Literature DB >> 23486641

The effect of the excisional biopsy in the detection of the sentinel lymph node by lymphoscintigraphy and intraoperative gamma probe in breast cancer.

Pelin Arıcan1, Irfan Peksoy, Seniha Naldöken, Betül Bozkurt.   

Abstract

OBJECTIVE: Sentinel lymph node (SLN) scintigraphy is used widespread in breast cancer, but the effect of the radionuclide agent, injection technique, the method of biopsy, tumor localization, breast size remain controversial. We examined the effects of the excisional biopsy in the rate of the SLN identification with lymphoscintigraphy (LS) and intraoperative gamma probe (IGP).
MATERIAL AND METHODS: One hundred patients (age range: 28-79 yr) with breast cancer were included in the study. They consisted of two groups: Group 1; there were 58 patients without excisional biopsy Group 2; there were 42 patients with excisional biopsy LS: 2 hours before the operation, 37 MBq/ ml Tc 99m colloidal rhenium sulphide was injected at the periaerolar region intradermally Anterior and lateral static images were acquired. IGP: The hot spot of greatest radioactivity were marked on the skin during the surgery with IGP and removed. Excised SLNs were examined with frozen section. After that histopathological and immunohistochemical examinations were performed.
RESULTS: SLNs were found in all patients in group 1 (100%), in 39 patients of group 2 (93%) with LS. SLNs were excised in 57 of the 58 patients of group 1 (98%), in 38 of the 42 patients of group 2 (90%) with IGF. Metastases were found in SLNs in 27 patients (28%). Axillary dissection was performed in these patients.
CONCLUSION: According to results of our study the excisional biopsy was not the only factor but also other factors such as breast mass, calcified or metastatic lymph node may be affected the success rate of the SLN. CONFLICT OF INTEREST: None declared.

Entities:  

Keywords:  Breast cancer; intraoperative gamma probe; lymphoscintigraphy; sentinel lymph node

Year:  2011        PMID: 23486641      PMCID: PMC3590949          DOI: 10.4274/MIRT.28

Source DB:  PubMed          Journal:  Mol Imaging Radionucl Ther


INTRODUCTION

Breast cancer is still a major health problem in women. Axillary lymph node status is the most important prognostic factor in patients with early breast cancer (1,2). Axillary lymph node metastasis is found approximately in 40% of these patients. In the remaining 60%, there is no therapeutic benefit from total axillary lymphadenectomy (3,4). However, the potential morbidity after axillary dissection is relatively high and may cause significant complications (5,6). The sentinel lymph node (SLN) is the first lymph node to which the tumor is drained and it is the first to become involved in a metastasis from the tumor (7). SLN biopsy is the best procedure for the axillary lymph node status. The identification of the SLN plays an important role in surgical planning and in the management of breast cancer (7,8). There have been different techniques in the detection of the SLN mapping such as blue dye (9), radionuclide methods (lymphoscintigraphy and intraoperative gamma probe) (10,11,12,13,14) and simultaneous use of both. (12,13,14). Although the SLN biopsy is used widespread; the best agent, injection technique, the method of biopsy, tumor localization and breast size remain controversial. Surgeon's experience is another factor in the determination of SLN. The previous excisional biopsy may affect the visualization of lymphatic drainage and SLN due to distruption of normal lymphatic pathways (15,16,17,18,19). In our study, we investigated the effect of the excisional biopsy in the rate of the sentinel lymph node identification with lymphoscintigraphy and intraoperative gamma probe.

