Rahel Heule1, Carl Ganter, Oliver Bieri. 1. Division of Radiological Physics, Department of Radiology, University of Basel Hospital, Basel, Switzerland.
Abstract
PURPOSE: Rapid imaging techniques have attracted increased interest for relaxometry, but none are perfect: they are prone to static (B0 ) and transmit (B1 ) field heterogeneities, and commonly biased by T2 /T1 . The purpose of this study is the development of a rapid T1 and T2 relaxometry method that is completely (T2 ) or partly (T1 ) bias-free. METHODS: A new method is introduced to simultaneously quantify T1 and T2 within one single scan based on a triple echo steady-state (TESS) approach in combination with an iterative golden section search. TESS relaxometry is optimized and evaluated from simulations, in vitro studies, and in vivo experiments. RESULTS: It is found that relaxometry with TESS is not biased by T2 /T1 , insensitive to B0 heterogeneities, and, surprisingly, that TESS-T2 is not affected by B1 field errors. Consequently, excellent correspondence between TESS and reference spin echo data is observed for T2 in vitro at 1.5 T and in vivo at 3 T. CONCLUSION: TESS offers rapid T1 and T2 quantification within one single scan, and in particular B1 -insensitive T2 estimation. As a result, the new proposed method is of high interest for fast and reliable high-resolution T2 mapping, especially of the musculoskeletal system at high to ultra-high fields.
PURPOSE: Rapid imaging techniques have attracted increased interest for relaxometry, but none are perfect: they are prone to static (B0 ) and transmit (B1 ) field heterogeneities, and commonly biased by T2 /T1 . The purpose of this study is the development of a rapid T1 and T2 relaxometry method that is completely (T2 ) or partly (T1 ) bias-free. METHODS: A new method is introduced to simultaneously quantify T1 and T2 within one single scan based on a triple echo steady-state (TESS) approach in combination with an iterative golden section search. TESS relaxometry is optimized and evaluated from simulations, in vitro studies, and in vivo experiments. RESULTS: It is found that relaxometry with TESS is not biased by T2 /T1 , insensitive to B0 heterogeneities, and, surprisingly, that TESS-T2 is not affected by B1 field errors. Consequently, excellent correspondence between TESS and reference spin echo data is observed for T2 in vitro at 1.5 T and in vivo at 3 T. CONCLUSION: TESS offers rapid T1 and T2 quantification within one single scan, and in particular B1 -insensitive T2 estimation. As a result, the new proposed method is of high interest for fast and reliable high-resolution T2 mapping, especially of the musculoskeletal system at high to ultra-high fields.
Authors: Pierre G Carlier; Benjamin Marty; Olivier Scheidegger; Paulo Loureiro de Sousa; Pierre-Yves Baudin; Eduard Snezhko; Dmitry Vlodavets Journal: J Neuromuscul Dis Date: 2016-03-03
Authors: Markus M Schreiner; Vladimir Mlynarik; Štefan Zbýň; Pavol Szomolanyi; Sebastian Apprich; Reinhard Windhager; Siegfried Trattnig Journal: Cartilage Date: 2016-03-03 Impact factor: 4.634
Authors: Oliver Kraff; Andrea Lazik-Palm; Rahel Heule; Jens M Theysohn; Oliver Bieri; Harald H Quick Journal: MAGMA Date: 2016-04-25 Impact factor: 2.310