The Use of Enclose(®)II Anastomosis Assist Device for the Proximal Coronary Branch Anastomosis to Vascular Graft.

Keita Kikuchi1, Keiichi Tambara, Taira Yamamoto, Motoshige Yamasaki, Hitoshi Hirose, Atsushi Amano.   

Abstract

We used the Enclose(®)II anastomosis assist device (Novare Surgical Systems, Inc., CA, USA), which was originally developed as an ancillary device for proximal anastomosis in off-pump coronary artery bypass grafting (OPCAB), to assist anastomosis for the vascular grafts without clamping those conduits in two cases. In these cases, it was difficult to clump vascular graft partially, because vascular graft was short. So we used Enclose(®)II anastomosis assist device for these cases. The advantage of this method is that the Enclose(®)II anastomosis assist device facilitates the anastomosis of arterial side branches to the artificial graft (1) by eliminating the use of partial clamp on the artificial conduits and (2) by providing a plane surface for easy handling for suture.

Entities:  

Keywords:  CABG (coronary artery bypass grafting); Enclose®II anastomosis assist device; vascular graft

Year:  2010        PMID: 23555395      PMCID: PMC3595814          DOI: 10.3400/avd.AVDhdi08023

Source DB:  PubMed          Journal:  Ann Vasc Dis        ISSN: 1881-641X


  4 in total

1.  Initial experience with the enclose proximal aortic anastomosis device during off-pump coronary artery bypass: an alternative to aortic side clamping.

Authors:  Robert S Boova; Candace Trace; Bradley G Leshnower
Journal:  Heart Surg Forum       Date:  2006       Impact factor: 0.676

2.  Evaluation of the enclose proximal anastomosis device in coronary artery bypass grafting.

Authors:  Sary F Aranki; Prem S Shekar; Afshin Ehsan; Margaretta Byrne-Taft; Gregory S Couper
Journal:  Ann Thorac Surg       Date:  2005-09       Impact factor: 4.330

3.  First clinical experience with the HEARTSTRING, a device for proximal anastomoses in coronary surgery.

Authors:  Calin Vicol; Martin Oberhoffer; Georg Nollert; Sandra Eifert; Peter Boekstegers; Bernd Wintersperger; Bruno Reichart
Journal:  Ann Thorac Surg       Date:  2005-05       Impact factor: 4.330

4.  Clinical experience with the Novare Enclose II manual proximal anastomotic device during off-pump coronary artery surgery.

Authors:  Belhhan Akpinar; Mustafa Guden; Ertan Sagbas; Ilhan Sanisoglu; Mehmet U Ergenoğlu; Cavlan Turkoglu
Journal:  Eur J Cardiothorac Surg       Date:  2005-04-09       Impact factor: 4.191

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.