Literature DB >> 23525945

Diagnosis and treatment planning of acute aortic emergencies using a handheld DICOM viewer.

Asim F Choudhri1, Patrick T Norton, Thomas M Carr, James R Stone, Klaus D Hagspiel, Michael D Dake.   

Abstract

Acute aortic syndromes and traumatic aortic injury are often diagnosed on CT angiography, possibly requiring emergent intervention. Advances in handheld computing have created the possibility of viewing full DICOM datasets from a remote location. We evaluated the ability to diagnose and characterize acute aortic pathologies on CT angiograms of the thorax using an iPhone-based DICOM viewer. This study was performed after Institutional Review Board approval. Fifteen CT angiograms of the thorax in suspected acute aortic syndromes were evaluated by three blinded radiologists on a handheld device using a DICOM viewer. Studies were evaluated for the ability to identify and classify aortic dissection, transection, or intramural hematoma, measure aortic dimensions, and identify mediastinal hematoma, arch variants, and pulmonary pathology. Studies were compared to blinded interpretations on a dedicated PACS workstation. The aortic pathology was correctly identified as aortic transection/pseudoaneurysm (n = 5), type A dissection (n = 2), and type A intramural hematoma (n = 1) by all reviewers, with no false-positive interpretations. This represents a sensitivity and specificity of 100 %. Mediastinal hematoma (n = 6), pneumothorax (five right, three left), and arch vessel involvement (n = 2) were identified in all cases. There was 88.5 % accuracy in identifying arch variants. Measurement of the size of the involved aortic segment was similar on handheld device and PACS workstation; however the adjacent normal aorta was 1.2 ± 1.0 mm larger on the handheld device (p = 0.03). Handheld DICOM viewers may be useful for emergent consultations and triage, and may expedite preprocedure planning to reduce the time interval between diagnostic scan and therapeutic intervention.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23525945     DOI: 10.1007/s10140-013-1118-8

Source DB:  PubMed          Journal:  Emerg Radiol        ISSN: 1070-3004


  19 in total

1.  Endovascular stent-graft placement for the treatment of acute aortic dissection.

Authors:  M D Dake; N Kato; R S Mitchell; C P Semba; M K Razavi; T Shimono; T Hirano; K Takeda; I Yada; D C Miller
Journal:  N Engl J Med       Date:  1999-05-20       Impact factor: 91.245

2.  Flexible image evaluation: iPad versus secondary-class monitors for review of MR spinal emergency cases, a comparative study.

Authors:  Jonathan P McNulty; John T Ryan; Michael G Evanoff; Louise A Rainford
Journal:  Acad Radiol       Date:  2012-04-14       Impact factor: 3.173

3.  Initial experience with a handheld device digital imaging and communications in medicine viewer: OsiriX mobile on the iPhone.

Authors:  Asim F Choudhri; Martin G Radvany
Journal:  J Digit Imaging       Date:  2011-04       Impact factor: 4.056

Review 4.  Blunt aortic injury.

Authors:  David G Neschis; Thomas M Scalea; William R Flinn; Bartley P Griffith
Journal:  N Engl J Med       Date:  2008-10-16       Impact factor: 91.245

5.  Making the transition: the role of helical CT in the evaluation of potentially acute thoracic aortic injuries.

Authors:  M S Parker; T L Matheson; A V Rao; C D Sherbourne; K G Jordan; M J Landay; G L Miller; J A Summa
Journal:  AJR Am J Roentgenol       Date:  2001-05       Impact factor: 3.959

6.  Suspected aortic dissection and other aortic disorders: multi-detector row CT in 373 cases in the emergency setting.

Authors:  Robert G Hayter; James T Rhea; Andrew Small; Faranak S Tafazoli; Robert A Novelline
Journal:  Radiology       Date:  2006-02-01       Impact factor: 11.105

Review 7.  Pictorial review: computed tomography features of cardiovascular emergencies and associated imminent decompensation.

Authors:  Tow Non Yeow; Vikram Muppalla Raju; Nanda Venkatanarasimha; Bruce M Fox; Carl A Roobottom
Journal:  Emerg Radiol       Date:  2010-10-07

8.  Endovascular stenting for traumatic aortic injury: an emerging new standard of care.

Authors:  Sina L Moainie; David G Neschis; James S Gammie; James M Brown; Robert S Poston; Thomas M Scalea; Bartley P Griffith
Journal:  Ann Thorac Surg       Date:  2008-05       Impact factor: 4.330

Review 9.  Acute traumatic aortic injury: imaging evaluation and management.

Authors:  Scott D Steenburg; James G Ravenel; John S Ikonomidis; Claudio Schönholz; Scott Reeves
Journal:  Radiology       Date:  2008-09       Impact factor: 11.105

Review 10.  Emergency stent grafting of type B aortic dissection: technical considerations.

Authors:  Tommaso Lupattelli; Francesco Giuseppe Garaci; Antonio Basile; Andrea Casini; Ilias Dalainas; Daniela Paola Minnella; Roberto Iezzi
Journal:  Emerg Radiol       Date:  2008-08-28
View more
  6 in total

1.  Limitations in and Solutions for Improving the Functionality of Picture Archiving and Communication System: an Exploratory Study of PACS Professionals' Perspectives.

Authors:  Mona Alhajeri; Syed Ghulam Sarwar Shah
Journal:  J Digit Imaging       Date:  2019-02       Impact factor: 4.056

2.  Remote reading of coronary CTA exams using a tablet computer: utility for stenosis assessment and identification of coronary anomalies.

Authors:  Stefan L Zimmerman; Cheng T Lin; Linda C Chu; John Eng; Elliot K Fishman
Journal:  Emerg Radiol       Date:  2016-04-16

3.  A Feasibility Study of Real-Time Remote CT Reading for Suspected Acute Appendicitis Using an iPhone.

Authors:  Changsun Kim; Bossng Kang; Hyuk Joong Choi; Joon Bum Park
Journal:  J Digit Imaging       Date:  2015-08       Impact factor: 4.056

4.  Evaluation of Coronary Artery Disease and Coronary Anomalies with a Handheld Smartphone.

Authors:  Cheng Ting Lin; Stefan Loy Zimmerman; Linda C Chu; John Eng; Elliot K Fishman
Journal:  J Digit Imaging       Date:  2017-12       Impact factor: 4.056

5.  A low threshold to ECG-gated repeat CTA reduces the risk of false-positive diagnosis of type A dissection in interhospital referrals: a case series study.

Authors:  Angela Kornberger; Iris Burck; Hazem El Beyrouti; Nancy Halloum; Andres Beiras-Fernandez; Christian-Friedrich Vahl
Journal:  Ther Clin Risk Manag       Date:  2018-10-17       Impact factor: 2.423

6.  Service-oriented Device Connectivity interface for a situation recognition system in the OR.

Authors:  Denise Junger; Patrick Beyersdorffer; Christian Kücherer; Oliver Burgert
Journal:  Int J Comput Assist Radiol Surg       Date:  2022-05-20       Impact factor: 3.421

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.