MATERIALS AND METHODS

Patient Population: One hundred patients (age range: 28-79 yr; mean age: 53.5±25.5) with stage I-II breast cancer were included in the study. None of them had axillary palpable lymph nodes, multicentric tumor and history of prior radiotherapy. Informed consent was obtained from all patients. The characteristics of the patients are summarized in Table 1. The study consisted of two groups: Group 1; there were 58 patients without excisional biopsy. Group 2; there were 42 patients with excisional biopsy.
Table 1

The characteristics of the patients

Lymphoscintigraphy (LS): On the day before the operation, Tc 99m colloidal rhenium sulphide (Nanocis, CIS) was injected at the periareolar region intradermally at four different locations in two groups. Total injection activity was 37 MBq/ml. After injection, each patient was instructed to massage the injection side for a few minutes. Anterior and lateral static images were obtained for 5 minutes using a single head gamma camera (Mediso or Elscint SPX) equipped with a low energy-high resolution collimator. The energy peak was set on 140 keV and 20% window. Counts were collected on a 256x256 matrix. If SLN was not visualized, delayed imaging was done at 2 hours after injection. However, delayed static images could not be taken from some patients because of the hurry of the operating room. Images were evaluated qualitatively by 2 nuclear medicine specialists. Intraoperative gamma probe (IGP): Intraoperative localization of SLN was performed with IGP (Europrobe). All operations were performed by the same surgeon. The IGP was covered with a sterile endoscopic probe cover. The breast mass, axillary, supraclavicular, infraclavicular and internal mammary regions were investigated with IGP before the incision. The hot spot of greatest radioactivity was marked on the skin. The radioactive node(s) were removed and also counted ex vivo. Excised SLNs were sent to the pathologist for frozen section examination. If the frozen section was positive for metastases, total axillary dissection was performed. Pathological examination: Histopathological examination was performed by microscopic examination with hematoxylin- eosin and immunohistochemical techniques. Statistical Analysis Mann-Whitney U was used to compare two groups.

RESULTS

The Results of LS and IGP Group 1: The results of LS and IGP in Group 1 are shown in Table 2. Lymphatic drainage through the axillary region and SLNs were found in all patients with LS. The detection rate was 100% (Figure 1). Only one patient showed internal mammarial drainage. SLNs were detected in 57 of the 58 patients with IGF! The detection rate was 98%. SLN was not detected with IGP in one patient (false negative). False positive results were not found with IGP.
Figure 1

A patient without excisional biopsy. Anterior (A) and right lateral(B) static images show four SLNs (black arrow) and lymphatic pathways(white arrow)

Group 2: The results of LS and IGP in Group 2 are shown in Table 2. Lymphatic drainage through the axillary region and SLNs were found in 39 of 42 patients with LS. The detection rate was 93% (Figure 2). In 3 patients, no SLN was detected with LS. None of the patients showed extra-axillary drainage. SLNs were detected in 38 of the 42 patients with IGP The detection rate was 90%. In 4 patients, no SLN was detected with IGP (one patient false negative, 3 patients true negative). False positive results were not found with IGF!
Figure 2

The patient with excisional biopsy. (A) There are three SLN inanterior image (black arrow) (B) lymphatic drainage pathway (white arrow)and SLN (black arrow) in left lateral image

There was no statistical difference between two groups (p>0.05).All SLNs (except 2 patients) which are found with LS and IGP were excised in both groups. In 5 of the 100 patients (one patient in group 1, four patients in group 2), SLNs were not detected with IGP Characteristics of these patients are presented in Table 3. In 3 of 5 patients, SLN and lymphatic drainage were not detected with both LS and IGP These patients were in Group 2. In 2 of 5 patients, SLNs and lymphatic drainage were found with LS, but they were not detected with IGP (one patient in group 1, one patient in group 2).
Table 2

The results of SLN identification in Group 1 and Group 2

Pathology Results: Metastases were not found in excised SLNs in 68 of 95 patients by histochemical and immunohistochemical examination (72%). However, metastases were found in SLNs in 27 patients (28%). Axillary dissection was performed in these patients. Axillary metastasis was found in 15 patients (15%).

