Simona Hodis1, Susheil Uthamaraj, Giuseppe Lanzino, David F Kallmes, Dan Dragomir-Daescu.
Abstract
We present a computational fluid dynamics (CFD) analysis of the hemodynamic environment of an anterior communicating artery that spontaneously ruptured immediately following three-dimensional rotational angiography. Subsequent digital subtraction angiography allowed for the localization of the point of rupture within the aneurysm dome. CFD analysis demonstrated a concentrated jet that impinged directly at the site of rupture. Peak systolic pressure and wall shear stress were both maximal near the rupture location.Entities:
Keywords: Aneurysm; Angiography; Blood Flow; Hemorrhage; Subarachnoid
Mesh:
Year: 2013 PMID: 23493342 DOI: 10.1136/neurintsurg-2012-010596.rep