Literature DB >> 23504300

DiagTest3Grp: An R Package for Analyzing Diagnostic Tests with Three Ordinal Groups.

Jingqin Luo1, Chengjie Xiong.   

Abstract

Medical researchers endeavor to identify potentially useful biomarkers to develop marker-based screening assays for disease diagnosis and prevention. Useful summary measures which properly evaluate the discriminative ability of diagnostic markers are critical for this purpose. Literature and existing software, for example, R packages nicely cover summary measures for diagnostic markers used for the binary case (e.g., healthy vs. diseased). An intermediate population at an early disease stage usually exists between the healthy and the fully diseased population in many disease processes. Supporting utilities for three-group diagnostic tests are highly desired and important for identifying patients at the early disease stage for timely treatments. However, application packages which provide summary measures for three ordinal groups are currently lacking. This paper focuses on two summary measures of diagnostic accuracy-volume under the receiver operating characteristic surface and the extended Youden index, with three diagnostic groups. We provide the R package DiagTest3Grp to estimate, under both parametric and nonparametric assumptions, the two summary measures and the associated variances, as well as the optimal cut-points for disease diagnosis. An omnibus test for multiple markers and a Wald test for two markers, on independent or paired samples, are incorporated to compare diagnostic accuracy across biomarkers. Sample size calculation under the normality assumption can be performed in the R package to design future diagnostic studies. A real world application evaluating the diagnostic accuracy of neuropsychological markers for Alzheimer's disease is used to guide readers through step-by-step implementation of DiagTest3Grp to demonstrate its utility.

Entities:  

Keywords:  DiagTest3Grp; R; Youden index; diagnostic test; three ordinal groups; volume under the ROC surface

Year:  2012        PMID: 23504300      PMCID: PMC3595562          DOI: 10.18637/jss.v051.i03

Source DB:  PubMed          Journal:  J Stat Softw        ISSN: 1548-7660            Impact factor:   6.440


  13 in total

1.  Nonparametric Bayesian estimation of the three-way receiver operating characteristic surface.

Authors:  Vanda Inácio; Antónia A Turkman; Christos T Nakas; Todd A Alonzo
Journal:  Biom J       Date:  2011-11       Impact factor: 2.207

2.  Measuring and estimating diagnostic accuracy when there are three ordinal diagnostic groups.

Authors:  Chengjie Xiong; Gerald van Belle; J Philip Miller; John C Morris
Journal:  Stat Med       Date:  2006-04-15       Impact factor: 2.373

3.  The inconsistency of "optimal" cutpoints obtained using two criteria based on the receiver operating characteristic curve.

Authors:  Neil J Perkins; Enrique F Schisterman
Journal:  Am J Epidemiol       Date:  2006-01-12       Impact factor: 4.897

4.  Index for rating diagnostic tests.

Authors:  W J YOUDEN
Journal:  Cancer       Date:  1950-01       Impact factor: 6.860

5.  Evaluating diagnostic tests: The area under the ROC curve and the balance of errors.

Authors:  David J Hand
Journal:  Stat Med       Date:  2010-06-30       Impact factor: 2.373

6.  Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach.

Authors:  E R DeLong; D M DeLong; D L Clarke-Pearson
Journal:  Biometrics       Date:  1988-09       Impact factor: 2.571

Review 7.  Measuring the accuracy of diagnostic systems.

Authors:  J A Swets
Journal:  Science       Date:  1988-06-03       Impact factor: 47.728

8.  The Clinical Dementia Rating (CDR): current version and scoring rules.

Authors:  J C Morris
Journal:  Neurology       Date:  1993-11       Impact factor: 9.910

9.  A method of comparing the areas under receiver operating characteristic curves derived from the same cases.

Authors:  J A Hanley; B J McNeil
Journal:  Radiology       Date:  1983-09       Impact factor: 11.105

10.  A parametric comparison of diagnostic accuracy with three ordinal diagnostic groups.

Authors:  Chengjie Xiong; Gerald van Belle; J Philip Miller; Yan Yan; Feng Gao; Kai Yu; John C Morris
Journal:  Biom J       Date:  2007-08       Impact factor: 2.207

View more
  16 in total

1.  Better see to better agree: phosphohistone H3 increases interobserver agreement in mitotic count for meningioma grading and imposes new specific thresholds.

Authors:  Eleonora Duregon; Adele Cassenti; Alessandra Pittaro; Laura Ventura; Rebecca Senetta; Roberta Rudà; Paola Cassoni
Journal:  Neuro Oncol       Date:  2015-02-01       Impact factor: 12.300

2.  Empirical likelihood confidence interval for sensitivity to the early disease stage.

Authors:  Husneara Rahman; Yichuan Zhao
Journal:  Pharm Stat       Date:  2021-12-27       Impact factor: 1.234

3.  Estimating the optimal linear combination of predictors using spherically constrained optimization.

Authors:  Priyam Das; Debsurya De; Raju Maiti; Mona Kamal; Katherine A Hutcheson; Clifton D Fuller; Bibhas Chakraborty; Christine B Peterson
Journal:  BMC Bioinformatics       Date:  2022-10-19       Impact factor: 3.307

4.  The performance of hemoglobin A1c against fasting plasma glucose and oral glucose tolerance test in detecting prediabetes and diabetes.

Authors:  Jale Karakaya; Safak Akin; Ergun Karagaoglu; Alper Gurlek
Journal:  J Res Med Sci       Date:  2014-11       Impact factor: 1.852

5.  Public Awareness of Early and Late Complications of Type 2 Diabetes - Application of Latent Profile Analysis in Determining Questionnaire Cut-Off Points.

Authors:  Nasrin Shirmohammadi; Ali Reza Soltanian; Shiva Borzouei
Journal:  Osong Public Health Res Perspect       Date:  2018-10

6.  Systematically benchmarking peptide-MHC binding predictors: From synthetic to naturally processed epitopes.

Authors:  Weilong Zhao; Xinwei Sher
Journal:  PLoS Comput Biol       Date:  2018-11-08       Impact factor: 4.475

7.  Novel application of chemical shift gradient echo in- and opposed-phase sequences in 3 T MRI for the detection of H-MRS visible lipids and grading of glioma.

Authors:  Norlisah Ramli; Azua Mohd Khairy; Pohchoo Seow; Li Kuo Tan; Jeannie Hsiu Ding Wong; Dharmendra Ganesan; Kartini Rahmat
Journal:  Eur Radiol       Date:  2015-11-11       Impact factor: 5.315

8.  bcROCsurface: an R package for correcting verification bias in estimation of the ROC surface and its volume for continuous diagnostic tests.

Authors:  Khanh To Duc
Journal:  BMC Bioinformatics       Date:  2017-11-18       Impact factor: 3.169

Review 9.  Quantitative magnetic resonance imaging and radiogenomic biomarkers for glioma characterisation: a systematic review.

Authors:  Pohchoo Seow; Jeannie Hsiu Ding Wong; Azlina Ahmad-Annuar; Abhishek Mahajan; Nor Aniza Abdullah; Norlisah Ramli
Journal:  Br J Radiol       Date:  2018-06-29       Impact factor: 3.039

10.  Accessing the discriminatory performance of FRAIL-NH in two-class and three-class frailty and examining its agreement with the frailty index among nursing home residents in mainland China.

Authors:  Feng Ge; Weiwei Liu; Minhui Liu; Siyuan Tang; Yongjin Lu; Tianxue Hou
Journal:  BMC Geriatr       Date:  2019-10-30       Impact factor: 3.921

View more