DISCUSSION

Breast cancer is a major malignancy for women and the pathologic status of axillary lymph nodes are very important determinants of prognosis. Axillary node dissection is an invasive and complicated procedure for staging the axillary area and has no benefits for therapy. The pathologic examination of the SLN is essential to evaluate the status of the axillary region. If it is not metastatic, axillary lymphadenectomy may not be necessary. LS, blue dye and IGP may be used separately or combined to detect lymphatic drainage and SLN(12,13,14). Although LS and IGP are increasingly used for detection of SLN, injection site, type of radioactive agent, volume, dose and timing are still controversy. In the literature, several authors have reported that previous biopsy had no effect on the success of the SLN identification (15,19). However some studies hypothesize that biopsy cavity may affect the SLN identification rate (15,16,17,18,19). The large excisional biopsy cavity may cause distruption of normal anatomic lymphatic pathways. Therefore, the detection rate of SLN may be reduced. In our study; the comparison of Group 1 and Group 2 was not statistically different. The detection rate of LS and IGP in Group 1 and Group 2 were found 100%, 98%,95% and 90%, respectively. The identification rate of SLNs by using LS and IGP was compatible with the results of the literature (12,13,14,20,21). Different injection techniques are used in the detection of SLN. Currently, periareolar intradermal injection techniques are preferred because of the rapid visualization and high rate of SLN detection, regardless of the localization of the tumor (18,21). The success rate of SLN detection is higher in superficial injections such as intradermal and subdermal than deeper injections such as peritumoral and intratumoral (22). On the other hand, the detection rate of internal mammarian drainage is higher with deeper injection than superficial injection (18,19,20,21,22). The periareolar injection can eliminate the effects of excisional biopsy, nonpalpabl tumor and multicentric tumor (23). Therefore, we preferred periareoler injection technique regardless of the type of biopsy. Other injection techniques such as peritumoral injection can affect identification of SLN, due to excisional cavity. In one patient, internal mammarian drainage was seen with LS in Group 1. Internal mammarian drainage did not change the surgery planning. The detection rate of the extraaxillary drainage was very low in our study. This situation can be explained that delayed static images could not be taken in some patients, because of the hurry of the operating room. These patients were sent to surgery earlier than usual. The success rate of extraaxillary lymphatic drainage with periareolar intradermal radioactivity injection is lower than other injection techniques (18,19,20,21,22). Some SLNs were not detected with LS and IGP SLN activity may be suppressed by the injection site activity. Small size, calcification or full of metastatic cells in the lymph node may also prevent visibility. The SLN may not be detected with IGP when the operation time is too late (18,19,20,21,22). In our study, SLN and lymphatic drainage were not detected with both LS and IGP in 3 of 5 patients. These patients were in Group 2. SLNs and axillary metastasis were found by pathological examination in these patients. SLNs could not be detected with LS and IGP when lymph nodes are full of metastatic cells. In 2 of 5 patients, SLNs and lymphatic drainage were found with LS, but they were not detected with IGP (one patient in group 1, one patient in Group 2). We thought that, this status could be based on late operation time in these patients.

CONCLUSION

SLN biopsy is the best procedure to determine the axillary lymph node status. LS and IGP have important roles for the detection of the SLN. There are many factors affecting the detection of SLN. One of these factors may be previous excisional biopsy. According to the results of our study, the excisional biopsy does not affect the success rate of the SLN, if radiopharmaceutical is injected at the periareolar region.
Table 3

The results of the patients with no SLN detected with IGP

  21 in total

1.  Sentinel node in breast cancer procedural guidelines.

Authors:  John Buscombe; Giovanni Paganelli; Zeynep E Burak; Wendy Waddington; Jean Maublant; Enrique Prats; Holger Palmedo; Orazio Schillaci; Lorenzo Maffioli; M Lassmann; Carlo Chiesa; Emilio Bombardieri; Arturo Chiti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-12       Impact factor: 9.236

