Literature DB >> 23551427

Histological, radiological and histomorphometric evaluation of immediate vs. non-immediate loading of a zirconia implant with surface treatment in a dog model.

Jose L Calvo-Guirado1, Antonio Aguilar-Salvatierra, Gerardo Gomez-Moreno, Javier Guardia, Rafael A Delgado-Ruiz, Jose Eduardo Mate-Sanchez de Val.   

Abstract

OBJECTIVE: The aim of this study was to assess the performance of zirconia implants under immediate loading compared with delayed loading in dogs over 30-90 days.
MATERIALS AND METHODS: Tooth extractions were made for the subsequent placement of dental implants at premolars P2, P3, P4 and molars M1 bilaterally in the dog mandible. Forty eight zirconia implants, 4 mm in diameter and 10 mm in length, were inserted, whose neck and body surfaces had been treated with femtosecond laser texturing; 24 implants were loaded immediately and 24 remained unloaded during the osseointegration period. Final radiographs were taken recording stability values before sacrifice at 30 or 90 days when sample removal for histological and histomorphometric analysis was performed. Bone-to-implant contact, crestal bone loss and implant stability were evaluated at these two study times.
RESULTS: Bone-to-implant contact values after 30 days were 38.9% for immediately loaded implants and 32% for non-loaded implants. After 90 days, values increased to 65% for immediately loaded and 57.6% for non-loaded implants. After 30 days, there was more crestal bone lost in the non-loaded group (0.58 ± 0.28 mm) compared with the immediately loaded group (0.5 ± 0.3 mm). After 90 days, there was improved stability in both groups, but was lower in the immediately loaded group (0.5 ± 0.23 mm) compared with the non-loaded group (0.56 ± 0.28 mm). Initial implant stability values were -3.5 PTV at the moment of implant placement. Stability values after the first 30 days were -4 for immediately loaded implants and -3 for non-loaded. At 90 days, non-loaded implants showed -4.9, whereas immediately loaded showed -7.1.
CONCLUSIONS: For the different parameters studied, zirconia implants treated with femtosecond laser and subjected to immediate loading showed better results compared with non-loaded implants in terms of BIC, crestal bone loss and implant stability.
© 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

Entities:  

Keywords:  BIC; Zirconia implants; crestal bone loss; immediate loading; implant stability

Mesh:

Substances:

Year:  2013        PMID: 23551427     DOI: 10.1111/clr.12145

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  3 in total

Review 1.  Zirconia surface modifications for implant dentistry.

Authors:  Fernanda H Schünemann; María E Galárraga-Vinueza; Ricardo Magini; Márcio Fredel; Filipe Silva; Júlio C M Souza; Yu Zhang; Bruno Henriques
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2019-01-16       Impact factor: 7.328

Review 2.  Surface modification of zirconia dental implants by laser texturing.

Authors:  Welson Cunha; Oscar Carvalho; Bruno Henriques; Filipe S Silva; Mutlu Özcan; Júlio C M Souza
Journal:  Lasers Med Sci       Date:  2022-01-13       Impact factor: 3.161

Review 3.  Surface Structure of Zirconia Implants: An Integrative Review Comparing Clinical Results with Preclinical and In Vitro Data.

Authors:  Nadja Rohr; Blerta Hoda; Jens Fischer
Journal:  Materials (Basel)       Date:  2022-05-20       Impact factor: 3.748

  3 in total