Intraocular lens delivery characteristics of the preloaded AcrySof IQ SN60WS/AcrySert injectable lens system.

Hon Shing Ong1, Malavika Subash, Amanjeet Sandhu, Mark R Wilkins.   

Abstract

OBJECTIVE: To evaluate the delivery characteristics of the AcrySof IQ SN60WS intraocular lens (IOL) injected via a preloaded AcrySert delivery system.
DESIGN: Prospective observational case series.
METHODS: setting: This study was carried out in the cataract service of an ophthalmic hospital that serves a large sector of inner-city London. patient population: The study included all patients undergoing routine phacoemulsification procedures with implantation of the SN60WS IOL via the preloaded system over 5 consecutive months. A total of 85 patients (85 eyes) were included in this study. intervention: Phacoemulsification procedures conducted by 7 surgeons were digitally captured. outcome measures: Video recordings of the IOL delivery stage were analyzed by a single observer. Of particular interests were the orientation of the leading haptic and optic on insertion, the degree of intrawound manipulation of the injector, and the time required to satisfactorily deliver the IOL into the capsular bag in a correct orientation. Problems of IOL delivery were also noted.
RESULTS: In 38 out of 85 eyes (45%), correct IOL delivery behavior was achieved with the leading haptic orientating to the left of the surgeon and thus did not require any intrawound rotational manipulation of the injector. Forty-seven of the 85 eyes (55%) required additional rotational manipulation of IOL orientation. Other problems recorded were trapped trailing haptic, haptic-optic adhesion, overriding of the plunger over the optic, and trauma to optic edge. The average time to achieve satisfactory IOL position was 47 seconds. IOL power and the grade of the operating surgeon did not appear to influence the event of a misdirected leading haptic.
CONCLUSIONS: The AcrySof SN60WS/AcrySert system does not appear to meet the expectations of pro-viding a predictable means of IOL delivery.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23541394     DOI: 10.1016/j.ajo.2013.01.032

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  10 in total

1.  Preloaded and non-preloaded intraocular lens delivery system and characteristics: human and porcine eyes trial.

Authors:  Byunghoon Chung; Hun Lee; Moonjung Choi; Kyoung Yul Seo; Eung Kweon Kim; Tae-Im Kim
Journal:  Int J Ophthalmol       Date:  2018-01-18       Impact factor: 1.779

2.  In vivo and in vitro results of an automated preloaded delivery system for IOL implantation in cataract surgery.

Authors:  Leonardo Mastropasqua; Lisa Toto; Erminia D'Ugo; Manuela Lanzini; Peter A Mattei; Gennaro Falconio; Emanuele Doronzo; Francesca Diomede; Oriana Trubiani
Journal:  Int Ophthalmol       Date:  2019-08-26       Impact factor: 2.031

3.  Preloaded injectable intraocular lenses: The way forward.

Authors:  Sanjay Chaudhary
Journal:  Indian J Ophthalmol       Date:  2018-03       Impact factor: 1.848

4.  Evaluation of semi-preloaded intraocular lens delivery system.

Authors:  Rajesh Rajesh
Journal:  Rom J Ophthalmol       Date:  2019 Jan-Mar

5.  Clinical Evaluation of a Novel Preloaded Intraocular Lens Delivery System During Routine Cataract Surgery.

Authors:  Daniel Black; Dean Corbett; Timothy V Roberts; Brendan Cronin; Pamela J Smith; D Priya Janakiraman; Beth E Jackson
Journal:  Clin Ophthalmol       Date:  2020-08-12

6.  Experimental Study on Delivery Performance of an Automated Preloaded Intraocular Lens Injector System for Corneal and Sclerocorneal Incisions.

Authors:  Tetsuro Oshika; Noriyuki Sasaki
Journal:  J Ophthalmol       Date:  2021-03-31       Impact factor: 1.909

7.  Long-Term Clinically Significant Posterior Capsular Opacification Development Pattern in Eyes Implanted with an Aspheric Monofocal Intraocular Lens with a Square Optic Edge.

Authors:  Javier Placeres Dabán; Juan Carlos Elvira; César Azrak; Lucía Rial; David P Piñero; José I Belda
Journal:  J Ophthalmol       Date:  2021-09-30       Impact factor: 1.909

Review 8.  Refractive Outcomes after Cataract Surgery.

Authors:  Ramin Khoramnia; Gerd Auffarth; Grzegorz Łabuz; George Pettit; Rajaraman Suryakumar
Journal:  Diagnostics (Basel)       Date:  2022-01-19

9.  Evaluation of Preloaded IOL Delivery System and Hydrophobic Acrylic Intraocular Lens in Cataract Surgery.

Authors:  Banu Acar; Isil M Torun; Suphi Acar
Journal:  Open Ophthalmol J       Date:  2018-06-14

10.  Comparison of a new IOL injector system against 3 standard IOL injector systems with different incision sizes: Miyake-Apple view experimental laboratory study.

Authors:  Lu Zhang; Sonja Schickhardt; Hui Fang; Florian Auerbach; Perfecto Cagampang; Patrick R Merz; Gerd U Auffarth
Journal:  J Cataract Refract Surg       Date:  2022-02-01       Impact factor: 3.351

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.