2.  Lymphoscintigraphy and radioguided biopsy of the sentinel axillary node in breast cancer.

Authors:  C De Cicco; M Cremonesi; A Luini; M Bartolomei; C Grana; G Prisco; V Galimberti; P Calza; G Viale; U Veronesi; G Paganelli
Journal:  J Nucl Med       Date:  1998-12       Impact factor: 10.057

3.  Identification and biopsy of the sentinel lymph node in breast cancer.

Authors:  B A Kapteijn; O E Nieweg; J L Petersen; E J Rutgers; A A Hart; J A van Dongen; B B Kroon
Journal:  Eur J Surg Oncol       Date:  1998-10       Impact factor: 4.424

4.  Sentinel node biopsy in breast cancer. A promising technique, but it should not be introduced without proper trials.

Authors:  M Dixon
Journal:  BMJ       Date:  1998-08-01

5.  Intradermal blue dye to identify sentinel lymph-node in breast cancer.

Authors:  P J Borgstein; S Meijer; R Pijpers
Journal:  Lancet       Date:  1997-06-07       Impact factor: 79.321

6.  Impact of lymphoscintigraphy on sentinel node identification with technetium-99m-colloidal albumin in breast cancer.

Authors:  R Pijpers; S Meijer; O S Hoekstra; G J Collet; E F Comans; R P Boom; P J van Diest; G J Teule
Journal:  J Nucl Med       Date:  1997-03       Impact factor: 10.057

7.  The value of combined peritumoral and subdermal injection techniques for lymphoscintigraphy in detection of sentinel lymph node in breast cancer.

Authors:  Yasemin Sanli; Kezban Berberoglu; Cuneyt Turkmen; Vahid Ozmen; Mahmut Muslumanoglu; Abdullah Igci; Oktar Asoglu; Mustafa Kecer; Sitki Tuzlali; Sema Cantez; Ayse Mudun
Journal:  Clin Nucl Med       Date:  2006-11       Impact factor: 7.794

8.  Sentinel lymph node biopsy in breast cancer: guidelines and pitfalls of lymphoscintigraphy and gamma probe detection.

Authors:  P J Borgstein; R Pijpers; E F Comans; P J van Diest; R P Boom; S Meijer
Journal:  J Am Coll Surg       Date:  1998-03       Impact factor: 6.113

9.  The sentinel node biopsy after previous breast surgery: preliminary results on 543 patients treated at the European Institute of Oncology.

Authors:  Alberto Luini; Viviana Galimberti; Giovanna Gatti; Paolo Arnone; Anna Rita Vento; Giuseppe Trifirò; Giuseppe Viale; Nicole Rotmensz; Julia Rodriguez Fernandez; Daniela Gilardi; Giovanni Paganelli
Journal:  Breast Cancer Res Treat       Date:  2005-01       Impact factor: 4.872

10.  Complications of axillary lymph node dissection for carcinoma of the breast: a report based on a patient survey.

Authors:  M A Warmuth; G Bowen; L R Prosnitz; L Chu; G Broadwater; B Peterson; G Leight; E P Winer
Journal:  Cancer       Date:  1998-10-01       Impact factor: 6.860

View more
  2 in total

1.  Sentinel Lymph Node Detection by 3D Freehand Single-Photon Emission Computed Tomography in Early Stage Breast Cancer.

Authors:  Salih Sinan Gültekin; Ahmet Oğuz Hasdemir; Serhat Tokgöz; Gülay Özgehan; Hakan Güzel; Cüneyt Yücesoy; Emine Öztürk; Ata Türker Arıkök
Journal:  Mol Imaging Radionucl Ther       Date:  2016-06-05

2.  Clinical study of combined application of indocyanine green and methylene blue for sentinel lymph node biopsy in breast cancer.

Authors:  Chenguang Zhang; Yongtao Li; Xiaowen Wang; Mingshuai Zhang; Weihua Jiang; Jianghua Ou
Journal:  Medicine (Baltimore)       Date:  2021-04-16       Impact factor: 1.817

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.