Literature DB >> 23482880

Uniform enhancement of optical micro-angiography images using Rayleigh contrast-limited adaptive histogram equalization.

Siavash Yousefi1, Jia Qin, Zhongwei Zhi, Ruikang K Wang.   

Abstract

Optical microangiography is an imaging technology that is capable of providing detailed functional blood flow maps within microcirculatory tissue beds in vivo. Some practical issues however exist when displaying and quantifying the microcirculation that perfuses the scanned tissue volume. These issues include: (I) Probing light is subject to specular reflection when it shines onto sample. The unevenness of the tissue surface makes the light energy entering the tissue not uniform over the entire scanned tissue volume. (II) The biological tissue is heterogeneous in nature, meaning the scattering and absorption properties of tissue would attenuate the probe beam. These physical limitations can result in local contrast degradation and non-uniform micro-angiogram images. In this paper, we propose a post-processing method that uses Rayleigh contrast-limited adaptive histogram equalization to increase the contrast and improve the overall appearance and uniformity of optical micro-angiograms without saturating the vessel intensity and changing the physical meaning of the micro-angiograms. The qualitative and quantitative performance of the proposed method is compared with those of common histogram equalization and contrast enhancement methods. We demonstrate that the proposed method outperforms other existing approaches. The proposed method is not limited to optical microangiography and can be used in other image modalities such as photo-acoustic tomography and scanning laser confocal microscopy.

Keywords:  Optical coherence tomography; contrast-limited adaptive histogram equalization; optical micro-angiography; specular reflection

Year:  2013        PMID: 23482880      PMCID: PMC3591495          DOI: 10.3978/j.issn.2223-4292.2013.01.01

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  21 in total

Review 1.  Image processing algorithms for digital mammography: a pictorial essay.

Authors:  E D Pisano; E B Cole; B M Hemminger; M J Yaffe; S R Aylward; A D Maidment; R E Johnston; M B Williams; L T Niklason; E F Conant; L L Fajardo; D B Kopans; M E Brown; S M Pizer
Journal:  Radiographics       Date:  2000 Sep-Oct       Impact factor: 5.333

2.  Optical microangiography provides an ability to monitor responses of cerebral microcirculation to hypoxia and hyperoxia in mice.

Authors:  Yali Jia; Peng Li; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2011-09       Impact factor: 3.170

3.  Directional blood flow imaging in volumetric optical microangiography achieved by digital frequency modulation.

Authors:  Ruikang K Wang
Journal:  Opt Lett       Date:  2008-08-15       Impact factor: 3.776

4.  Three dimensional optical angiography.

Authors:  Ruikang K Wang; Steven L Jacques; Zhenhe Ma; Sawan Hurst; Stephen R Hanson; Andras Gruber
Journal:  Opt Express       Date:  2007-04-02       Impact factor: 3.894

5.  Depth-resolved imaging of capillary networks in retina and choroid using ultrahigh sensitive optical microangiography.

Authors:  Ruikang K Wang; Lin An; Peter Francis; David J Wilson
Journal:  Opt Lett       Date:  2010-05-01       Impact factor: 3.776

6.  Eigendecomposition-based clutter filtering technique for optical micro-angiography.

Authors:  Siavash Yousefi; Zhongwei Zhi; Ruikang K Wang
Journal:  IEEE Trans Biomed Eng       Date:  2011-05-12       Impact factor: 4.538

7.  Ultrahigh sensitive optical microangiography for in vivo imaging of microcirculations within human skin tissue beds.

Authors:  Lin An; Jia Qin; Ruikang K Wang
Journal:  Opt Express       Date:  2010-04-12       Impact factor: 3.894

8.  Using ultrahigh sensitive optical microangiography to achieve comprehensive depth resolved microvasculature mapping for human retina.

Authors:  Lin An; Tueng T Shen; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2011-10       Impact factor: 3.170

9.  Ultrahigh-resolution optical coherence tomography in glaucoma.

Authors:  Gadi Wollstein; Leila A Paunescu; Tony H Ko; James G Fujimoto; Andrew Kowalevicz; Ingmar Hartl; Siobahn Beaton; Hiroshi Ishikawa; Cynthia Mattox; Omah Singh; Jay Duker; Wolfgang Drexler; Joel S Schuman
Journal:  Ophthalmology       Date:  2005-02       Impact factor: 12.079

Review 10.  Imaging of angiogenesis: from microscope to clinic.

Authors:  Donald M McDonald; Peter L Choyke
Journal:  Nat Med       Date:  2003-06       Impact factor: 53.440

View more
  9 in total

1.  Volumetric cutaneous microangiography of human skin in vivo by VCSEL swept-source optical coherence tomography.

Authors:  Woo June Choi; Ruikang K Wang
Journal:  Quantum Elec (Woodbury)       Date:  2014       Impact factor: 1.022

2.  Tail artifact removal in OCT angiography images of rodent cortex.

Authors:  Utku Baran; Woo June Choi; Yuandong Li; Ruikang K Wang
Journal:  J Biophotonics       Date:  2016-09-07       Impact factor: 3.207

3.  Motion artifact and background noise suppression on optical microangiography frames using a naïve Bayes mask.

Authors:  Roberto Reif; Utku Baran; Ruikang K Wang
Journal:  Appl Opt       Date:  2014-07-01       Impact factor: 1.980

4.  Segmentation and quantification of blood vessels for OCT-based micro-angiograms using hybrid shape/intensity compounding.

Authors:  Siavash Yousefi; Ting Liu; Ruikang K Wang
Journal:  Microvasc Res       Date:  2014-10-02       Impact factor: 3.514

5.  Analysis of cross-sectional image filters for evaluating nonaveraged optical microangiography images.

Authors:  Roberto Reif; Siavash Yousefi; Woo June Choi; Ruikang K Wang
Journal:  Appl Opt       Date:  2014-02-10       Impact factor: 1.980

6.  Robust principal component analysis in optical micro-angiography.

Authors:  Nhan Le; Shaozhen Song; Qinqin Zhang; Ruikang K Wang
Journal:  Quant Imaging Med Surg       Date:  2017-12

7.  OCT-based label-free in vivo lymphangiography within human skin and areola.

Authors:  Utku Baran; Wan Qin; Xiaoli Qi; Goknur Kalkan; Ruikang K Wang
Journal:  Sci Rep       Date:  2016-02-19       Impact factor: 4.379

8.  Normalization of optical fluence distribution for three-dimensional functional optoacoustic tomography of the breast.

Authors:  Seonyeong Park; Frank J Brooks; Umberto Villa; Richard Su; Mark A Anastasio; Alexander A Oraevsky
Journal:  J Biomed Opt       Date:  2022-03       Impact factor: 3.758

9.  Software-Based Phase Control, Video-Rate Imaging, and Real-Time Mosaicing With a Lissajous-Scanned Confocal Microscope.

Authors:  Nathan O Loewke; Zhen Qiu; Michael J Mandella; Robert Ertsey; Adrienne Loewke; Lisa A Gunaydin; Eben L Rosenthal; Christopher H Contag; Olav Solgaard
Journal:  IEEE Trans Med Imaging       Date:  2019-09-27       Impact factor: 10.048

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.