Literature DB >> 23522583

Histomorphological and immunofluorescence evaluation of clear corneal incisions after microcoaxial phacoemulsification with 2.2 mm and 1.8 mm systems.

Abhay R Vasavada1, Kaid Johar, Mamidipudi R Praveen, Viraj A Vasavada, Anshul I Arora.   

Abstract

PURPOSE: To compare changes in the incision's histomorphology and denaturation of collagen I in rabbit eyes having microcoaxial phacoemulsification through 2.2 mm and 1.8 mm incision-compatible systems.
DESIGN: Randomized experimental trial.
SETTING: Iladevi Cataract & IOL Research Centre, Ahmedabad, India.
METHODS: Thirty rabbit eyes were randomized into Group 1 (microcoaxial phacoemulsification through 2.2 mm incisions using Infiniti system [torsional ultrasound]) and Group 2 (microcoaxial phacoemulsification through 1.8 mm incisions using Stellaris system [longitudinal ultrasound]). Each group was then divided into 3 subgroups of 5 eyes each based on 1 of the 3 intervention options: phacoemulsification only, intraocular lens (IOL) insertion only, and phacoemulsification with IOL insertion. Left eyes were randomized for microcoaxial phacoemulsification, and right eyes were treated as controls.
RESULTS: After phacoemulsification, eyes in Group 1 showed loss of epithelium at the roof of the incisions and Descemet membrane detachment at the floor of the incisions. These findings did not change after IOL insertion. After phacoemulsification, eyes in Group 2 showed loss of epithelium, but Descemet membrane remained attached. There was a longitudinal split in the incision's stroma in the direction of internal entry. The stromal damage increased after IOL implantation. Immunofluorescence studies showed no obvious irregularities in the arrangement of collagen I in either group. A dot blot analysis showed significant denaturation of collagen I in Group 2.
CONCLUSION: The histomorphology of the 2.2 mm system incision showed localized Descemet membrane detachment and endothelial cell loss. The 1.8 mm system incision showed exaggerated stromal damage after IOL insertion.
Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23522583     DOI: 10.1016/j.jcrs.2012.12.035

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  2 in total

Review 1.  Different-sized incisions for phacoemulsification in age-related cataract.

Authors:  Chongfei Jin; Xinyi Chen; Andrew Law; Yunhee Kang; Xue Wang; Wen Xu; Ke Yao
Journal:  Cochrane Database Syst Rev       Date:  2017-09-20

2.  Incidence of Incision-Related Descemet Membrane Detachment Using Phacoemulsification With Trapezoid vs Conventional 2.2-mm Clear Corneal Incision: A Randomized Clinical Trial.

Authors:  Ye Dai; Zhenzhen Liu; Wei Wang; Xiaotong Han; Ling Jin; Xiaoyun Chen; Guangming Jin; Lanhua Wang; Enen Zhang; Bo Qu; Jianping Liu; Nathan Congdon; Mingguang He; Lixia Luo; Yizhi Liu
Journal:  JAMA Ophthalmol       Date:  2021-11-01       Impact factor: 8.253

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.