Literature DB >> 23489732

Stemmed TKA in a femur with a total hip arthroplasty: is there a safe distance between the stem tips?

Marc Soenen1, Matteo Baracchi, Ronny De Corte, Luc Labey, Bernardo Innocenti.   

Abstract

When a stemmed TKA is needed in a femur in which a THA is already present, choosing an appropriate length for the TKA stem is crucial. Many surgeons intuitively fear that the distance between the stem tips correlates with the femur risk for fracture (RF). However, to date, no biomechanical data to support this intuition are available. Therefore, in this study, the RF in such a configuration was determined and compared for several activities, using a finite element modeling technique. During gait and sideways falling no difference in RF among different stem lengths was shown. However, a clear threshold appears during four-point bending. Stem tip distances shorter than 110 mm dramatically increased RF and, in osteoporotic bone, will certainly lead to fracture (RF>1) and thus should be avoided.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  THA; interprosthetic femoral fracture; risk for fracture; stemmed TKA

Mesh:

Year:  2013        PMID: 23489732     DOI: 10.1016/j.arth.2013.01.010

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  10 in total

1.  Knee kinetics and kinematics: What are the effects of TKA malconfigurations?

Authors:  Silvia Pianigiani; Luc Labey; Walter Pascale; Bernardo Innocenti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-24       Impact factor: 4.342

2.  Outcome of periprosthetic femoral fractures following total hip replacement treated with polyaxial locking plate.

Authors:  M F Hoffmann; S Lotzien; T A Schildhauer
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-09-06

Review 3.  [Ipsilateral THA after stemmed TKA: Risk of interprosthetic fracture?].

Authors:  J Dexel; A Hartmann; J Pyrc; K-P Günther; J Lützner
Journal:  Orthopade       Date:  2015-07       Impact factor: 1.087

4.  The effect of different insert design congruencies on the kinematics of a mobile bearing TKA: A cadaveric study.

Authors:  Gianluca Castellarin; Edoardo Bori; Alessandra Menon; Bernardo Innocenti
Journal:  J Orthop       Date:  2022-08-10

5.  Biomechanical Analysis of the Use of Stems in Revision Total Knee Arthroplasty.

Authors:  Bernardo Innocenti; Edoardo Bori; Silvia Pianigiani
Journal:  Bioengineering (Basel)       Date:  2022-06-19

6.  Finite element analysis of malposition in bi-unicompartmental knee arthroplasty.

Authors:  Nicola Armillotta; Edoardo Bori; Bernardo Innocenti
Journal:  Arch Orthop Trauma Surg       Date:  2022-10-20       Impact factor: 2.928

7.  Incidence of and risk factors for femoral fractures in the gap between hip and knee implants.

Authors:  José Antonio Valle Cruz; Antonio Luis Urda; Laura Serrano; Francisco Alberto Rodriguez-Gonzalez; Julio Otero; Enrique Moro; Luis López-Durán
Journal:  Int Orthop       Date:  2015-09-04       Impact factor: 3.075

8.  All-polyethylene tibial components generate higher stress and micromotions than metal-backed tibial components in total knee arthroplasty.

Authors:  Jean Brihault; Alessandro Navacchia; Silvia Pianigiani; Luc Labey; Ronny De Corte; Valerio Pascale; Bernardo Innocenti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-05-10       Impact factor: 4.342

9.  Experimental and clinical analysis of the use of asymmetric vs symmetric polyethylene inserts in a mobile bearing total knee arthroplasty.

Authors:  Gianluca Castellarin; Edoardo Bori; Bernardo Innocenti
Journal:  J Orthop       Date:  2020-12-29

Review 10.  Interprosthetic femoral fractures: management challenges.

Authors:  Joshua C Rozell; Dimitri E Delagrammaticas; Ran Schwarzkopf
Journal:  Orthop Res Rev       Date:  2019-09-16
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.