Literature DB >> 23551656

Fine needle aspiration cytology of nodular thyroid lesions: a 2-year experience of the Bethesda system for reporting thyroid cytopathology in a large regional and a university hospital, with histological correlation.

E Mastorakis1, C Meristoudis, N Margari, A Pouliakis, K Leventakos, N Chroniaris, I Panayiotides, P Karakitsos.   

Abstract

OBJECTIVE: Thyroid fine needle aspiration (FNA) contributes to the appropriate management of nodular thyroid lesions. The introduced categories in the Bethesda system for reporting thyroid cytopathology (TBSRTC) are associated with an implied cancer risk, providing a clinical management guideline. This study aims to evaluate the reproducibility of this implied risk and to compare the results from two different cytopathology departments.
METHODS: Five hundred histologically confirmed FNAs, studied since the introduction of TBSRTC, were obtained from 4208 and 3587 FNAs performed in a large regional hospital in Herakleion, Crete (group A) and a university hospital in Athens (group B), respectively. Reports were issued according to TBSRTC. Aspirates were prepared with ThinPrep(®) and evaluated by two experienced cytopathologists. The reproducibility and accuracy were evaluated.
RESULTS: The proportion test for suspicious for malignancy (SFM) and malignant (M) cytology reports (P < 0.0001), and the number of malignancies on histology (P < 0.0001), were significantly higher in group A than in group B, consistent with a higher incidence of thyroid carcinomas in southern Greece. Although the malignancy rates were higher in group A than in group B for all categories, except M (A, 99.3%; B, 100%), the difference was only significant for benign aspirates (P = 0.0303). Malignancy rates for all categories in group A were above the TBSRTC recommended range, but were consistent with an increased prevalence of malignancy in that centre, differences in reporting practice and the variable ranges reported in the literature. There was lower sensitivity (P = 0.019) and overall accuracy (P = 0.003) in group A relative to group B, but no difference in specificity.
CONCLUSIONS: TBSRTC provides valuable information for the appropriate management of nodular thyroid lesions, both in a university and a large regional hospital.
© 2013 John Wiley & Sons Ltd.

Entities:  

Keywords:  fine needle aspiration; liquid-based cytology; reproducibility; risk of malignancy; the Bethesda system for reporting thyroid cytopathology; thyroid

Mesh:

Year:  2013        PMID: 23551656     DOI: 10.1111/cyt.12062

Source DB:  PubMed          Journal:  Cytopathology        ISSN: 0956-5507            Impact factor:   2.073


  5 in total

1.  Radial Basis Function Artificial Neural Network for the Investigation of Thyroid Cytological Lesions.

Authors:  Christos Fragopoulos; Abraham Pouliakis; Christos Meristoudis; Emmanouil Mastorakis; Niki Margari; Nicolaos Chroniaris; Nektarios Koufopoulos; Alexander G Delides; Nicolaos Machairas; Vasileia Ntomi; Konstantinos Nastos; Ioannis G Panayiotides; Emmanouil Pikoulis; Evangelos P Misiakos
Journal:  J Thyroid Res       Date:  2020-11-24

2.  Fine needle aspiration biopsy of thyroid nodules: cytologic and histopathologic correlation of 1096 patients.

Authors:  Ceyhan Ugurluoglu; Fatma Dobur; Pinar Karabagli; Zeliha Esin Celik
Journal:  Int J Clin Exp Pathol       Date:  2015-11-01

3.  Malignancy rates for Bethesda III subcategories in thyroid fine needle aspiration biopsy (FNAB).

Authors:  Leticia Mosca; Luiz Fernando Ferraz da Silva; Paulo Campos Carneiro; Danielle Azevedo Chacon; Vergilius Jose Furtado de Araujo-Neto; Vergilius Jose Furtado de Araujo-Filho; Claudio Roberto Cernea
Journal:  Clinics (Sao Paulo)       Date:  2018-05-28       Impact factor: 2.365

4.  Diagnosis of follicular lesions of undetermined significance in fine-needle aspirations of thyroid nodules.

Authors:  J Ratour; M Polivka; H Dahan; L Hamzi; R Kania; M L Dumuis; R Cohen; M Laloi-Michelin; B Cochand-Priollet
Journal:  J Thyroid Res       Date:  2013-03-24

5.  Can liquid-based preparation substitute for conventional smear in thyroid fine-needle aspiration? A systematic review based on meta-analysis.

Authors:  Yosep Chong; Soon-Jin Ji; Chang Suk Kang; Eun Jung Lee
Journal:  Endocr Connect       Date:  2017-10-10       Impact factor: 3.335

  5 in total