BACKGROUND AND PURPOSE: Current methods of suprapubic cystostomy (SPC) catheter insertion may be difficult for patients in poor health and can result in significant morbidity and mortality. These include a highly invasive open procedure, as well as the use of the percutaneous trocar punch methods, commonly associated with short-term SPC. We present the first human experience with the Transurethral Suprapubic endo-Cystostomy (T-SPeC(®)) device, a novel disposable device used for introducing a suprapubic catheter via a retrourethral (inside-to-out) approach similar to the Lowsley technique. PATIENTS AND METHODS: Four men at St. Mary's General Hospital in Kitchener Ontario, Canada, received the T-SPeC device (model T7) under general anesthesia. RESULTS: Patients had no complications from catheterization using the T-SPeC T7 Surgical System. The mean surgical time of the four procedures was 9.7 minutes, with a range of 7.9 to 13.5 minutes, including instrument preparation and cystoscopy. All four procedures were highly accurate and rapid. There were no complications and minimal blood loss from the procedure. CONCLUSIONS: We found that the T-SPeC device allows for efficient and safe insertion of a suprapubic catheter in an outpatient setting and may be a useful addition to the urologic armamentarium. The T-SPeC Surgical System facilitates rapid and precise suprapubic catheter placement.
BACKGROUND AND PURPOSE: Current methods of suprapubic cystostomy (SPC) catheter insertion may be difficult for patients in poor health and can result in significant morbidity and mortality. These include a highly invasive open procedure, as well as the use of the percutaneous trocar punch methods, commonly associated with short-term SPC. We present the first human experience with the Transurethral Suprapubic endo-Cystostomy (T-SPeC(®)) device, a novel disposable device used for introducing a suprapubic catheter via a retrourethral (inside-to-out) approach similar to the Lowsley technique. PATIENTS AND METHODS: Four men at St. Mary's General Hospital in Kitchener Ontario, Canada, received the T-SPeC device (model T7) under general anesthesia. RESULTS:Patients had no complications from catheterization using the T-SPeC T7 Surgical System. The mean surgical time of the four procedures was 9.7 minutes, with a range of 7.9 to 13.5 minutes, including instrument preparation and cystoscopy. All four procedures were highly accurate and rapid. There were no complications and minimal blood loss from the procedure. CONCLUSIONS: We found that the T-SPeC device allows for efficient and safe insertion of a suprapubic catheter in an outpatient setting and may be a useful addition to the urologic armamentarium. The T-SPeC Surgical System facilitates rapid and precise suprapubic catheter placement.
Authors: R S Ahluwalia; N Johal; C Kouriefs; G Kooiman; Bruce S I Montgomery; R O Plail Journal: Ann R Coll Surg Engl Date: 2006-03 Impact factor: 1.891
Authors: Brian J Flynn; Robert J Larke; Paul B Knoll; Kirk M Anderson; Vassilis J Siomos; Andrew P Windsperger Journal: Int Urol Nephrol Date: 2014-11-26 Impact factor: 2.370