Literature DB >> 23500371

Silicon multi-nanochannel FETs to improve device uniformity/stability and femtomolar detection of insulin in serum.

Suresh Regonda1, Ruhai Tian, Jinming Gao, Serena Greene, Jiahuan Ding, Walter Hu.   

Abstract

Here we demonstrate the use of multiple Si nanochannel (NC) or nanograting (NG) instead of the conventional single nanochannel or nanowire design in biosensors. The NG devices can significantly reduce device-to-device variation, and improve device performance, e.g. higher current, higher ON/OFF ratio, smaller subthreshold slope, lower threshold voltage Vt in buffer solution. NG devices also result in higher sensor stability in buffer and diluted human serum. We believe such improvements are due to reduced discrete dopant fluctuation in the Si nanowires and biochemical noise in the solution because of the multiple-channel design. The improved devices allow us to sense pH linearly with 3-aminopropyltriethoxysilane coated devices, and to selectively detect insulin with limit of detection down to 10 fM in both buffer solution and diluted human serum without pre-purification. Published by Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23500371     DOI: 10.1016/j.bios.2013.01.027

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  9 in total

1.  Magnetic Optical Microarray Imager for Diagnosing Type of Diabetes in Clinical Blood Serum Samples.

Authors:  Vini Singh; Cassandra Rodenbaugh; Sadagopan Krishnan
Journal:  ACS Sens       Date:  2016-02-18       Impact factor: 7.711

Review 2.  Electrochemical and surface plasmon insulin assays on clinical samples.

Authors:  Vini Singh; Sadagopan Krishnan
Journal:  Analyst       Date:  2018-03-26       Impact factor: 4.616

3.  Evolvable Smartphone-Based Platforms for Point-of-Care In-Vitro Diagnostics Applications.

Authors:  François Patou; Fatima AlZahra'a Alatraktchi; Claus Kjægaard; Maria Dimaki; Jan Madsen; Winnie E Svendsen
Journal:  Diagnostics (Basel)       Date:  2016-09-03

4.  Degradation of silicon photonic biosensors in cell culture media: analysis and prevention.

Authors:  Graham J Triggs; Gareth J O Evans; Thomas F Krauss
Journal:  Biomed Opt Express       Date:  2017-05-09       Impact factor: 3.732

5.  A Novel Blood-Based Colorectal Cancer Diagnostic Technology Using Electrical Detection of Colon Cancer Secreted Protein-2.

Authors:  Minhong Jeun; Hyo Jeong Lee; Sungwook Park; Eun-Ju Do; Jaewon Choi; You-Na Sung; Seung-Mo Hong; Sang-Yeob Kim; Dong-Hee Kim; Ja Young Kang; Hye-Nam Son; Jinmyoung Joo; Eun Mi Song; Sung Wook Hwang; Sang Hyoung Park; Dong-Hoon Yang; Byong Duk Ye; Jeong-Sik Byeon; Jaewon Choe; Suk-Kyun Yang; Helen Moinova; Sanford D Markowitz; Kwan Hyi Lee; Seung-Jae Myung
Journal:  Adv Sci (Weinh)       Date:  2019-04-16       Impact factor: 16.806

6.  A Low-Power CMOS Microfluidic Pump Based on Travelling-Wave Electroosmosis for Diluted Serum Pumping.

Authors:  Pei-Wen Yen; Shiang-Chi Lin; Yi-Chun Huang; Yu-Jie Huang; Yi-Chung Tung; Shey-Shi Lu; Chih-Ting Lin
Journal:  Sci Rep       Date:  2019-10-15       Impact factor: 4.379

Review 7.  Recent advances in nanowires-based field-effect transistors for biological sensor applications.

Authors:  Rafiq Ahmad; Tahmineh Mahmoudi; Min-Sang Ahn; Yoon-Bong Hahn
Journal:  Biosens Bioelectron       Date:  2017-09-18       Impact factor: 10.618

8.  Highly transparent and flexible polyaniline mesh sensor for chemiresistive sensing of ammonia gas.

Authors:  Jingxuan Cai; Cuiping Zhang; Arshad Khan; Chuwei Liang; Wen-Di Li
Journal:  RSC Adv       Date:  2018-01-30       Impact factor: 4.036

9.  Multi-Wire Tri-Gate Silicon Nanowires Reaching Milli-pH Unit Resolution in One Micron Square Footprint.

Authors:  Enrico Accastelli; Paolo Scarbolo; Thomas Ernst; Pierpaolo Palestri; Luca Selmi; Carlotta Guiducci
Journal:  Biosensors (Basel)       Date:  2016-03-15
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.