Literature DB >> 2355372

Intraoperative testing of anastomotic integrity after stapled anterior resection for cancer.

C D Griffith1, J D Hardcastle.   

Abstract

Sixty consecutive patients undergoing anterior restorative resection of the rectum for cancer were studied. After full mechanical bowel preparation and intravenous antibiotic prophylaxis, colorectal anastomosis was performed with the EEA (Autosuture) staple gun. The median height of the anastomosis above the anal verge was 9 cm (range 3-15 cm) and no patient had a protecting colostomy fashioned. All 'doughnuts' were checked and following instillation of saline into the pelvis the anastomosis was tested by air insufflation through the rectum. There was a statistically significant association between an incomplete 'doughnut' and peroperative anastomotic leakage (P less than 0.001); however, of the 11 patients shown to have a leak, only seven had deficient 'doughnuts'. All 11 patients had repair of the defect identified by escape of air and none of these patients developed a clinical leak.

Entities:  

Mesh:

Year:  1990        PMID: 2355372

Source DB:  PubMed          Journal:  J R Coll Surg Edinb        ISSN: 0035-8835


  9 in total

1.  Endoscopic intraoperative anastomotic testing may avoid early gastrointestinal anastomotic complications. A prospective study.

Authors:  Eva Lieto; Michele Orditura; Paolo Castellano; Margherita Pinto; Anna Zamboli; Ferdinando De Vita; Carlo Pignatelli; Gennaro Galizia
Journal:  J Gastrointest Surg       Date:  2011-01       Impact factor: 3.452

2.  Intraoperative air leak test reduces the rate of postoperative anastomotic leak: analysis of 777 laparoscopic left-sided colon resections.

Authors:  Marco Ettore Allaix; Adriana Lena; Maurizio Degiuli; Alberto Arezzo; Roberto Passera; Massimiliano Mistrangelo; Mario Morino
Journal:  Surg Endosc       Date:  2018-09-10       Impact factor: 4.584

Review 3.  Prediction and diagnosis of colorectal anastomotic leakage: A systematic review of literature.

Authors:  Freek Daams; Zhouqiao Wu; Max Jef Lahaye; Johannus Jeekel; Johan Frederik Lange
Journal:  World J Gastrointest Surg       Date:  2014-02-27

4.  Routine leak testing in colorectal surgery in the Surgical Care and Outcomes Assessment Program.

Authors:  Steve Kwon; Arden Morris; Richard Billingham; Joseph Frankhouse; Karen Horvath; Morrie Johnson; Shane McNevin; Anthony Simons; Rebecca Symons; Scott Steele; Richard Thirlby; Mark Whiteford; David R Flum
Journal:  Arch Surg       Date:  2012-04

Review 5.  Intraoperative assessment of colorectal anastomotic integrity: a systematic review.

Authors:  Subramanian Nachiappan; Alan Askari; Andrew Currie; Robin H Kennedy; Omar Faiz
Journal:  Surg Endosc       Date:  2014-04-10       Impact factor: 4.584

6.  Intraoperative evaluation of colorectal anastomotic integrity: a comparison of air leak and dye leak tests.

Authors:  Y Rudnicki; I White; V Tiomkin; L Lahav; B Raguan; S Avital
Journal:  Tech Coloproctol       Date:  2021-04-27       Impact factor: 3.781

7.  The small height of an anastomotic colonic doughnut is an independent risk factor of anastomotic leakage following colorectal resection: results of a prospective study on 154 consecutive cases.

Authors:  François Cauchy; Solafah Abdalla; Christophe Penna; Benjamin Angliviel; Benoit Lambert; Bruno Costaglioli; Antoine Brouquet; Stéphane Benoist
Journal:  Int J Colorectal Dis       Date:  2017-01-26       Impact factor: 2.571

8.  The efficacy of intraoperative methylene blue enemas to assess the integrity of a colonic anastomosis.

Authors:  Stanton Smith; William McGeehin; Robert A Kozol; David Giles
Journal:  BMC Surg       Date:  2007-08-02       Impact factor: 2.102

Review 9.  Is the intraoperative air leak test effective in the prevention of colorectal anastomotic leakage? A systematic review and meta-analysis.

Authors:  Zhouqiao Wu; Remondus C J van de Haar; Cloë L Sparreboom; Geesien S A Boersema; Ziyu Li; Jiafu Ji; Johannes Jeekel; Johan F Lange
Journal:  Int J Colorectal Dis       Date:  2016-06-13       Impact factor: 2.571

  9 in total