| Literature DB >> 23487415 |
Patricia Larsson1, Dag Arvidsson, Mikael Björnstedt, Bengt Isaksson, Ulf Jersenius, Hooman Motarjemi, Hans Jacobsson.
Abstract
OBJECTIVE: The sensitivity of FDG at PET examination of Hepatocellular Carcinoma (HCC) is restricted. In a few studies, all done in Oriental patients, PET-examination with (11)C-acetate has shown a higher accuracy than with FDG. In the current study, the uptake of (11)C-acetate has been compared with the uptake of FDG in the primary HCC in a cohort of Occidental patients.Entities:
Keywords: (11C)-acetate; 18F-FDG; Hepatocellular carcinoma; positron-emission; sensitivity; tomography
Year: 2012 PMID: 23487415 PMCID: PMC3590959 DOI: 10.4274/Mirt.87
Source DB: PubMed Journal: Mol Imaging Radionucl Ther
Largest tumor diameter in 42 evaluable patients with HCCvs. positive or negative finding at examinations with 11C-acetate andFDG, respectively
Matrix analysis showing number of positive PET examinationsusing FDG and 11C-acetate in 44 patients with hepatocellularcarcinoma (HCC). For statistical analysis (c.f. Results) McNemar’s testwas used
Median tracer uptake and inter-quartile range of the tumorat PET examinations using FDG and 11C-acetate in all patients withhepatocellular carcinoma. SUV’s and values vs. mean surroundingliver activity and vs. mean mediastinal blood activity, respectively, areshown
Figure 1PET examinations (A-P MIP’s) with FDG (A) and 11C-acetate (B) ina 58-year old woman with a large HCC (arrows). This illustrates theparadoxical effect of the higher uptake of 11C-acetate by the surroundingliver tissue compared to the uptake of FDG. In this patient, the tumorSUVmean was 3.2 for both tracers. SUVmean for FDG of surrounding liver tissue (A)was 1.1 and SUVmean for 11C-acetate (B) was 2.6. Thiscorresponded to tumor-to-background ratios of 3.0 and 1.2, respectively
Median tracer uptake and inter-quartile range at PETexaminations in hepatocellular carcinomas being positive using FDGor 11C-acetate. SUV’s and values vs. surrounding liver activity and vs.mediastinal blood pool activity, respectively, are shown. Incomparisons between the groups, there are both dependent andindependent observations why? no statistical analyses
Figure 2Transversal sections at the same level from PET examinationswith FDG (A) and 11C-acetate (B) in a 76-year old woman with a large HCCdiagnosed according to the Barcelona criteria. The figure illustrates adiscordant uptake between the two tracers. Red delineates the 50% isocontourlevel of FDG and blue delineates the 50% isocontour level of 11C-acetate
Figure 3Transversal sections at the same level from PET examinationswith FDG (A) and 11C-acetate (B) in a 70-year old man with a large, well differentiatedHCC confirmed at histopathology after surgical resection.The figure illustrates a discordant uptake between the two tracers. Reddelineates the 50% isocontour level of FDG and blue delineates the 50%isocontour level of 11C-acetate
Correlation between the uptake of 11C-acetate and of FDG at PET examination in patients with hepatocellular carcinoma (HCC). Allevaluable patients and patients positive with both tracers, respectively, were assessed using Spearman Rank correlation analysis
Detectability (percentage) of primary hepatocellular carcinoma (HCC) at PET using FDG and 11C-acetate in the current study comparedto previous studies. n=number of patients studied