Literature DB >> 23526478

Chemical Exchange Saturation Transfer is Unaffected by Modest Changes in Pressure.

Benjamin C Webber1, Christiane E Carney, Mark Woods.   

Abstract

ParaCEST (paramagnetic Chemical Exchange Saturation Transfer) agents offer an unparalleled opportunity to perform quantitative molecular imaging by MRI. Agents that can alter the image contrast they generate in response to changes in local environmental parameters such as pH, glucose concentration or lactate concentration can be used ratiometrically to quantitatively describe the local tissue environment. However, when performing such quantitative measurements it is important that the results are not confounded by changes in a second environmental parameter. In vivo pressure varies quite considerably, both through the respiratory cycle and from tissue to tissue (tumors in particular have high interstitial pressures). Since paraCEST agents have positive activation volumes, their exchange kinetics and therefore the CEST effect that they generate are necessarily related to pressure. The purpose of this investigation was to examine whether the relatively small changes in pressure exhibited in vivo could affect CEST sufficiently to confound attempts to quantify other local environmental parameters. The CEST properties of a rigid EuDOTA-tetraamide was examined at temperatures ranging from 288 to 319 K, at applied pressures ranging from 0 to 414 kPa and pre-saturation (B1) powers ranging from 524 to 935 Hz. At no point was pressure found to affect the CEST generated by this chelate, indicating that changes in in vivo pressure is unlikely to confound the quantitative measurement of physiologically relevant parameters by paraCEST MRI.

Entities:  

Keywords:  Europium chelates; MRI contrast agents; Macrocyclic ligands; Variable pressure; paraCEST

Year:  2012        PMID: 23526478      PMCID: PMC3604895          DOI: 10.1002/ejic.201101291

Source DB:  PubMed          Journal:  Eur J Inorg Chem        ISSN: 1434-1948            Impact factor:   2.524


  24 in total

1.  A paramagnetic MRI-CEST agent responsive to lactate concentration.

Authors:  Silvio Aime; Daniela Delli Castelli; Franco Fedeli; Enzo Terreno
Journal:  J Am Chem Soc       Date:  2002-08-14       Impact factor: 15.419

2.  Controlling the variation of axial water exchange rates in macrocyclic lanthanide(III) complexes.

Authors:  Silvio Aime; Alessandro Barge; Andrei S Batsanov; Mauro Botta; Daniela Delli Castelli; Franco Fedeli; Armando Mortillaro; David Parker; Horst Puschmann
Journal:  Chem Commun (Camb)       Date:  2002-05-21       Impact factor: 6.222

3.  Selective sensing of zinc ions with a PARACEST contrast agent.

Authors:  Robert Trokowski; Jimin Ren; Ferenc Krisztián Kálmán; A Dean Sherry
Journal:  Angew Chem Int Ed Engl       Date:  2005-10-28       Impact factor: 15.336

4.  Numerical solution of the Bloch equations provides insights into the optimum design of PARACEST agents for MRI.

Authors:  Donald E Woessner; Shanrong Zhang; Matthew E Merritt; A Dean Sherry
Journal:  Magn Reson Med       Date:  2005-04       Impact factor: 4.668

Review 5.  Chemical exchange saturation transfer contrast agents for magnetic resonance imaging.

Authors:  A Dean Sherry; Mark Woods
Journal:  Annu Rev Biomed Eng       Date:  2008       Impact factor: 9.590

6.  Europium(III) macrocyclic complexes with alcohol pendant groups as chemical exchange saturation transfer agents.

Authors:  Mark Woods; Donald E Woessner; Piyu Zhao; Azhar Pasha; Meng-Yin Yang; Ching-Hui Huang; Olga Vasalitiy; Janet R Morrow; A Dean Sherry
Journal:  J Am Chem Soc       Date:  2006-08-09       Impact factor: 15.419

7.  Investigations into whole water, prototropic and amide proton exchange in lanthanide(III) DOTA-tetraamide chelates.

Authors:  Mark Woods; Azhar Pasha; Piyu Zhao; Gyula Tircso; Somdatta Chowdhury; Garry Kiefer; Donald E Woessner; A Dean Sherry
Journal:  Dalton Trans       Date:  2011-05-31       Impact factor: 4.390

8.  High resolution pH(e) imaging of rat glioma using pH-dependent relaxivity.

Authors:  Maria L Garcia-Martin; Gary V Martinez; Natarajan Raghunand; A Dean Sherry; Shanrong Zhang; Robert J Gillies
Journal:  Magn Reson Med       Date:  2006-02       Impact factor: 4.668

9.  Using two chemical exchange saturation transfer magnetic resonance imaging contrast agents for molecular imaging studies.

Authors:  M Meser Ali; Guanshu Liu; Tejas Shah; Chris A Flask; Mark D Pagel
Journal:  Acc Chem Res       Date:  2009-07-21       Impact factor: 22.384

10.  Cyclen-based phenylboronate ligands and their Eu3+ complexes for sensing glucose by MRI.

Authors:  Robert Trokowski; Shanrong Zhang; A Dean Sherry
Journal:  Bioconjug Chem       Date:  2004 Nov-Dec       Impact factor: 4.774

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.