positions and energies. The degree of degradation in spatial resolution is shift-variant (SV) over the field-of-view (FOV) because the imaging principle is based on the conical surface integration. In our study, the shift-variant point spread function (SV-PSF) is derived from point source measurements at various positions in the FOV and is incorporated into the system matrix of a fully three-dimensional, accelerated reconstruction, i.e. the listmode ordered subset expectation maximization (LMOSEM) algorithm, for resolution recovery. Simulation data from point sources were used to estimate SV and asymmetric parameters for Gaussian, Cauchy, and general parametric PSFs. Although little difference in the fitness accuracy between Gaussian and general parametric PSFs was observed, the general parametric model showed greater flexibility over the FOV in shaping the curve between that for Gaussian and Cauchy functions. The estimated asymmetric SV-PSFs were incorporated into the LMOSEM for resolution recovery. For simulation data from a single point source at the origin, all LMOSEM-SV-PSFs improved the spatial resolution by 2.6 times over the standard LMOSEM. For two point-source simulations, reconstructions also gave a two-fold improvement in spatial resolution and resulted in a greater recovered activity ratio at different positions in the FOV.

Entities:  

Mesh:

Year:  2013        PMID: 23563165     DOI: 10.1088/0031-9155/58/9/2823

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Resolution recovery for Compton camera using origin ensemble algorithm.

Authors:  A Andreyev; A Celler; I Ozsahin; A Sitek
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

Review 2.  Compton imaging for medical applications.

Authors:  Hideaki Tashima; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2022-07-22

3.  3D prompt gamma imaging for proton beam range verification.

Authors:  E Draeger; D Mackin; S Peterson; H Chen; S Avery; S Beddar; J C Polf
Journal:  Phys Med Biol       Date:  2018-01-30       Impact factor: 3.609

4.  FPGA-Based Interface of Digital DAQ System for Double-Scattering Compton Camera.

Authors:  Soo Mee Kim; Young Soo Kim
Journal:  Nucl Med Mol Imaging       Date:  2018-10-25

5.  Compton-based prompt gamma imaging using ordered origin ensemble algorithm with resolution recovery in proton therapy.

Authors:  Zhiyang Yao; Yongshun Xiao; Zhiqiang Chen; Bo Wang; Qinhan Hou
Journal:  Sci Rep       Date:  2019-02-04       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.