Literature DB >> 23528151

Computerized ellipse method for measuring acetabular version after total hip replacement--a precision study using synthetic and real radiographs.

Chen-Kun Liaw1, Tai-Yin Wu, Sheng-Mou Hou, Rong-Sen Yang, Kao-Shang Shih, Chiou-Shann Fuh.   

Abstract

BACKGROUND: Previous work by our group to address the problem of acetabular positioning based on 2D methods resulted in the development of a measurement method with better precision--Liaw's version. This method may help the early diagnosis of acetabular loosening. In the present study, we hypothesized that our computerized ellipse method could improve the precision of measuring acetabular version.
METHODS: We developed our Elliversion software to measure acetabular version. Using total hip replacement (THR) Simulator, 96 radiographs were synthesized with random femoral inclination and 5° to 52° version, half with the femoral head included and half without. These synthetic radiographs and 28 real radiographs were measured with both Elliversion and the trigonometric method twice by one of the authors with a one-week interval between measurements. We then calculated the difference in the repeated measurements. Student's t-test was used for statistical analysis of the measuring error and inter-measurement difference.
RESULTS: In the precision study, for synthetic radiographs including the femoral head, the ellipse method was significantly better than the trigonometric method (p < 0.01). For synthetic radiographs without the femoral head, there was no significant difference between the ellipse method and the trigonometric method (p = 0.19). As for the repeated measurements, for synthetic radiographs including the femoral head, the ellipse method was significantly better than the trigonometric method (p = 0.001), whereas for synthetic radiographs without the femoral head, there was no significant difference between the two methods (p = 0.17). For real radiographs, there was no significant difference between the two measuring methods (p = 0.12). However, if we excluded the four poor-quality radiographs, there was a significant difference between the two measuring methods (p = 0.04). DISCUSSION: We developed a computerized ellipse method for measuring acetabular version on synthetic radiographs and good-quality real radiographs. This method is characterized by its superior precision as compared to the trigonometric method. With the 2D standardized method (Liaw's version), improving the precision of measurement will help earlier diagnosis of acetabular loosening.

Entities:  

Mesh:

Year:  2013        PMID: 23528151     DOI: 10.3109/10929088.2013.779749

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  4 in total

Review 1.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

2.  A Novel Method for Correcting Pelvic Tilt on Anteroposterior Pelvic Radiographs.

Authors:  Jeffrey M Muir; John Vincent; Joseph Schipper; Varsha D Gobin; Meinusha Govindarajan; Karlina Fiaes; Jonathan Vigdorchik
Journal:  Cureus       Date:  2019-12-02

3.  Ellipse method for measuring Liaw's anteversion of the acetabular component after total hip arthroplasty.

Authors:  Kuei-Lin Yeh; Tai-Yin Wu; Hsuan-Hsiao Ma; Sheng-Mou Hou; Chen-Kun Liaw
Journal:  BMC Musculoskelet Disord       Date:  2020-10-08       Impact factor: 2.362

4.  Stress shielding effects of two prosthetic groups after total hip joint simulation replacement.

Authors:  Chengdong Piao; Dankai Wu; Min Luo; Hongshun Ma
Journal:  J Orthop Surg Res       Date:  2014-08-30       Impact factor: 2.359

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.