Literature DB >> 23488155

[Numerical simulation of LVAD inflow cannulas with different tips].

Guangmao Liu1, Jianye Zhou, Shengshou Hu, Hansong Sun, Haibo Chen, Yan Zhang, Fuliang Luo.   

Abstract

The tip structure is one of the key factors to determine the performance of left ventricular assist device (LVAD) inflow cannulas. The tip structure influences the thrombosis, hemolysis in cannula and left ventricle and suction leading to obstruction in ventricle. We designed four kinds of inflow cannulas that had different tips and built the numerical models of the four historical used inflow cannulas inserted into the apex of left ventricle. We computed the hemodynamic characteristics of inflow cannulas insertion by Fluent software. We researched the backflow, turbulent flow and pressure distribution of the four inflow cannulas. The results showed that the trumpet tipped inflow cannula had smooth flow velocity distribution without backflow or low velocity flow. The trumpet tipped inflow cannula had the best blood compatibility characteristics. The trumpet structure could prevent obstruction. The caged tipped cannula had serious turbulent flow which could possibly cause thrombosis and the low pressure near left ventricle wall and easily lead to ventricle collapse. The trumpet tipped inflow cannula has the best blood compatibility and is difficult to be obstructed. The trumpet tipped inflow cannula is fit to long-term use LVAD.

Entities:  

Mesh:

Year:  2013        PMID: 23488155

Source DB:  PubMed          Journal:  Sheng Wu Yi Xue Gong Cheng Xue Za Zhi        ISSN: 1001-5515


  3 in total

1.  Numerical study of the effect of LVAD inflow cannula positioning on thrombosis risk.

Authors:  Ge He; Lu Han; Jiafeng Zhang; Aakash Shah; David J Kaczorowski; Bartley P Griffith; Zhongjun Wu
Journal:  Comput Methods Biomech Biomed Engin       Date:  2021-10-01       Impact factor: 1.669

2.  Percutaneous Double Lumen Cannula for Right Ventricle Assist Device System: A Computational Fluid Dynamics Study.

Authors:  Francesca Condemi; Dongfang Wang; Gionata Fragomeni; Fuqian Yang; Guangfeng Zhao; Cameron Jones; Cherry Ballard-Croft; Joseph B Zwischenberger
Journal:  Biocybern Biomed Eng       Date:  2016-04-18       Impact factor: 4.314

3.  Numerical investigation of the effect of cannula placement on thrombosis.

Authors:  ChiWei Ong; Socrates Dokos; BeeTing Chan; Einly Lim; Amr Al Abed; Noor Azuan Bin Abu Osman; Suhaini Kadiman; Nigel H Lovell
Journal:  Theor Biol Med Model       Date:  2013-05-16       Impact factor: 2.432

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.