Literature DB >> 23513247

Emergency department management of suspected carbon monoxide poisoning: role of pulse CO-oximetry.

Mustapha Sebbane1, Pierre-Géraud Claret, Grégoire Mercier, Sophie Lefebvre, Richard Théry, Richard Dumont, Michel Maillé, Jean-Paul Richard, Jean-Jacques Eledjam, Jean-Emmanuel de La Coussaye.   

Abstract

BACKGROUND: The RAD-57 pulse CO-oximeter is a lightweight device allowing noninvasive measurement of blood carboxyhemoglobin (S(pCO)). We assessed the diagnostic value of pulse CO-oximetry, comparing S(pCO) values from the RAD-57 to standard laboratory blood carboxyhemoglobin (COHb) measurement in emergency department patients with suspected carbon monoxide (CO) poisoning.
METHODS: This was a prospective, diagnostic accuracy study according to the Standards for the Reporting of Diagnostic Accuracy Studies criteria in consecutive adult emergency department patients with suspected CO poisoning. S(pCO) was measured with the RAD-57 simultaneously with blood sampling for laboratory blood gas analysis. We made no changes to our standard management of CO poisoning. Blood COHb > 5% for non-smokers, and > 10% for smokers were applied as the reference standard.
RESULTS: We included 93 subjects: 37 smokers and 56 non-smokers. CO poisoning was diagnosed in 26 subjects (28%). The S(pCO) values ranged from 1% to 30%, with a median of 4% (IQR 2.7-7.3%). The COHb values ranged from 0% to 34%, with a median of 5% (IQR 2-9%). The mean differences between the COHb and S(pCO) values were -0.2% ± 3.3% (95% limits of agreement of -6.7% and 6.3%) for the whole cohort, -0.7% (limits of agreement -7.7% and 6.2%) for the non-smokers, and 0.6% (limits of agreement -5.0% and 6.2%) for the smokers. The optimal thresholds for detecting CO poisoning were S(pCO) of 9% and 6% for smokers and non-smokers, respectively.
CONCLUSIONS: S(pCO) measured with the RAD-57 was not a substitute for standard blood COHb measurement. However, noninvasive pulse CO-oximetry could be useful as a first-line screening test, enabling rapid detection and management of CO-poisoned patients in the emergency department.

Entities:  

Keywords:  CO poisoning; CO-oximetry; carbon monoxide; emergency department; pulse oximetry; sensitivity; specificity

Mesh:

Substances:

Year:  2013        PMID: 23513247     DOI: 10.4187/respcare.02313

Source DB:  PubMed          Journal:  Respir Care        ISSN: 0020-1324            Impact factor:   2.258


  9 in total

Review 1.  Pulse oximetry.

Authors:  Amal Jubran
Journal:  Crit Care       Date:  2015-07-16       Impact factor: 9.097

2.  Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas.

Authors:  Makoto Onodera; Yasuhisa Fujino; Satoshi Kikuchi; Masayuki Sato; Kiyofumi Mori; Takaaki Beppu; Yoshihiro Inoue
Journal:  Scientifica (Cairo)       Date:  2016-04-30

3.  Accuracy of detection of carboxyhemoglobin and methemoglobin in human and bovine blood with an inexpensive, pocket-size infrared scanner.

Authors:  Margot P Bickler; Laura J Rhodes
Journal:  PLoS One       Date:  2018-03-07       Impact factor: 3.240

4.  Effects of Cardiorespiratory Exercise on Cognition in Older Women Exposed to Air Pollution.

Authors:  Edgardo Molina-Sotomayor; Marcelo González Orb; Francisco Pradas de la Fuente; Giovanni Carozzi Figueroa; Antonio Jesús Sánchez-Oliver; José Antonio González-Jurado
Journal:  Int J Environ Res Public Health       Date:  2019-01-16       Impact factor: 3.390

5.  Availability of Bedside and Laboratory Testing for Carbon Monoxide Poisoning in the Upper Midwestern United States.

Authors:  Thomas Masters; Brian Willenbring; Bjorn Westgard; Jon Cole; Stephen Hendriksen; Joseph Walter; Christopher Logue; Travis Olives
Journal:  West J Emerg Med       Date:  2019-04-16

Review 6.  Preparing the Intensive Care Unit for Disaster.

Authors:  Randy S Wax
Journal:  Crit Care Clin       Date:  2019-10       Impact factor: 3.598

Review 7.  Pulse oximetry: fundamentals and technology update.

Authors:  Meir Nitzan; Ayal Romem; Robert Koppel
Journal:  Med Devices (Auckl)       Date:  2014-07-08

8.  Effect of electrosurgery in the operating room on surgeons' blood indices: a simulation model and experiment on rabbits.

Authors:  Yu Hui; Jin Yan
Journal:  J Int Med Res       Date:  2018-10-21       Impact factor: 1.671

Review 9.  Effectiveness of Hyperbaric Oxygenation Versus Normobaric Oxygenation Therapy in Carbon Monoxide Poisoning: A Systematic Review.

Authors:  Sebastian Casillas; Antonio Galindo; Luis A Camarillo-Reyes; Joseph Varon; Salim R Surani
Journal:  Cureus       Date:  2019-10-15
  9 in total