Literature DB >> 23494277

Online solid-phase extraction-liquid chromatography-electrospray-tandem mass spectrometry determination of multiple classes of antibiotics in environmental and treated waters.

Venkata R Panditi1, Sudha Rani Batchu, Piero R Gardinali.   

Abstract

An online solid-phase extraction and liquid chromatography in combination with tandem mass spectrometry method was developed for the simultaneous determination of 31 antibiotics in drinking water, surface water and reclaimed waters. The developed methodology requires small sample volume (10 mL), very little sample preparation and total sample run time was 20 min. An Ion Max API heated electrospray ionization source operated in the positive mode with two selected reaction monitoring transitions was used per antibiotic for positive identity and quantification performed by the internal standard approach, to correct for matrix effects and any losses in the online extraction step. Method detection limits were in the range of 1.2-9.7, 2.2-15, 5.5-63 ng/L in drinking water, surface water and reclaimed waters, respectively. The method accuracy in matrix spiked samples ranged from 50-150% for the studied antibiotics. The applicability of the method was demonstrated using various environmental and reclaimed water matrices. Erythromycin was detected in more than 85% of the samples in all matrices (28-414, n.d.-199, n.d.-66 ng/L in reclaimed, river and drinking waters respectively). The other frequently detected antibiotics in reclaimed waters were nalidixic acid, clarithromycin, azithromycin, trimethoprim, and sulfamethoxazole.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23494277     DOI: 10.1007/s00216-013-6863-8

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  4 in total

1.  Ultra-high performance liquid chromatography-electrospray tandem mass spectrometry for the analysis of antibiotic residues in environmental waters.

Authors:  Qiang Xue; Yanjie Qi; Fei Liu
Journal:  Environ Sci Pollut Res Int       Date:  2015-06-24       Impact factor: 4.223

2.  [Determination of 42 antibiotic residues in seven categories in water using large volume direct injection by ultra high performance liquid chromatography-triple quadrupole mass spectrometry].

Authors:  Huijing Sun; Peiwen Li; Beibei Zhang; Huiming Chen
Journal:  Se Pu       Date:  2022-04

3.  Online solid phase extraction liquid chromatography tandem mass spectrometry (SPE-LC-MS/MS) method for the determination of sucralose in reclaimed and drinking waters and its photo degradation in natural waters from South Florida.

Authors:  Sudha Rani Batchu; Natalia Quinete; Venkata R Panditi; Piero R Gardinali
Journal:  Chem Cent J       Date:  2013-08-22       Impact factor: 4.215

4.  Prevalence of Vancomycin-Resistant Enterococci and Antimicrobial Residues in Wastewater and Surface Water.

Authors:  Kristýna Hricová; Magdaléna Röderová; Petr Fryčák; Volodymyr Pauk; Ondřej Kurka; Kristýna Mezerová; Taťána Štosová; Jan Bardoň; David Milde; Pavla Kučová; Milan Kolář
Journal:  Life (Basel)       Date:  2021-12-15
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.