Abstract
Indoor microbial communities play an important role in everyday human health, especially in the intensive care units (ICUs) of hospitals. We used amplicon pyrosequencing to study the ICU microbiome and were able to detect diverse sequences, in comparison to the currently used standard cultivation technique that only detected 2.5% of the total bacterial diversity. The phylogenetic spectrum combined species associated with the outside environment, taxa closely related to potential human pathogens, and beneficials as well as included 7 phyla and 76 genera. In addition, Propionibacterium spp., Pseudomonas spp., and Burkholderia spp. were identified as important sources of infections. Despite significantly different bacterial area profiles for floors, medical devices, and workplaces, similarities by network analyses and strains with identical molecular fingerprints were detected. This information will allow for new assessment of public health risks in ICUs, help create new sanitation protocols, and further our understanding of the development of hospital-acquired infections.Entities:
Mesh:
Substances:
Year: 2013 PMID: 23475210 PMCID: PMC3593336 DOI: 10.1038/srep01413
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1Cartoon illustration showing each sampling site of the intensive care unit (ICU).
Origin of the single samples is explained in Table 1.
Figure 2Schematic drawing showing the detected bacterial genera found in the three different areas (floor, devices and workplaces) in the intensive care unit (ICU).
Overlaps between the facilities are indicated by the arrangement of the circles.
Figure 3The bacterial communities of the floor environment (A), medical devices (B) and workplaces (C).
Relative clone composition of genera was determined by pyrosequencing of 16S rRNA from metagenomic DNA extracted from the intensive care unit. The identification of the closest strain based on 16S rRNA sequence similarity was achieved using the web server SnoWMAn 1.11 (http://snowman.genome.tugraz.at). Phylogenetic groups accounting for 1% of all quality sequences are summarized in the artificial group Other. Multi-colored charts at the legend are shown for each genus and sample correspondingly.
Locations and characteristics of sampling points for cultivation-independent and -dependent methods of the intensive care unit (ICU)
| (A) Samples for cultivation-independent analysis | ||||
|---|---|---|---|---|
| Sampling location | Description | Sampling tool | Sample ID | MID |
| Entrance visitors | Floor | BiSKit | F1 | MID32 |
| Procedure room | Floor | BiSKit | F2 | MID33 |
| Isolation room | Floor | BiSKit | F3 | MID34 |
| Patient room - Time 0 | Floor | BiSKit | F4 | MID35 |
| Patient room - 24 h after cleaning | Floor | BiSKit | F5 | MID36 |
| Respirator - Patient room | Device | Nylon flocked swab | D6 | MID45 |
| Respirator - Procedure room | Device | Nylon flocked swab | D7 | MID46 |
| Respirator - Isolation room | Device | Nylon flocked swab | D8 | MID47 |
| Perfusor - Patient room | Device | Nylon flocked swab | D9 | MID48 |
| Perfusor - Procedure room | Device | Nylon flocked swab | D10 | MID49 |
| Perfusor - Isolation room | Device | Nylon flocked swab | D11 | MID50 |
| Blood gas analyzer | Device | Nylon flocked swab | D12 | MID51 |
| Docking station | Device | Nylon flocked swab | D13 | MID53 |
| Ultrasound device | Device | Nylon flocked swab | D14 | MID41 |
| Defibrillator | Device | Nylon flocked swab | D15 | MID40 |
| Endoscope tip | Device | Nylon flocked swab | D16 | MID52 |
| Workplace - Patient room | Working Surface | BiSKit | W17 | MID37 |
| Workplace - Isolation room | Working Surface | BiSKit | W18 | MID54 |
| Workplace - Bandage trolley | Working Surface | BiSKit | W19 | MID38 |
| Bandage trolley - Grasp | Working Surface | Nylon flocked swab | W20 | MID42 |
| Bandage trolley in isolation room | Working Surface | Nylon flocked swab | W21 | MID43 |
| Keyboard - Central nurse station | Working Surface | Nylon flocked swab | W22 | MID55 |
| Keyboard - Doctors room | Working Surface | Nylon flocked swab | W23 | MID56 |
| Staff Lounge | Working Surface | Nylon flocked swab | W24 | MID39 |
| Workplace - Patient room | Working Surface | Contact test | WS 42 | 2 |
| Workplace - Bandage trolley | Working Surface | Contact test | WB 43 | 21 |
| Respirator - Patient room | Device | Contact test | RS 44 | 15 |
| Perfusor - Patient room | Device | Contact test | PS 45 | 210 |
| Keyboard - Central nurse station | Device | Contact test | KO 46 | 512 |
| Keyboard - Doctors room | Device | Contact test | KD 47 | 48 |
| Blood gas analyzer | Device | Contact test | BG 48 | 72 |
| Docking station | Device | Contact test | DS 49 | 87 |
| Ultrasound device - Control panel | Device | Contact test | UU 50 | 6 |
| Ultrasound device - Probe | Device | Contact test | UU 51 | 25 |
Abbreviations: BiSKit, Biological Sampling Kit; MID, Multiplex Identifier Sequence; CFU, Colony Forming Units per sample.
