Literature DB >> 23553925

Needle puncture injury causes acute and long-term mechanical deficiency in a mouse model of intervertebral disc degeneration.

John T Martin1, Deborah J Gorth, Elizabeth E Beattie, Brian D Harfe, Lachlan J Smith, Dawn M Elliott.   

Abstract

Low back pain is a significant socioeconomic burden and intervertebral disc degeneration has been implicated as a cause. A reliable animal model of disc degeneration is necessary to evaluate therapeutics, and functional metrics are essential to quantify their benefit. To this end, needle puncture injuries were created in the caudal intervertebral discs of mice to induce disc degeneration. Compression, torsion, and creep mechanics were assessed both immediately and after eight weeks to distinguish between the effects of injury and the subsequent reparative or degenerative response. Two needle sizes (29 and 26 gauge) were used to determine injury size-dependence. Compressive stiffness (62%), torsional stiffness (60%), and early damping stiffness (84%) decreased immediately after injury with the large needle (26G). These mechanical properties did not change over time despite structural and compositional changes. At 8 weeks following large needle injury, disc height decreased (37%), nucleus pulposus (NP) glycosaminoglycan content decreased (41%), and NP collagen content increased (45%). The small needle size had no significant effect on mechanics and did not initiate degenerative changes in structure and composition. Thus, the injection of therapeutics into the NP with a minimal needle size may limit damage due to the needle insertion. These findings, along with the wide commercial availability of mouse-specific biological probes, indicate that the mouse caudal disc model can be a powerful tool for investigating disc degeneration and therapy.
Copyright © 2013 Orthopaedic Research Society.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23553925      PMCID: PMC6684036          DOI: 10.1002/jor.22355

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  54 in total

1.  Translation of an injectable triple-interpenetrating-network hydrogel for intervertebral disc regeneration in a goat model.

Authors:  Sarah E Gullbrand; Thomas P Schaer; Prateek Agarwal; Justin R Bendigo; George R Dodge; Weiliam Chen; Dawn M Elliott; Robert L Mauck; Neil R Malhotra; Lachlan J Smith
Journal:  Acta Biomater       Date:  2017-07-19       Impact factor: 8.947

2.  Biomechanical test protocols to detect minor injury effects in intervertebral discs.

Authors:  Olivia M Torre; Thomas W Evashwick-Rogler; Phillip Nasser; James C Iatridis
Journal:  J Mech Behav Biomed Mater       Date:  2019-03-29

3.  Translation of an engineered nanofibrous disc-like angle-ply structure for intervertebral disc replacement in a small animal model.

Authors:  John T Martin; Andrew H Milby; Joseph A Chiaro; Dong Hwa Kim; Nader M Hebela; Lachlan J Smith; Dawn M Elliott; Robert L Mauck
Journal:  Acta Biomater       Date:  2014-02-20       Impact factor: 8.947

Review 4.  Disc cell therapies: critical issues.

Authors:  Marta Tibiletti; Nevenka Kregar Velikonja; Jill P G Urban; Jeremy C T Fairbank
Journal:  Eur Spine J       Date:  2014-02-08       Impact factor: 3.134

Review 5.  Cell therapy for the degenerating intervertebral disc.

Authors:  Wei Tong; Zhouyu Lu; Ling Qin; Robert L Mauck; Harvey E Smith; Lachlan J Smith; Neil R Malhotra; Martin F Heyworth; Franklin Caldera; Motomi Enomoto-Iwamoto; Yejia Zhang
Journal:  Transl Res       Date:  2016-11-28       Impact factor: 7.012

6.  Intervertebral Disc Degeneration in a Percutaneous Mouse Tail Injury Model.

Authors:  Zuozhen Tian; Xiaoyuan Ma; Miersalijiang Yasen; Robert L Mauck; Ling Qin; Frances S Shofer; Lachlan J Smith; Maurizio Pacifici; Motomi Enomoto-Iwamoto; Yejia Zhang
Journal:  Am J Phys Med Rehabil       Date:  2018-03       Impact factor: 2.159

7.  Age-related reduction in the expression of FOXO transcription factors and correlations with intervertebral disc degeneration.

Authors:  Oscar Alvarez-Garcia; Tokio Matsuzaki; Merissa Olmer; Koichi Masuda; Martin K Lotz
Journal:  J Orthop Res       Date:  2017-05-04       Impact factor: 3.494

8.  A large animal model that recapitulates the spectrum of human intervertebral disc degeneration.

Authors:  S E Gullbrand; N R Malhotra; T P Schaer; Z Zawacki; J T Martin; J R Bendigo; A H Milby; G R Dodge; E J Vresilovic; D M Elliott; R L Mauck; L J Smith
Journal:  Osteoarthritis Cartilage       Date:  2016-08-26       Impact factor: 6.576

9.  Validation and application of an intervertebral disc finite element model utilizing independently constructed tissue-level constitutive formulations that are nonlinear, anisotropic, and time-dependent.

Authors:  Nathan T Jacobs; Daniel H Cortes; John M Peloquin; Edward J Vresilovic; Dawn M Elliott
Journal:  J Biomech       Date:  2014-06-17       Impact factor: 2.712

10.  Influence of Genetic Background and Sex on Gene Expression in the Mouse (Mus musculus) Tail in a Model of Intervertebral Disc Injury.

Authors:  Julie M Brent; Zuozhen Tian; Frances S Shofer; John T Martin; Lutian Yao; Christian Acharte; Youhai H Chen; Ling Qin; Motomi Enomoto-Iwamoto; Yejia Zhang
Journal:  Comp Med       Date:  2020-03-10       Impact factor: 0.982

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.