Literature DB >> 23520409

Rapidly swept, ultra-widely-tunable 1060 nm MEMS-VCSELs.

V Jayaraman1, G D Cole, M Robertson, C Burgner, D John, A Uddin, A Cable.   

Abstract

Demonstrated are 1060 nm microelectromechanical-systems-based tunable vertical-cavity surface-emitting lasers (MEMS-VCSELs) with a 100 nm continuous tuning range under repetitively scanned operation at rates beyond 500 kHz and a 90 nm continuous tuning range under static operation. These devices employ a thin strained InGaAs multiple quantum well active region integrated with a fully oxidised GaAs/AlxOy bottom mirror and a suspended dielectric top mirror. The devices are optically pumped via 850 nm light. These ultra-widely tunable lasers represent the first MEMS-VCSELs reported in this wavelength range, and are ideally suited for application in ophthalmic swept-source optical coherence tomography.

Entities:  

Year:  2012        PMID: 23520409      PMCID: PMC3601947          DOI: 10.1049/el.2012.3180

Source DB:  PubMed          Journal:  Electron Lett        ISSN: 0013-5194            Impact factor:   1.314


  6 in total

1.  Tunable single-mode fiber-VCSEL using an intracavity polymer microlens.

Authors:  Nicolas Laurand; Benoit Guilhabert; Erdan Gu; Stephane Calvez; Martin D Dawson
Journal:  Opt Lett       Date:  2007-10-01       Impact factor: 3.776

2.  High-sweep-rate 1310 nm MEMS-VCSEL with 150 nm continuous tuning range.

Authors:  V Jayaraman; G D Cole; M Robertson; A Uddin; A Cable
Journal:  Electron Lett       Date:  2012-07-05       Impact factor: 1.314

3.  High speed engine gas thermometry by Fourier-domain mode-locked laser absorption spectroscopy.

Authors:  Laura A Kranendonk; Xinliang An; Andrew W Caswell; Randy E Herold; Scott T Sanders; Robert Huber; James G Fujimoto; Yasuhiro Okura; Yasuhiro Urata
Journal:  Opt Express       Date:  2007-11-12       Impact factor: 3.894

4.  Short-wavelength MEMS-tunable VCSELs.

Authors:  Garrett D Cole; Elaine Behymer; Tiziana C Bond; Lynford L Goddard
Journal:  Opt Express       Date:  2008-09-29       Impact factor: 3.894

5.  Surface micromachined tunable 1.55 μm-VCSEL with 102 nm continuous single-mode tuning.

Authors:  C Gierl; T Gruendl; P Debernardi; K Zogal; C Grasse; H A Davani; G Böhm; S Jatta; F Küppers; P Meissner; M-C Amann
Journal:  Opt Express       Date:  2011-08-29       Impact factor: 3.894

6.  Ultrahigh speed 1050nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second.

Authors:  Benjamin Potsaid; Bernhard Baumann; David Huang; Scott Barry; Alex E Cable; Joel S Schuman; Jay S Duker; James G Fujimoto
Journal:  Opt Express       Date:  2010-09-13       Impact factor: 3.894

  6 in total
  9 in total

1.  Photonic integrated Mach-Zehnder interferometer with an on-chip reference arm for optical coherence tomography.

Authors:  Günay Yurtsever; Boris Považay; Aneesh Alex; Behrooz Zabihian; Wolfgang Drexler; Roel Baets
Journal:  Biomed Opt Express       Date:  2014-03-03       Impact factor: 3.732

2.  16  MHz wavelength-swept and wavelength-stepped laser architectures based on stretched-pulse active mode locking with a single continuously chirped fiber Bragg grating.

Authors:  Reza Khazaeinezhad; Meena Siddiqui; Benjamin J Vakoc
Journal:  Opt Lett       Date:  2017-05-15       Impact factor: 3.776

3.  Quantitative upper airway endoscopy with swept-source anatomical optical coherence tomography.

Authors:  Kushal Wijesundara; Carlton Zdanski; Julia Kimbell; Hillel Price; Nicusor Iftimia; Amy L Oldenburg
Journal:  Biomed Opt Express       Date:  2014-02-19       Impact factor: 3.732

Review 4.  Fourier Domain Mode Locked Laser and Its Applications.

Authors:  Dongmei Huang; Yihuan Shi; Feng Li; P K A Wai
Journal:  Sensors (Basel)       Date:  2022-04-20       Impact factor: 3.847

5.  Phase-sensitive swept-source optical coherence tomography imaging of the human retina with a vertical cavity surface-emitting laser light source.

Authors:  WooJhon Choi; Benjamin Potsaid; Vijaysekhar Jayaraman; Bernhard Baumann; Ireneusz Grulkowski; Jonathan J Liu; Chen D Lu; Alex E Cable; David Huang; Jay S Duker; James G Fujimoto
Journal:  Opt Lett       Date:  2013-02-01       Impact factor: 3.776

6.  Serial optical coherence scanner for large-scale brain imaging at microscopic resolution.

Authors:  Hui Wang; Junfeng Zhu; Taner Akkin
Journal:  Neuroimage       Date:  2013-10-04       Impact factor: 6.556

7.  High-precision, high-accuracy ultralong-range swept-source optical coherence tomography using vertical cavity surface emitting laser light source.

Authors:  Ireneusz Grulkowski; Jonathan J Liu; Benjamin Potsaid; Vijaysekhar Jayaraman; James Jiang; James G Fujimoto; Alex E Cable
Journal:  Opt Lett       Date:  2013-03-01       Impact factor: 3.776

8.  Wideband Electrically-Pumped 1050 nm MEMS-Tunable VCSEL for Ophthalmic Imaging.

Authors:  Demis D John; Christopher B Burgner; Benjamin Potsaid; Martin E Robertson; Byung Kun Lee; Woo Jhon Choi; Alex E Cable; James G Fujimoto; Vijaysekhar Jayaraman
Journal:  J Lightwave Technol       Date:  2015-02-02       Impact factor: 4.142

9.  Melanin concentration and depolarization metrics measurement by polarization-sensitive optical coherence tomography.

Authors:  Masahiro Yamanari; Mutsuki Mase; Ryo Obata; Mitsuhiro Matsuzaki; Takahiro Minami; Seiji Takagi; Motoshi Yamamoto; Noriko Miyamoto; Koji Ueda; Naoshi Koide; Tadao Maeda; Kota Totani; Nobuyori Aoki; Yasuhiko Hirami; Satoshi Sugiyama; Michiko Mandai; Makoto Aihara; Masayo Takahashi; Satoshi Kato; Yasuo Kurimoto
Journal:  Sci Rep       Date:  2020-11-11       Impact factor: 4.379

  9 in total