Literature DB >> 23475813

High speed 3D overhauser-enhanced MRI using combined b-SSFP and compressed sensing.

Mathieu Sarracanie1, Brandon D Armstrong, Jason Stockmann, Matthew S Rosen.   

Abstract

PURPOSE: Overhauser-enhanced MRI is a promising technique for imaging the distribution and dynamics of free radicals. A key challenge for Overhauser-enhanced MRI is attaining high spatial and temporal resolution while simultaneously limiting resonator and sample heating due to the long, high power radio-frequency pulses needed to saturate the electron resonance.
METHODS: The approach presented here embeds EPR pulses within a balanced steady state free precession sequence. Unlike other Overhauser-enhanced MRI methods, no separate Overhauser prepolarization step is required. This steady-state approach also eliminates the problem of time-varying Overhauser-enhanced signal and provides constant polarization in the sample during the acquisition. A further increase in temporal resolution was achieved by incorporating undersampled k-space strategies and compressed sensing reconstruction.
RESULTS: We demonstrate 1 × 2 × 3.5 mm(3) resolution at 6.5 mT across a 54 × 54 × 110 mm(3) sample in 33 s while sampling 30% of k-space.
CONCLUSION: The work presented here overcomes the main limitations of Overhauser enhanced MRI as previously described in the literature, drastically improving speed and resolution, and enabling new opportunities for the measurement of free radicals in living organisms, and for the study of dynamic processes such as metabolism and flow.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2014        PMID: 23475813     DOI: 10.1002/mrm.24705

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  17 in total

1.  In situ and ex situ low-field NMR spectroscopy and MRI endowed by SABRE hyperpolarization.

Authors:  Danila A Barskiy; Kirill V Kovtunov; Igor V Koptyug; Ping He; Kirsten A Groome; Quinn A Best; Fan Shi; Boyd M Goodson; Roman V Shchepin; Milton L Truong; Aaron M Coffey; Kevin W Waddell; Eduard Y Chekmenev
Journal:  Chemphyschem       Date:  2014-11-03       Impact factor: 3.102

2.  The MR Cap: A single-sided MRI system designed for potential point-of-care limited field-of-view brain imaging.

Authors:  Patrick C McDaniel; Clarissa Zimmerman Cooley; Jason P Stockmann; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2019-06-23       Impact factor: 4.668

3.  Long-lived spin States for low-field hyperpolarized gas MRI.

Authors:  Kirill V Kovtunov; Milton L Truong; Danila A Barskiy; Igor V Koptyug; Aaron M Coffey; Kevin W Waddell; Eduard Y Chekmenev
Journal:  Chemistry       Date:  2014-09-26       Impact factor: 5.236

4.  Imaging short-lived reactive oxygen species (ROS) with endogenous contrast MRI.

Authors:  Rong-Wen Tain; Alessandro M Scotti; Weiguo Li; Xiaohong Joe Zhou; Kejia Cai
Journal:  J Magn Reson Imaging       Date:  2017-05-15       Impact factor: 4.813

5.  In vivo imaging of prodromal hippocampus CA1 subfield oxidative stress in models of Alzheimer disease and Angelman syndrome.

Authors:  Bruce A Berkowitz; Jacob Lenning; Nikita Khetarpal; Catherine Tran; Johnny Y Wu; Ali M Berri; Kristin Dernay; E Mark Haacke; Fatema Shafie-Khorassani; Robert H Podolsky; John C Gant; Shaniya Maimaiti; Olivier Thibault; Geoffrey G Murphy; Brian M Bennett; Robin Roberts
Journal:  FASEB J       Date:  2017-06-07       Impact factor: 5.191

6.  High-resolution hyperpolarized in vivo metabolic 13C spectroscopy at low magnetic field (48.7mT) following murine tail-vein injection.

Authors:  Aaron M Coffey; Matthew A Feldman; Roman V Shchepin; Danila A Barskiy; Milton L Truong; Wellington Pham; Eduard Y Chekmenev
Journal:  J Magn Reson       Date:  2017-06-15       Impact factor: 2.229

7.  NMR hyperpolarization techniques for biomedicine.

Authors:  Panayiotis Nikolaou; Boyd M Goodson; Eduard Y Chekmenev
Journal:  Chemistry       Date:  2014-12-03       Impact factor: 5.236

8.  High-resolution 3D proton MRI of hyperpolarized gas enabled by parahydrogen and Rh/TiO2 heterogeneous catalyst.

Authors:  Kirill V Kovtunov; Danila A Barskiy; Aaron M Coffey; Milton L Truong; Oleg G Salnikov; Alexander K Khudorozhkov; Elizaveta A Inozemtseva; Igor P Prosvirin; Valery I Bukhtiyarov; Kevin W Waddell; Eduard Y Chekmenev; Igor V Koptyug
Journal:  Chemistry       Date:  2014-06-24       Impact factor: 5.236

Review 9.  Recent Developments of Nanodiamond Quantum Sensors for Biological Applications.

Authors:  Yingke Wu; Tanja Weil
Journal:  Adv Sci (Weinh)       Date:  2022-03-27       Impact factor: 17.521

10.  Fast Room Temperature Very Low Field-Magnetic Resonance Imaging System Compatible with MagnetoEncephaloGraphy Environment.

Authors:  Angelo Galante; Raffaele Sinibaldi; Allegra Conti; Cinzia De Luca; Nadia Catallo; Piero Sebastiani; Vittorio Pizzella; Gian Luca Romani; Antonello Sotgiu; Stefania Della Penna
Journal:  PLoS One       Date:  2015-12-02       Impact factor: 3.240

View more