Experimental validation of finite element model for proximal composite femur using optical measurements.

Lorenzo Grassi1, Sami P Väänänen, Saber Amin Yavari, Harrie Weinans, Jukka S Jurvelin, Amir A Zadpoor, Hanna Isaksson.   

Abstract

Patient-specific finite element models have been used to predict femur strength and fracture risk in individuals. Validation of the adopted finite element modelling procedure against mechanical testing data is a crucial step when aiming for clinical applications. The majority of the works available in literature used data from strain gages to validate the model, thus having up to 15 experimental measurements. Optical techniques, such as digital image correlation, can help to improve the models by providing a continuous field of deformation data over a femoral surface. The main objective of this study was to validate finite element models of six composite femora against strain data from digital image correlation, obtained during fracture tests performed in quasi-axial loading configuration. The finite element models were obtained from CT scans, by means of a semi-automatic segmentation. The principal strains both during the elastic phase and close to the fracture were compared, and showed a correlation coefficient close to 0.9. In the linear region, the slope and intercept were close to zero and unity, while for the case when fracture load was simulated, the slope decreased somewhat. The accuracy of the obtained results is comparable with the state-of-the-art literature, with the significant improvement of having around 50,000 data points for each femur. This large number of measurements allows a more comprehensive validation of the predictions by the finite element models, since thousand of points are tracked along the femoral neck and trochanter region, i.e., the sites that are most critical for femur fracture. Moreover, strain measurement biases due to the strain gage reinforcement effect, were avoided. The combined experimental-numerical approach proved to be ready for application to in-vitro tests of human cadaver femurs, thus helping to develop a suitable mechanistic fracture risk criterion.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23510970     DOI: 10.1016/j.jmbbm.2013.02.006

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  14 in total

1.  Scaling in biomechanical experimentation: a finite similitude approach.

Authors:  Raul Ochoa-Cabrero; Teresa Alonso-Rasgado; Keith Davey
Journal:  J R Soc Interface       Date:  2018-06       Impact factor: 4.118

Review 2.  Patient-Specific Bone Multiscale Modelling, Fracture Simulation and Risk Analysis-A Survey.

Authors:  Amadeus C S de Alcântara; Israel Assis; Daniel Prada; Konrad Mehle; Stefan Schwan; Lucia Costa-Paiva; Munir S Skaf; Luiz C Wrobel; Paulo Sollero
Journal:  Materials (Basel)       Date:  2019-12-24       Impact factor: 3.623

Review 3.  Additively Manufactured Scaffolds for Bone Tissue Engineering and the Prediction of their Mechanical Behavior: A Review.

Authors:  Xiang-Yu Zhang; Gang Fang; Jie Zhou
Journal:  Materials (Basel)       Date:  2017-01-10       Impact factor: 3.623

4.  Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite element model.

Authors:  C E H Scott; M J Eaton; R W Nutton; F A Wade; S L Evans; P Pankaj
Journal:  Bone Joint Res       Date:  2017-01       Impact factor: 5.853

5.  Finite Element Analysis of Different Double-Plate Angles in the Treatment of the Femoral Shaft Nonunion with No Cortical Support opposite the Primary Lateral Plate.

Authors:  Hao Zhang; Jiantao Li; Jianfeng Zhou; Lianting Li; Ming Hao; Kun Wang; Gaoxiang Xu; Chen Li; Wei Zhang; Peifu Tang
Journal:  Biomed Res Int       Date:  2018-07-31       Impact factor: 3.411

6.  A 3D-printed, personalized, biomechanics-specific beta-tricalcium phosphate bioceramic rod system: personalized treatment strategy for patients with femoral shaft non-union based on finite element analysis.

Authors:  Jian Lu; Qi-Yang Wang; Jia-Gen Sheng; Shang-Chun Guo; Shi-Cong Tao
Journal:  BMC Musculoskelet Disord       Date:  2020-07-01       Impact factor: 2.362

7.  Optimum Configuration of Cannulated Compression Screws for the Fixation of Unstable Femoral Neck Fractures: Finite Element Analysis Evaluation.

Authors:  Jiantao Li; Menglin Wang; Jianfeng Zhou; Lin Han; Hao Zhang; Chen Li; Lianting Li; Ming Hao
Journal:  Biomed Res Int       Date:  2018-12-09       Impact factor: 3.411

8.  Finite element analysis of different configurations of fully threaded cannulated screw in the treatment of unstable femoral neck fractures.

Authors:  Jiantao Li; Menglin Wang; Lianting Li; Hao Zhang; Ming Hao; Chen Li; Lin Han; Jianfeng Zhou; Kun Wang
Journal:  J Orthop Surg Res       Date:  2018-10-29       Impact factor: 2.359

9.  J-bone graft with double locking plate: a symphony of mechanics and biology for atrophic distal femoral non-union with bone defect.

Authors:  Jian Lu; Shang-Chun Guo; Qi-Yang Wang; Jia-Gen Sheng; Shi-Cong Tao
Journal:  J Orthop Surg Res       Date:  2020-04-15       Impact factor: 2.359

10.  Experimental Validation of an ITAP Numerical Model and the Effect of Implant Stem Stiffness on Bone Strain Energy.

Authors:  K Ahmed; R J Greene; W Aston; T Briggs; C Pendegrass; M Moazen; G Blunn
Journal:  Ann Biomed Eng       Date:  2020-01-23       Impact factor: 3.934

View more