Clinical evaluation of a wireless ECG sensor system for arrhythmia diagnostic purposes.

Rune Fensli1, Torstein Gundersen, Tormod Snaprud, Ole Hejlesen.   

Abstract

In a clinical study, a novel wireless electrocardiogram (ECG) recorder has been evaluated with regard to its ability to perform arrhythmia diagnostics. As the ECG recorder will detect a "non-standard" ECG signal, it has been necessary to compare those signals to "standard" ECG recording signals in order to evaluate the arrhythmia detection ability of the new system. Simultaneous recording of ECG signals from both the new wireless ECG recorder and a conventional Holter recorder was compared by two independent cardiology specialists with regard to signal quality for performing arrhythmia diagnosis. In addition, calculated R-R intervals from the two systems were correlated. A total number of 16 patients participated in the study. It can be considered that recorded ECG signals obtained from the wireless ECG system had an acceptable quality for arrhythmia diagnosis. Some of the patients used the wireless sensor while doing physical sport activities, and the quality of the recorded ECG signals made it possible to perform arrhythmia diagnostics even under such conditions. Consequently, this makes possible improvements in correlating arrhythmias to physical activities.
Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23561922     DOI: 10.1016/j.medengphy.2013.03.002

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  4 in total

1.  The early-onset febrile reaction following vaccination and associated factors: An exploratory sub-study based on the Ebola vaccine clinical trial.

Authors:  Qigang Dai; Qi Liang; Yuemei Hu; Fanyue Meng; Jingxin Li; Lihua Hou; Hailong Zhou; Kai Chu; Xiaokui Hu; Rong Tang; Wenjuan Wang; Jialei Hu; Haodi Huang; Zhen Li; Shuqi Yang; Fengcai Zhu
Journal:  Hum Vaccin Immunother       Date:  2017-02-22       Impact factor: 3.452

2.  Smart multi-level tool for remote patient monitoring based on a wireless sensor network and mobile augmented reality.

Authors:  Fernando Cornelio Jiménez González; Osslan Osiris Vergara Villegas; Dulce Esperanza Torres Ramírez; Vianey Guadalupe Cruz Sánchez; Humberto Ochoa Domínguez
Journal:  Sensors (Basel)       Date:  2014-09-16       Impact factor: 3.576

3.  Prevalence of unknown and untreated arrhythmias in an older outpatient population screened by wireless long-term recording ECG.

Authors:  Terese Lindberg; Doris M Bohman; Sölve Elmståhl; Claes Jogréus; Johan Sanmartin Berglund
Journal:  Clin Interv Aging       Date:  2016-08-10       Impact factor: 4.458

Review 4.  ECG Monitoring Systems: Review, Architecture, Processes, and Key Challenges.

Authors:  Mohamed Adel Serhani; Hadeel T El Kassabi; Heba Ismail; Alramzana Nujum Navaz
Journal:  Sensors (Basel)       Date:  2020-03-24       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.