Literature DB >> 23507069

The impact of leg length discrepancy on patient satisfaction and functional outcome following total hip arthroplasty.

Michael R Whitehouse1, Natalija S Stefanovich-Lawbuary, Luke R Brunton, Ashley W Blom.   

Abstract

A series of 191 patients undergoing THA with a standardised stem were studied. The effect of leg length discrepancy (LLD) on patient function (Oxford Hip Score), health measures (Short Form 12) and satisfaction (Self-Administered Patient Satisfaction Scale) at a mean 3.8 years of follow up (range 3.3 to 4.9) is reported. 8.9% of cases had shortening, 0.5% no LLD and 90.6% had lengthening. In 21.5% the LLD was more than 10mm, in 37.1% 5-10mm, and in 40.9% 0-5mm. There was no significant difference in patient reported outcome measures (PROMs) according to LLD. Correlation of recorded measurements between multiple observers was excellent (0.93). LLD following total hip arthroplasty remains common but in this series, was not correlated with PROMs.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  leg length inequality; total hip arthroplasty; treatment outcome

Mesh:

Substances:

Year:  2013        PMID: 23507069     DOI: 10.1016/j.arth.2012.12.009

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  12 in total

1.  Optimizing leg length correction in total hip arthroplasty.

Authors:  Kenji Fujita; Tamon Kabata; Yoshitomo Kajino; Hiroyuki Tsuchiya
Journal:  Int Orthop       Date:  2019-10-09       Impact factor: 3.075

2.  More than a feeling?-Overruling the preoperatively templated offset option leads to a minor offset increase in short stem total hip arthroplasty.

Authors:  Matthias Luger; Christian Stadler; Rainer Hochgatterer; Jakob Allerstorfer; Tobias Gotterbarm; Antonio Klasan
Journal:  Arch Orthop Trauma Surg       Date:  2022-01-07       Impact factor: 3.067

3.  Minimally Invasive Total Hip Arthroplasty: A Comparison of Restoring Hip Biomechanics With and Without a Traction Table.

Authors:  Florian Lenze; Florian Hinterwimmer; Lisa Fleckenstein; Igor Lazic; Dietmar Dammerer; Rüdiger VON Eisenhart-Rothe; Norbert Harrasser; Florian Pohlig
Journal:  In Vivo       Date:  2022 Jan-Feb       Impact factor: 2.155

4.  Modular tapered implants for severe femoral bone loss in THA: reliable osseointegration but frequent complications.

Authors:  Nicholas M Brown; Matthew Tetreault; Cara A Cipriano; Craig J Della Valle; Wayne Paprosky; Scott Sporer
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

5.  Total hip replacement: increasing femoral offset improves functional outcome.

Authors:  N D Clement; R S Patrick-Patel; D MacDonald; S J Breusch
Journal:  Arch Orthop Trauma Surg       Date:  2016-08-02       Impact factor: 3.067

6.  A comparison of radiographic leg-length and offset discrepancies between 2 intraoperative measurement techniques in anterior total hip arthroplasty.

Authors:  Daniel C Austin; Brendan E Dempsey; Samuel T Kunkel; Michael T Torchia; David S Jevsevar
Journal:  Arthroplast Today       Date:  2018-10-22

7.  A simple method to minimize leg length discrepancy in hip hemiarthroplasty.

Authors:  Guodong Wang; Ai Guo; Fei Yu; Bo Yang; Haomiao Yu; Naicheng Diao; Lifeng Ma; Hua Qiang; Erhong Zhao
Journal:  Clin Interv Aging       Date:  2019-09-05       Impact factor: 4.458

8.  Comparison of Clinical Outcomes, Radiological Outcomes and Bone Remodeling Outcomes Between Proximal Coated Single-Wedge New Stem and Full Coated Dual-Wedge Classic Stem in 1-Stage Bilateral Total Hip Arthroplasty.

Authors:  Hongpeng Hu; Zeming Liu; Bo Liu; Xuzhuang Ding; Sikai Liu; Tao Wu; Wenhui Ma; Yongtai Han
Journal:  Med Sci Monit       Date:  2020-01-31

9.  A Vertical Measurement System to Predict the Change in Leg Length in Total Hip Arthroplasty.

Authors:  Garth Grobler; Marc Nortje; Brendan Dower; Dave Chivers
Journal:  Arthroplast Today       Date:  2020-06-02

10.  Comparison of collum femoris-preserving stems and ribbed stems in primary total hip arthroplasty.

Authors:  Mingqing Li; Can Xu; Jie Xie; Yihe Hu; Hua Liu
Journal:  J Orthop Surg Res       Date:  2018-10-29       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.