Literature DB >> 15896619

Clinical experience with the Novare Enclose II manual proximal anastomotic device during off-pump coronary artery surgery.

Belhhan Akpinar1, Mustafa Guden, Ertan Sagbas, Ilhan Sanisoglu, Mehmet U Ergenoğlu, Cavlan Turkoglu.   

Abstract

OBJECTIVE: The aim of this study was to assess the feasibility and safety of a new proximal anastomotic device during off-pump coronary surgery.
METHODS: The Novare Enclose II is a manual proximal anastomotic device that enables the surgeon to perform proximal anastomoses without side-biting clamps in a fully pressurized aorta. The device was used in 30 off-pump coronary artery bypass graft (CABG) patients (Group A) for performing 25 vein, 10 free right internal thoracic artery and 14 radial artery anastomoses to the aorta. The number of proximal anastomoses varied between 1 and 3 per patient. Intraoperative transcranial Doppler measurements were performed to detect cerebral microemboli during the use of the device and were compared with transcranial Doppler measurements of 30 off-pump patients where a partial side clamp was used for proximal anastomoses (Group B). The aorta was evaluated using transesophageal echocardiography (TEE) and epiaortic echocardiography (EAE) in both groups before the procedure and patients with a calcified aorta were excluded.
RESULTS: In Group A, 49 proximal anostomoses were performed as planned with the device using conventional hand-sewn methods. Twenty-four of these were arterial conduits. In Group B, 32 proximal anastomoses were performed using 25 veins and 7 arterial grafts. There were no procedure related to adverse events or complications in both groups. The median number of microemboli was 15 (range 5-48) in Group A and 68 (range 35-290) in Group B (P<0.05).
CONCLUSION: The Enclose II device can be a valuable tool to perform venous or arterial proximal anastomoses during off-pump CABG. Transcranial Doppler results suggest that the device seems to be less traumatizing than side clamping and may reduce clamp-associated complications during off-pump coronary artery surgery.

Entities:  

Mesh:

Year:  2005        PMID: 15896619     DOI: 10.1016/j.ejcts.2005.02.041

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  5 in total

1.  Use of an aortic connector system for vein grafting: intermediate outcomes.

Authors:  Hirotaka Inaba; Kazuhiko Higuchi; Kenji Koseni; Haruo Yamauchi; Junichi Naganuma
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2005-11

2.  The Use of Enclose(®)II Anastomosis Assist Device for the Proximal Coronary Branch Anastomosis to Vascular Graft.

Authors:  Keita Kikuchi; Keiichi Tambara; Taira Yamamoto; Motoshige Yamasaki; Hitoshi Hirose; Atsushi Amano
Journal:  Ann Vasc Dis       Date:  2010-07-21

3.  Off-pump coronary artery bypass grafting with an aortic nonclamping technique may reduce the incidence of cerebral complications.

Authors:  Hiroshi Osawa; Hirotaka Inaba; Osamu Kinoshita; Okihiko Akashi; Sachito Minegishi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2011-10-08

4.  Initial clinical experience with the Heartstring.

Authors:  Toshinobu Kazui; Hirosato Doi; Masato Suzuki; Takashi Okamoto; Ryuji Koshima; Kenji Sugiki; Takemi Ohno
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2006-10

5.  New device for saphenous vein-to-aorta proximal anastomosis without side-clamping.

Authors:  Ernesto Tappainer
Journal:  J Cardiothorac Surg       Date:  2007-05-04       Impact factor: 1.637

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.