Literature DB >> 23523448

Multiple overlapping bare stents for endovascular visceral aneurysm repair: a potential alternative endovascular strategy to multilayer stents.

Lei Zhang1, Cun-ping Yin, Hai-yan Li, Jun-min Bao, Zhi-qing Zhao, Le-feng Qu, Xiang Feng, Rui Feng, Qing-sheng Lu, Zai-ping Jing.   

Abstract

BACKGROUND: Multilayer stent has become a new endovascular strategy for visceral artery aneurysm repair. However, its use was not allowed in some areas, such as China. This study evaluates an alternative method: multiple overlapping bare stents for repairing visceral artery aneurysms.
METHODS: Twenty-four patients with celiac artery aneurysm (n = 2), splenic artery aneurysm (n = 8), hepatic artery aneurysm (n = 3), superior mesenteric artery aneurysm (n = 6), and renal artery aneurysm (n = 5) were treated with 2 to 4 overlapping bare stents. Long-term results, including clinical achievement ratio and target artery patency, were followed up with computed tomographic angiography.
RESULTS: Insertion of overlapping bare stents was successful in all patients. Five aneurysms (21%) were totally excluded 3 months after operation, increasing to 12 (50%) and 20 (83%) aneurysms with total isolation at 6 and 12 months' follow-up, respectively. The clinical achievement ratios of multiple overlapping bare stents on splenic artery aneurysms, hepatic artery aneurysms, renal artery aneurysms, celiac artery aneurysms, and superior mesenteric artery aneurysms were 75%, 100%, 80%, 50%, and 100%, respectively. All cases combined had 100% target artery patency.
CONCLUSIONS: Preliminary experience showed that repair using multiple overlapping bare stents seemed to be a potential alternative strategy for treating visceral artery aneurysm, resulting in target artery patency. However, the exact mechanism requires further study and more cases should be involved.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23523448     DOI: 10.1016/j.avsg.2012.07.013

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  3 in total

1.  Comprehensive assessment of mechanical behavior of an extremely long stent graft to control hemorrhage in torso.

Authors:  Moataz Elsisy; Bryan W Tillman; Catherine Go; Jenna Kuhn; Sung K Cho; William W Clark; Junkyu Park; Youngjae Chun
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2020-01-14       Impact factor: 3.368

2.  Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm.

Authors:  Siang Lin Yeow; Hwa Liang Leo
Journal:  Comput Math Methods Med       Date:  2016-05-09       Impact factor: 2.238

3.  Endovascular Double-Layer Bare Stent Placement in the Treatment of Posttraumatic Pseudoaneurysm.

Authors:  Wenle Tan; Shubin Dou; Jijin Yang; Jiang Xiong; Xiquan Zhang; Feng Duan
Journal:  Biomed Res Int       Date:  2021-03-11       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.