Literature DB >> 23562053

The impact of chronic blood-brain barrier breach on intracortical electrode function.

Tarun Saxena1, Lohitash Karumbaiah, Eric A Gaupp, Radhika Patkar, Ketki Patil, Martha Betancur, Garrett B Stanley, Ravi V Bellamkonda.   

Abstract

Brain-computer interfaces (BCIs) have allowed control of prosthetic limbs in paralyzed patients. Unfortunately, the electrodes of the BCI that interface with the brain only function for a short period of time before the signal quality on these electrodes becomes substantially diminished. To truly realize the potential of BCIs, it is imperative to have electrodes that function chronically. In order to elucidate the physiological determinants of a chronically functional neural interface, we studied the role of the blood-brain barrier (BBB) in electrode function, because it is a key mediator of neuronal hemostasis. We monitored the status of the BBB and the consequences of BBB breach on electrode function using non-invasive imaging, electrophysiology, genomic, and histological analyses. Rats implanted with commercially available intracortical electrodes demonstrated an inverse correlation between electrode performance and BBB breach over a period of 16 weeks. Genomic analysis showed that chronically functional electrodes elicit an enhanced wound healing response. Conversely, in poorly functioning electrodes, chronic BBB breach led to local accumulation of neurotoxic factors and an influx of pro-inflammatory myeloid cells, which negatively affect neuronal health. These findings were further verified in a subset of electrodes with graded electrophysiological performance. In this study, we determine the mechanistic link between intracortical electrode function and failure. Our results indicate that BBB status is a critical physiological determinant of intracortical electrode function and can inform future electrode design and biochemical intervention strategies to enhance the functional longevity of BCIs.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23562053     DOI: 10.1016/j.biomaterials.2013.03.007

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  104 in total

1.  Implantable electronics: A sensor web for neurons.

Authors:  Tarun Saxena; Ravi V Bellamkonda
Journal:  Nat Mater       Date:  2015-12       Impact factor: 43.841

2.  Minimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activity.

Authors:  Thomas J Oxley; Nicholas L Opie; Sam E John; Gil S Rind; Stephen M Ronayne; Tracey L Wheeler; Jack W Judy; Alan J McDonald; Anthony Dornom; Timothy J H Lovell; Christopher Steward; David J Garrett; Bradford A Moffat; Elaine H Lui; Nawaf Yassi; Bruce C V Campbell; Yan T Wong; Kate E Fox; Ewan S Nurse; Iwan E Bennett; Sébastien H Bauquier; Kishan A Liyanage; Nicole R van der Nagel; Piero Perucca; Arman Ahnood; Katherine P Gill; Bernard Yan; Leonid Churilov; Christopher R French; Patricia M Desmond; Malcolm K Horne; Lynette Kiers; Steven Prawer; Stephen M Davis; Anthony N Burkitt; Peter J Mitchell; David B Grayden; Clive N May; Terence J O'Brien
Journal:  Nat Biotechnol       Date:  2016-02-08       Impact factor: 54.908

3.  Glial responses to implanted electrodes in the brain.

Authors:  Joseph W Salatino; Kip A Ludwig; Takashi D Y Kozai; Erin K Purcell
Journal:  Nat Biomed Eng       Date:  2017-11-10       Impact factor: 25.671

4.  Compliant intracortical implants reduce strains and strain rates in brain tissue in vivo.

Authors:  Arati Sridharan; Jessica K Nguyen; Jeffrey R Capadona; Jit Muthuswamy
Journal:  J Neural Eng       Date:  2015-04-02       Impact factor: 5.379

5.  Histological evaluation of a chronically-implanted electrocorticographic electrode grid in a non-human primate.

Authors:  Alan D Degenhart; James Eles; Richard Dum; Jessica L Mischel; Ivan Smalianchuk; Bridget Endler; Robin C Ashmore; Elizabeth C Tyler-Kabara; Nicholas G Hatsopoulos; Wei Wang; Aaron P Batista; X Tracy Cui
Journal:  J Neural Eng       Date:  2016-06-28       Impact factor: 5.379

6.  Inhibition of the cluster of differentiation 14 innate immunity pathway with IAXO-101 improves chronic microelectrode performance.

Authors:  John K Hermann; Madhumitha Ravikumar; Andrew J Shoffstall; Evon S Ereifej; Kyle M Kovach; Jeremy Chang; Arielle Soffer; Chun Wong; Vishnupriya Srivastava; Patrick Smith; Grace Protasiewicz; Jingle Jiang; Stephen M Selkirk; Robert H Miller; Steven Sidik; Nicholas P Ziats; Dawn M Taylor; Jeffrey R Capadona
Journal:  J Neural Eng       Date:  2018-04       Impact factor: 5.379

7.  The Effect of Residual Endotoxin Contamination on the Neuroinflammatory Response to Sterilized Intracortical Microelectrodes.

Authors:  Madhumitha Ravikumar; Daniel J Hageman; William H Tomaszewski; Gabriella M Chandra; John L Skousen; Jeffrey R Capadona
Journal:  J Mater Chem B       Date:  2014-05-07       Impact factor: 6.331

8.  Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates.

Authors:  James C Barrese; Naveen Rao; Kaivon Paroo; Corey Triebwasser; Carlos Vargas-Irwin; Lachlan Franquemont; John P Donoghue
Journal:  J Neural Eng       Date:  2013-11-12       Impact factor: 5.379

9.  Neuroadhesive protein coating improves the chronic performance of neuroelectronics in mouse brain.

Authors:  Asiyeh Golabchi; Kevin M Woeppel; Xia Li; Carl F Lagenaur; X Tracy Cui
Journal:  Biosens Bioelectron       Date:  2020-02-18       Impact factor: 10.618

10.  An approach for long-term, multi-probe Neuropixels recordings in unrestrained rats.

Authors:  Thomas Zhihao Luo; Adrian Gopnik Bondy; Diksha Gupta; Verity Alexander Elliott; Charles D Kopec; Carlos D Brody
Journal:  Elife       Date:  2020-10-22       Impact factor: 8.140

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.