Literature DB >> 23547279

Blood pressure measurement in peritoneal dialysis: which method is best?

Michelle M O'Shaughnessy1, Martin Durcan, Sinead M Kinsella, Matthew D Griffin, Donal N Reddan, David W Lappin.   

Abstract

BACKGROUND: The optimal approach to monitoring blood pressure (BP) in the peritoneal dialysis (PD) population is unclear. Ambulatory BP monitoring reliably predicts prognosis, but can be inconvenient. The accuracy of home BP monitoring in this population is unproven. The automated BpTRU device (BpTRU Medical Devices, Coquitlam, BC, Canada), which provides an average of up to 6 successive in-office BP measurements, has not been studied in this patient group.
METHODS: We studied 17 patients (average age: 54 ± 12 years; 12 men, 5 women; 94% on automated PD) attending a single center. All patients underwent office, home, BpTRU, and ambulatory BP measurement. The reference standard for analysis was daytime ambulatory BP. Correlation between the referent method and each comparator method was determined (Pearson correlation coefficient), and Bland-Altman scatter plots depicting the differences in the BP measurements were constructed.
RESULTS: Mean office BP (126.4 ± 16.9/78.8 ± 11.6 mmHg) and BpTRU BP (123.8 ± 13.7/80.7 ± 11.1 mmHg) closely approximated mean daytime ambulatory BP (129.3 ± 14.8/78.2 ± 7.9 mmHg). Mean home BP (143.8 ± 15.0/89.9 ± 28.1 mmHg) significantly overestimated mean daytime systolic BP by 14.2 mmHg (95% confidence interval: 4.3 mmHg to 24.1 mmHg; p = 0.008). Bland-Altman plots demonstrated poorest agreement between home BP and daytime ambulatory BP. No patient had "white-coat hypertension," and only 1 patient had false-resistant hypertension. Most patients showed abnormal nocturnal dipping patterns (non-dipping: n = 11; reverse-dipping: n = 5; normal dipping: n = 1).
CONCLUSIONS: We report a novel finding that BP measurement using the BpTRU device is more accurate than home BP measurement in a PD population. Potential explanations for this observation include poor home BP measurement technique, use of poorly validated home BP measurement devices, or a reduced prevalence of white-coat effect among PD patients. Our study also confirms that, in the PD population, BP measurements vary considerably with patient location, time of day, and measurement technique.

Entities:  

Keywords:  BpTRU; Hypertension; ambulatory; blood pressure; home; measurement

Mesh:

Year:  2013        PMID: 23547279      PMCID: PMC3797673          DOI: 10.3747/pdi.2012.00027

Source DB:  PubMed          Journal:  Perit Dial Int        ISSN: 0896-8608            Impact factor:   1.756


  19 in total

1.  Overall accuracy of the BpTRU--an automated electronic blood pressure device.

Authors:  Gurdial S Mattu; Balraj S Heran; James M Wright
Journal:  Blood Press Monit       Date:  2004-02       Impact factor: 1.444

2.  Bedtime dosing of antihypertensive medications reduces cardiovascular risk in CKD.

Authors:  Ramón C Hermida; Diana E Ayala; Artemio Mojón; José R Fernández
Journal:  J Am Soc Nephrol       Date:  2011-10-24       Impact factor: 10.121

3.  Home blood pressure measurement has a stronger predictive power for mortality than does screening blood pressure measurement: a population-based observation in Ohasama, Japan.

Authors:  T Ohkubo; Y Imai; I Tsuji; K Nagai; J Kato; N Kikuchi; A Nishiyama; A Aihara; M Sekino; M Kikuya; S Ito; H Satoh; S Hisamichi
Journal:  J Hypertens       Date:  1998-07       Impact factor: 4.844

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Blood pressure and left ventricular hypertrophy in patients on different peritoneal dialysis regimens.

Authors:  M C Wang; C C Tseng; W C Tsai; J J Huang
Journal:  Perit Dial Int       Date:  2001 Jan-Feb       Impact factor: 1.756

6.  Diurnal blood-pressure variations in haemodialysis and CAPD patients.

Authors:  A J Luik; D G Struijk; U Gladziwa; R W von Olden; J P von Hooff; P W de Leeuw; K M Leunissen
Journal:  Nephrol Dial Transplant       Date:  1994       Impact factor: 5.992

7.  How well is hypertension controlled in CAPD patients?

Authors:  J S Cheigh; D Serur; M Paguirigan; K H Stenzel; A Rubin
Journal:  Adv Perit Dial       Date:  1994

8.  Fluid status, blood pressure, and cardiovascular abnormalities in patients on peritoneal dialysis.

Authors:  Constantijn J A M Konings; Jeroen P Kooman; Marc Schonck; Ruben Dammers; Emiel Cheriex; Andrea P Palmans Meulemans; Arnold P G Hoeks; Bernardus van Kreel; Ulrich Gladziwa; Frank M van der Sande; Karel M L Leunissen
Journal:  Perit Dial Int       Date:  2002 Jul-Aug       Impact factor: 1.756

9.  Impact of hypertension on cardiomyopathy, morbidity and mortality in end-stage renal disease.

Authors:  R N Foley; P S Parfrey; J D Harnett; G M Kent; D C Murray; P E Barre
Journal:  Kidney Int       Date:  1996-05       Impact factor: 10.612

10.  Uncontrolled hypertension due to volume overload contributes to higher left ventricular mass index in CAPD patients.

Authors:  Mehmet Koc; Ahmet Toprak; Hakan Tezcan; Azra Bihorac; Emel Akoglu; Ishak Cetin Ozener
Journal:  Nephrol Dial Transplant       Date:  2002-09       Impact factor: 5.992

View more
  3 in total

1.  Association of body mass index and uncontrolled blood pressure with cardiovascular mortality in peritoneal dialysis patients.

Authors:  Wei Li; Ricong Xu; Yating Wang; Jiani Shen; Zhijian Li; Xueqing Yu; Haiping Mao
Journal:  J Hum Hypertens       Date:  2018-09-12       Impact factor: 3.012

Review 2.  Assessment and Management of Hypertension among Patients on Peritoneal Dialysis.

Authors:  Vasilios Vaios; Panagiotis I Georgianos; Vassilios Liakopoulos; Rajiv Agarwal
Journal:  Clin J Am Soc Nephrol       Date:  2018-10-19       Impact factor: 8.237

Review 3.  Comparison Between Automated Office Blood Pressure Measurements and Manual Office Blood Pressure Measurements-Implications in Individual Patients: a Systematic Review and Meta-analysis.

Authors:  Yacong Bo; Kin-On Kwok; Kareen Ka-Yin Chu; Eppie Yu-Han Leung; Chun Pong Yu; Samuel Yeung-Shan Wong; Eric Kam-Pui Lee
Journal:  Curr Hypertens Rep       Date:  2021-01-15       Impact factor: 5.369

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.