Literature DB >> 23559901

Dosimetric Consistency of Co-60 Teletherapy Unit- a ten years Study.

Misba H Baba, M Mohib-Ul-Haq, Aijaz A Khan.   

Abstract

OBJECTIVE: The goal of the Radiation standards and Dosimetry is to ensure that the output of the Teletherapy Unit is within ±2% of the stated one and the output of the treatment dose calculation methods are within ±5%. In the present paper, we studied the dosimetry of Cobalt-60 (Co-60) Teletherapy unit at Sher-I-Kashmir Institute of Medical Sciences (SKIMS) for last 10 years. Radioactivity is the phenomenon of disintegration of unstable nuclides called radionuclides. Among these radionuclides, Cobalt-60, incorporated in Telecobalt Unit, is commonly used in therapeutic treatment of cancer. Cobalt-60 being unstable decays continuously into Ni-60 with half life of 5.27 years thereby resulting in the decrease in its activity, hence dose rate (output). It is, therefore, mandatory to measure the dose rate of the Cobalt-60 source regularly so that the patient receives the same dose every time as prescribed by the radiation oncologist. The under dosage may lead to unsatisfactory treatment of cancer and over dosage may cause radiation hazards. Our study emphasizes the consistency between actual output and output obtained using decay method.
METHODOLOGY: The methodology involved in the present study is the calculations of actual dose rate of Co-60 Teletherapy Unit by two techniques i.e. Source to Surface Distance (SSD) and Source to Axis Distance (SAD), used for the External Beam Radiotherapy, of various cancers, using the standard methods. Thereby, a year wise comparison has been made between average actual dosimetric output (dose rate) and the average expected output values (obtained by using decay method for Co-60.).
RESULTS: The present study shows that there is a consistency in the average output (dose rate) obtained by the actual dosimetry values and the expected output values obtained using decay method. The values obtained by actual dosimetry are within ±2% of the expected values.
CONCLUSION: The results thus obtained in a year wise comparison of average output by actual dosimetry done regularly as a part of Quality Assurance of the Telecobalt Radiotherapy Unit and its deviation from the expected output data is within the permissible limits. Thus our study shows a trend towards uniformity and a better dose delivery.

Entities:  

Keywords:  AAPM; Consistency; Dose; Dosimetry; Output; Teletherapy

Year:  2013        PMID: 23559901      PMCID: PMC3612411          DOI: 10.12816/0006016

Source DB:  PubMed          Journal:  Int J Health Sci (Qassim)        ISSN: 1658-3639


  5 in total

1.  Quality assurance in external beam radiation therapy.

Authors:  G K Svensson
Journal:  Radiographics       Date:  1989-01       Impact factor: 5.333

2.  A code of practice for the dosimetry of 2 to 35 MV x-ray and caesium-137 and cobalt-60 gamma-ray beams.

Authors: 
Journal:  Phys Med Biol       Date:  1969-01       Impact factor: 3.609

3.  A protocol for the determination of absorbed dose from high-energy photon and electron beams.

Authors: 
Journal:  Med Phys       Date:  1983 Nov-Dec       Impact factor: 4.071

4.  Use of a Victoreen 500 electrometer to determine ionization chamber collection efficiencies.

Authors:  P R Almond
Journal:  Med Phys       Date:  1981 Nov-Dec       Impact factor: 4.071

5.  Protocol for the dosimetry of x- and gamma-ray beams with maxi um energies between 0-6 and 50 MeV. Scientific Committee on Radiation Dosimetry (SCRAD) of the American Association of Physicists in Medicine.

Authors: 
Journal:  Phys Med Biol       Date:  1971-07       Impact factor: 3.609

  5 in total
  3 in total

1.  Radiosensitization of Hs-766T Pancreatic Tumor Xenografts in Mice Dosed with Dodecafluoropentane Nano-Emulsion-Preliminary Findings.

Authors:  Jennifer L H Johnson; Rafael A Leos; Amanda F Baker; Evan C Unger
Journal:  J Biomed Nanotechnol       Date:  2015-02       Impact factor: 4.099

2.  In vitro quality assurance of three-dimensional conformal radiotherapy mono-isocentric plan for simultaneous treatment of two targets.

Authors:  Misba Hamid Baba; Benoy Kumar Singh
Journal:  Int J Health Sci (Qassim)       Date:  2022 Jan-Feb

3.  A simple method to prolong the service life of radioactive sources for external radiotherapy.

Authors:  Yingjie Xu; Yuan Tian; Jianrong Dai
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.