4π noncoplanar stereotactic body radiation therapy for centrally located or larger lung tumors.

Peng Dong1, Percy Lee, Dan Ruan, Troy Long, Edwin Romeijn, Daniel A Low, Patrick Kupelian, John Abraham, Yingli Yang, Ke Sheng.   

Abstract

PURPOSE: To investigate the dosimetric improvements in stereotactic body radiation therapy for patients with larger or central lung tumors using a highly noncoplanar 4π planning system. METHODS AND MATERIALS: This study involved 12 patients with centrally located or larger lung tumors previously treated with 7- to 9-field static beam intensity modulated radiation therapy to 50 Gy. They were replanned using volumetric modulated arc therapy and 4π plans, in which a column generation method was used to optimize the beam orientation and the fluence map. Maximum doses to the heart, esophagus, trachea/bronchus, and spinal cord, as well as the 50% isodose volume, the lung volumes receiving 20, 10, and 5 Gy were minimized and compared against the clinical plans. A dose escalation study was performed to determine whether a higher prescription dose to the tumor would be achievable using 4π without violating dose limits set by the clinical plans. The deliverability of 4π plans was preliminarily tested.
RESULTS: Using 4π plans, the maximum heart, esophagus, trachea, bronchus and spinal cord doses were reduced by 32%, 72%, 37%, 44%, and 53% (P≤.001), respectively, and R50 was reduced by more than 50%. Lung V20, V10, and V5 were reduced by 64%, 53%, and 32% (P≤.001), respectively. The improved sparing of organs at risk was achieved while also improving planning target volume (PTV) coverage. The minimal PTV doses were increased by the 4π plans by 12% (P=.002). Consequently, escalated PTV doses of 68 to 70 Gy were achieved in all patients.
CONCLUSIONS: We have shown that there is a large potential for plan quality improvement and dose escalation for patients with larger or centrally located lung tumors using noncoplanar beams with sufficient quality and quantity. Compared against the clinical volumetric modulated arc therapy and static intensity modulated radiation therapy plans, the 4π plans yielded significantly and consistently improved tumor coverage and critical organ sparing. Given the known challenges in central structure dose constraints in stereotactic body radiation therapy to the lung, 4π planning may increase efficacy and reduce toxicity.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23523322     DOI: 10.1016/j.ijrobp.2013.02.002

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  56 in total

1.  A novel software and conceptual design of the hardware platform for intensity modulated radiation therapy.

Authors:  Dan Nguyen; Dan Ruan; Daniel O'Connor; Kaley Woods; Daniel A Low; Salime Boucher; Ke Sheng
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  VMAT optimization with dynamic collimator rotation.

Authors:  Qihui Lyu; Daniel O'Connor; Dan Ruan; Victoria Yu; Dan Nguyen; Ke Sheng
Journal:  Med Phys       Date:  2018-05-03       Impact factor: 4.071

3.  Many-isocenter optimization for robotic radiotherapy.

Authors:  Qihui Lyu; Ryan Neph; Victoria Y Yu; Dan Ruan; Salime Boucher; Ke Sheng
Journal:  Phys Med Biol       Date:  2020-02-10       Impact factor: 3.609

4.  Analytical modeling and feasibility study of a multi-GPU cloud-based server (MGCS) framework for non-voxel-based dose calculations.

Authors:  J Neylon; Y Min; P Kupelian; D A Low; A Santhanam
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-08-25       Impact factor: 2.924

5.  Nonisocentric treatment strategy for breast radiation therapy: a proof of concept study.

Authors:  Ruijiang Li; Lei Xing; Kathleen C Horst; Karl Bush
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-03-15       Impact factor: 7.038

6.  4π plan optimization for cortical-sparing brain radiotherapy.

Authors:  Vyacheslav L Murzin; Kaley Woods; Vitali Moiseenko; Roshan Karunamuni; Kathryn R Tringale; Tyler M Seibert; Michael J Connor; Daniel R Simpson; Ke Sheng; Jona A Hattangadi-Gluth
Journal:  Radiother Oncol       Date:  2018-03-05       Impact factor: 6.280

7.  Inverse 4D conformal planning for lung SBRT using particle swarm optimization.

Authors:  A Modiri; X Gu; A Hagan; R Bland; P Iyengar; R Timmerman; A Sawant
Journal:  Phys Med Biol       Date:  2016-08-01       Impact factor: 3.609

8.  Cleaning the dose falloff in lung SBRT plan.

Authors:  Dharmin Desai; Ganesh Narayanasamy; Milan Bimali; Ivan Cordrey; Hisham Elasmar; Senthamizhchelvan Srinivasan; Ellis Lee Johnson
Journal:  J Appl Clin Med Phys       Date:  2020-12-07       Impact factor: 2.102

9.  Deterministic direct aperture optimization using multiphase piecewise constant segmentation.

Authors:  Dan Nguyen; Daniel O'Connor; Dan Ruan; Ke Sheng
Journal:  Med Phys       Date:  2017-09-22       Impact factor: 4.071

10.  Automated intensity modulated treatment planning: The expedited constrained hierarchical optimization (ECHO) system.

Authors:  Masoud Zarepisheh; Linda Hong; Ying Zhou; Jung Hun Oh; James G Mechalakos; Margie A Hunt; Gig S Mageras; Joseph O Deasy
Journal:  Med Phys       Date:  2019-05-29       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.