Literature DB >> 23517809

Bladder-rectum spacer balloon in high-dose-rate brachytherapy in cervix carcinoma.

Bhavana Rai1, Firuza D Patel, Santam Chakraborty, Suresh C Sharma, Rakesh Kapoor, Abi Santhosh Aprem.   

Abstract

PURPOSE: To compare bladder and rectum doses with the use of a bladder-rectum spacer balloon (BRSB) versus standard gauze packing in the same patient receiving 2 high-dose-rate intracavitary brachytherapy fractions. METHODS AND MATERIALS: This was a randomized study to compare the reduction in bladder and rectum doses with the use of a BRSB compared with standard gauze packing in patients with carcinoma of the cervix being treated with high-dose-rate intracavitary brachytherapy. The patients were randomized between 2 arms. In arm A, vaginal packing was done with standard gauze packing in the first application, and BRSB was used in the second application. Arm B was the reverse of arm A. The International Commission for Radiation Units and Measurement (ICRU) point doses and doses to 0.1-cm(3), 1-cm(3), 2-cm(3), 5-cm(3), and 10-cm(3) volumes of bladder and rectum were compared. The patients were also subjectively assessed for the ease of application and the time taken for application. Statistical analysis was done using the paired t test.
RESULTS: A total of 43 patients were enrolled; however, 3 patients had to be excluded because the BRSB could not be inserted owing to unfavorable local anatomy. Thus 40 patients (80 plans) were evaluated. The application was difficult in 3 patients with BRSB, and in 2 patients with BRSB the application time was prolonged. There was no significant difference in bladder doses to 0.1 cm(3), 1 cm(3), 2 cm(3), 5 cm(3), and 10 cm(3) and ICRU bladder point. Statistically significant dose reductions to 0.1-cm(3), 1-cm(3), and 2-cm(3) volumes for rectum were observed with the BRSB. No significant differences in 5-cm(3) and 10-cm(3) volumes and ICRU rectum point were observed.
CONCLUSION: A statistically significant dose reduction was observed for small high-dose volumes in rectum with the BRSB. The doses to bladder were comparable for BRSB and gauze packing. Transparent balloons of variable sizes are recommended for patients with a less spacious vaginal cavity.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23517809     DOI: 10.1016/j.ijrobp.2012.09.037

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  8 in total

1.  Image-Guided High-Dose Rate Brachytherapy in Cervix Carcinoma Using Balloon Catheter and Belt Immobilization System.

Authors:  Qiyong Fan; Anamaria R Yeung; Robert Amdur; Richard Helmig; Justin Park; Jonathan Li; Darren Kahler; Chihray Liu; Bo Lu
Journal:  Technol Cancer Res Treat       Date:  2016-02-10

Review 2.  In vivo dosimetry: trends and prospects for brachytherapy.

Authors:  G Kertzscher; A Rosenfeld; S Beddar; K Tanderup; J E Cygler
Journal:  Br J Radiol       Date:  2014-07-08       Impact factor: 3.039

3.  Rectum Protection by Rectal Gel Injection in Cervical Cancer Brachytherapy: A Dosimetric Study via Deformable Surface Dose Accumulation and Machine-Learning-Based Discriminative Modeling.

Authors:  Xuetao Wang; Bailin Zhang; Qiang He; Yilin Kong; Zhenhui Dai; Haoyu Meng; Fangjun Huang; Shengfeng Zhang; Yuanhu Zhu; Xiang Tan; Xin Zhen
Journal:  Front Oncol       Date:  2021-04-16       Impact factor: 6.244

4.  A comparison of dosimetric parameters in high-dose-rate intracavitary brachytherapy using tandem and ring applicators: is the combination of a rectal retractor and radio-opaque vaginal packing better than rectal retractor alone for rectum sparing in cervical cancer?

Authors:  Siddharth Vats; Shabnum Thakur; Mukesh Sharma; Manish Gupta; Lalit Chandrakant; Muninder Negi; Swati Verma; Anup Negi; Vivek Kumar; Parul Sharma; Rattan Mahesh Negi
Journal:  Ecancermedicalscience       Date:  2022-08-08

5.  Reproducibility of vaginal immobilization balloons in situ overnight for cervical cancer brachytherapy.

Authors:  Uma D Goyal; Paras P Mehta; Susan Samreth; John Gloss; Haiyan Cui; Denise Roe; Shona Dougherty
Journal:  J Contemp Brachytherapy       Date:  2021-05-13

6.  Clinical analysis of speculum-based vaginal packing for high-dose-rate intracavitary tandem and ovoid brachytherapy in cervical cancer.

Authors:  Shivani Sud; Toni Roth; Ellen Jones
Journal:  J Contemp Brachytherapy       Date:  2018-02-28

7.  Initial experience using superflab as intravaginal packing during interstitial brachytherapy for advanced gynecologic cancer.

Authors:  Michael Kharouta; Martha Malin; Christina Son; Hania Al-Hallaq; Yasmin Hasan
Journal:  J Contemp Brachytherapy       Date:  2018-06-20

8.  Dosimetric comparison of two different applicators and rectal retraction methods used in inverse optimization-based intracavitary brachytherapy for cervical cancer.

Authors:  Fatih Biltekin; Melis Gultekin; Melek Tugce Yilmaz; Ferah Yildiz
Journal:  J Contemp Brachytherapy       Date:  2020-02-28
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.