Literature DB >> 23549780

Quasi-VMAT in high-grade glioma radiation therapy.

G Fadda1, G Massazza, S Zucca, S Durzu, G Meleddu, M Possanzini, P Farace.   

Abstract

PURPOSE: To compare a quasi-volumetric modulated arc therapy (qVMAT) with three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) for the treatment of high-grade gliomas. The qVMAT technique is a fast method of radiation therapy in which multiple equispaced beams analogous to those in rotation therapy are radiated in succession. PATIENTS AND METHODS: This study included 12 patients with a planning target volume (PTV) that overlapped at least one organ at risk (OAR). 3D-CRT was planned using 2-3 non-coplanar beams, whereby the field-in-field technique (FIF) was used to divide each field into 1-3 subfields to shield the OAR. The qVMAT strategy was planned with 15 equispaced beams and IMRT was planned using 9 beams with a total of 80 segments. Inverse planning for qVMAT and IMRT was performed by direct machine parameter optimization (DMPO) to deliver a homogenous dose distribution of 60 Gy within the PTV and simultaneously limit the dose received by the OARs to the recommended values. Finally, the effect of introducing a maximum dose objective (max. dose < 54 Gy) for a virtual OAR in the form of a 0.5 cm ring around the PTV was investigated.
RESULTS: The qVMAT method gave rise to significantly improved PTV95% and conformity index (CI) values in comparison to 3D-CRT (PTV95% = 90.7 % vs. 82.0 %; CI = 0.79 vs. 0.74, respectively). A further improvement was achieved by IMRT (PTV95% = 94.4 %, CI = 0.78). In qVMAT and IMRT, the addition of a 0.5 cm ring around the PTV produced a significant increase in CI (0.87 and 0.88, respectively), but dosage homogeneity within the PTV was considerably reduced (PTV95% = 88.5 % and 92.3 %, respectively). The time required for qVMAT dose delivery was similar to that required using 3D-CRT.
CONCLUSION: These findings suggest that qVMAT should be preferred to 3D-CRT for the treatment of high-grade gliomas. The qVMAT method could be applied in hospitals, for example, which have limited departmental resources and are not equipped with systems capable of VMAT delivery.

Entities:  

Mesh:

Year:  2013        PMID: 23549780     DOI: 10.1007/s00066-012-0296-8

Source DB:  PubMed          Journal:  Strahlenther Onkol        ISSN: 0179-7158            Impact factor:   3.621


  21 in total

1.  Effect of photon-beam energy on VMAT and IMRT treatment plan quality and dosimetric accuracy for advanced prostate cancer.

Authors:  Marlies Pasler; Dietmar Georg; Holger Wirtz; Johannes Lutterbach
Journal:  Strahlenther Onkol       Date:  2011-11-29       Impact factor: 3.621

2.  A phase II trial of accelerated radiotherapy using weekly stereotactic conformal boost for supratentorial glioblastoma multiforme: RTOG 0023.

Authors:  Robert Cardinale; Minhee Won; Ali Choucair; Michael Gillin; Arnab Chakravarti; Christopher Schultz; Luis Souhami; Allan Chen; Huong Pham; Minesh Mehta
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-06-05       Impact factor: 7.038

3.  Intensity-modulated radiotherapy (IMRT) and conventional three-dimensional conformal radiotherapy for high-grade gliomas: does IMRT increase the integral dose to normal brain?

Authors:  Ulrich Hermanto; Erik K Frija; Mingfwu J Lii; Eric L Chang; Anita Mahajan; Shiao Y Woo
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-01-08       Impact factor: 7.038

Review 4.  Why avoid the hippocampus? A comprehensive review.

Authors:  Vinai Gondi; Wolfgang A Tomé; Minesh P Mehta
Journal:  Radiother Oncol       Date:  2010-10-20       Impact factor: 6.280

5.  Quasi-IMAT study with conventional equipment to show high plan quality with a single gantry arc.

Authors:  Judith Alvarez Moret; Oliver Kölbl; Ludwig Bogner
Journal:  Strahlenther Onkol       Date:  2009-02-18       Impact factor: 3.621

6.  Intensity-modulated radiotherapy in high-grade gliomas: clinical and dosimetric results.

Authors:  Ashwatha Narayana; Josh Yamada; Sean Berry; Priti Shah; Margie Hunt; Philip H Gutin; Steven A Leibel
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-03-01       Impact factor: 7.038

7.  Quasi-IMAT technique and secondary cancer risk in prostate cancer.

Authors:  Judith Alvarez Moret; Oliver Koelbl; Ludwig Bogner
Journal:  Strahlenther Onkol       Date:  2009-04-16       Impact factor: 3.621

8.  Radiotherapy of malignant gliomas: comparison of volumetric single arc technique (RapidArc), dynamic intensity-modulated technique and 3D conformal technique.

Authors:  Daniela Wagner; Hans Christiansen; Hendrik Wolff; Hilke Vorwerk
Journal:  Radiother Oncol       Date:  2009-11-10       Impact factor: 6.280

9.  Comparison of intensity-modulated radiotherapy with three-dimensional conformal radiation therapy planning for glioblastoma multiforme.

Authors:  Maria F Chan; Karen Schupak; Chandra Burman; Chen-Shou Chui; C Clifton Ling
Journal:  Med Dosim       Date:  2003       Impact factor: 1.531

10.  Fast IMRT by increasing the beam number and reducing the number of segments.

Authors:  Klaus Bratengeier; Mark B Gainey; Michael Flentje
Journal:  Radiat Oncol       Date:  2011-12-09       Impact factor: 3.481

View more
  4 in total

1.  Erratum to: Evolution of educational inequalities in mortality among young adults in an urban setting.

Authors:  Hannelore De Grande; Patrick Deboosere; Hadewijch Vandenheede
Journal:  Int J Public Health       Date:  2015-03       Impact factor: 3.380

2.  Dosimetric comparison of incidental axillary irradiation between three-dimensional conformal and volumetric modulated arc techniques for breast cancer.

Authors:  In Young Jo; Eun Seog Kim; Woo Chul Kim; Chul Kee Min; Seung-Gu Yeo
Journal:  Mol Clin Oncol       Date:  2020-03-30

3.  Commissioning and first clinical application of mARC treatment.

Authors:  Yvonne Dzierma; Frank G Nuesken; Stephanie Kremp; Jan Palm; Norbert P Licht; Christian Rübe
Journal:  Strahlenther Onkol       Date:  2014-04-29       Impact factor: 3.621

4.  Optimization by visualization of indices.

Authors:  Uwe Haverkamp; Darius Norkus; Jan Kriz; Mariam Müller Minai; Franz-Josef Prott; Hans Theodor Eich
Journal:  Strahlenther Onkol       Date:  2014-06-28       Impact factor: 3.621

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.