Effects of condensate in the exhalation limb of neonatal circuits on airway pressure during bubble CPAP.

Tiffany M Youngquist1, C Peter Richardson, Robert M Diblasi.   

Abstract

BACKGROUND: Bubble CPAP is frequently used in spontaneously breathing infants with lung disease. Often bubble CPAP systems lack pressure alarms and pressure-release valves. We observed a large volume of condensate in the exhalation limb of a patient circuit and conducted a series of experiments to test the hypothesis that accumulated condensate could affect delivered pressures.
METHODS: An anatomically accurate nasal airway model of a preterm infant was attached to a spontaneously breathing lung model. A bubble CPAP system was attached to the nasal airway with bi-nasal short prongs, and the rate of fluid condensation was measured. Next, tracheal pressures were monitored digitally to detect changes in airway pressure related to condensate accumulation. Measurements were obtained with volumes of 0, 5, 10, 15, and 20 mL of water in the exhalation limb, at flows of 4, 6, 8, and 10 L/min. Measurements with 20 mL in the exhalation limb were recorded with and without a pressure-relief valve in the circuit.
RESULTS: The rate of condensate accumulation was 3.8 mL/h. At volumes of ≥ 10 mL, noticeable alterations in the airway pressure waveforms and significant increases in mean tracheal pressure were observed. The pressure-relief valve effectively attenuated peak tracheal pressure, but only decreased mean pressure by 0.5-1.5 cm H2O.
CONCLUSIONS: Condensate in the exhalation limb of the patient circuit during bubble CPAP can significantly increase pressure delivered to the patient. The back and forth movement of this fluid causes oscillations in airway pressure that are much greater than the oscillations created by gas bubbling out the exhalation tube into the water bath. We recommend continuously monitoring pressure at the nasal airway interface, placing an adjustable pressure-relief valve in the circuit, set to 5 cm H2O above the desired mean pressure, and emptying fluid from the exhalation limb every 2-3 hours.

Entities:  

Keywords:  airway pressure; bubble CPAP; condensate; lung protection; maintenance; neonatal intensive care; noninvasive ventilation; patient safety; resistance

Mesh:

Year:  2013        PMID: 23481441     DOI: 10.4187/respcare.02322

Source DB:  PubMed          Journal:  Respir Care        ISSN: 0020-1324            Impact factor:   2.258


  8 in total

1.  Characterizing the Effects of Nasal Prong Interfaces on Aerosol Deposition in a Preterm Infant Nasal Model.

Authors:  Karl Bass; Mohammad A M Momin; Connor Howe; Ghali Aladwani; Sarah Strickler; Arun V Kolanjiyil; Michael Hindle; Robert M DiBlasi; Worth Longest
Journal:  AAPS PharmSciTech       Date:  2022-04-19       Impact factor: 3.246

2.  In Vitro Analysis of Nasal Interface Options for High-Efficiency Aerosol Administration to Preterm Infants.

Authors:  Connor Howe; Mohammad A M Momin; Karl Bass; Ghali Aladwani; Serena Bonasera; Michael Hindle; Philip Worth Longest
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2022-02-14       Impact factor: 3.440

3.  Preclinical Assessment of Nebulized Surfactant Delivered through Neonatal High Flow Nasal Cannula Respiratory Support.

Authors:  Francesca Ricci; Arianna Mersanne; Matteo Storti; Marcello Nutini; Giulia Pellicelli; Angelo Carini; Ilaria Milesi; Marta Lombardini; Raffaele L Dellacà; Merran A Thomson; Xabier Murgia; Anna Lavizzari; Federico Bianco; Fabrizio Salomone
Journal:  Pharmaceutics       Date:  2022-05-20       Impact factor: 6.525

Review 4.  Non-invasive Respiratory Support of the Premature Neonate: From Physics to Bench to Practice.

Authors:  Ibrahim Sammour; Sreenivas Karnati
Journal:  Front Pediatr       Date:  2020-05-08       Impact factor: 3.418

5.  Mechanisms of nasal high flow therapy in newborns.

Authors:  Pavel Mazmanyan; Mari Darakchyan; Maximilian I Pinkham; Stanislav Tatkov
Journal:  J Appl Physiol (1985)       Date:  2020-02-20

6.  An evaluation of temperature stability and resistance in neonatal ventilator circuits.

Authors:  Jennifer A Ruppert; Neil L McNinch; Teresa A Volsko
Journal:  Can J Respir Ther       Date:  2021-01-29

Review 7.  Aerosol drug delivery to spontaneously-breathing preterm neonates: lessons learned.

Authors:  Federico Bianco; Fabrizio Salomone; Ilaria Milesi; Xabier Murgia; Sauro Bonelli; Elena Pasini; Raffaele Dellacà; Maria Luisa Ventura; Jane Pillow
Journal:  Respir Res       Date:  2021-02-26

8.  Dangerous Pressurization and Inappropriate Alarms during Water Occlusion of the Expiratory Circuit of Commonly Used Infant Ventilators.

Authors:  Murray Hinder; Aldo Perdomo; Mark Tracy
Journal:  PLoS One       Date:  2016-04-26       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.