1,2 Respective sample areas were 1 m2 for BiSKits, 25 cm2 for Nylon flocked swabs and for 10 cm2 contact tests.
Species richness estimates obtained at 3%, 5% and 20% genetic dissimilarity from pyrosequencing of 16S rRNA from metagenomic DNA extracted from the floor, medical devices and workplaces
| Shannon index (H′) | Rarefaction | Chao1 | Coverage (%) | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dissimilarity cut-off | 3% | 5% | 20% | 3% | 5% | 20% | 3% | 5% | 20% | 3% | 5% | 20% |
| Entrance visitors | 4.09 | 3.64 | 2.24 | 778.46 | 553.66 | 97.97 | 1713.009 | 1035.833 | 121.100 | 45.5 | 53.5 | 80.9 |
| Procedure room | 3.03 | 2.73 | 2.08 | 198.9 | 129.94 | 17 | 361.303 | 223.261 | 17.000 | 55.1 | 58.2 | 100.0 |
| Isolation room | 2.29 | 2.04 | 1.24 | 347.8 | 250.87 | 34 | 778.055 | 525.405 | 35.500 | 44.7 | 47.8 | 95.8 |
| Sick chamber - Time 0 | 3.54 | 3.02 | 2.23 | 571.68 | 412.8 | 56.99 | 1234.414 | 740.217 | 63.429 | 46.3 | 55.8 | 89.9 |
| Sick chamber - 24 h after cleaning | 2.74 | 2.40 | 1.60 | 200.9 | 131.94 | 24 | 354.270 | 222.048 | 26.000 | 56.7 | 59.4 | 92.3 |
| Respirator - Patient room | 2.86 | 2.51 | 1.80 | 163.94 | 98.97 | 13 | 210.923 | 117.913 | 13.000 | 77.8 | 84.0 | 100.0 |
| Respirator - Procedure room | 2.81 | 2.60 | 1.95 | 181.92 | 95.98 | 12 | 294.857 | 116.313 | 12.000 | 61.7 | 82.5 | 100.0 |
| Respirator - Isolation room | 3.07 | 2.70 | 2.05 | 167.93 | 94.97 | 14 | 233.022 | 122.750 | 17.000 | 72.1 | 77.4 | 82.4 |
| Perfusor - Patient room | 2.97 | 2.45 | 1.58 | 153.94 | 90.96 | 11 | 247.261 | 203.875 | 11.000 | 62.3 | 44.6 | 100.0 |
| Perfusor - Procedure room | 3.44 | 3.13 | 2.14 | 224.89 | 143.94 | 15 | 399.000 | 230.667 | 15.000 | 56.4 | 62.4 | 100.0 |
| Perfusor - Isolation room | 2.89 | 2.59 | 1.90 | 147.93 | 80.98 | 10 | 247.400 | 99.056 | 10.000 | 59.8 | 81.8 | 100.0 |
| Blood gas analyzer | 2.90 | 2.58 | 1.82 | 147.94 | 84.97 | 10 | 226.792 | 109.800 | 10.000 | 65.3 | 77.4 | 100.0 |
| Docking station | 3.10 | 2.81 | 2.06 | 242.9 | 160.95 | 28 | 397.895 | 220.111 | 29.500 | 61.1 | 73.1 | 94.9 |
| Ultrasound device | 3.11 | 2.90 | 1.90 | 181.92 | 119.96 | 16 | 297.161 | 154.440 | 16.000 | 61.2 | 77.7 | 100.0 |
| Defibrillator | 2.78 | 2.38 | 1.88 | 154.93 | 102.97 | 14 | 224.000 | 121.207 | 14.000 | 69.2 | 85.0 | 100.0 |
| Endoscope tip | 3.00 | 2.66 | 1.85 | 173.92 | 100.95 | 16 | 356.045 | 181.571 | 17.500 | 48.9 | 55.6 | 91.4 |
| Workplace - Patient room | 4.11 | 3.73 | 2.44 | 425.83 | 301.91 | 42 | 653.586 | 386.875 | 42.250 | 65.2 | 78.1 | 99.4 |
| Workplace - Isolation room | 3.05 | 2.77 | 1.75 | 169.93 | 101.97 | 14 | 266.871 | 146.400 | 14.000 | 63.7 | 69.7 | 100.0 |
| Workplace - Bandage trolley | 4.64 | 4.24 | 2.82 | 572.74 | 404.85 | 52.99 | 1073.039 | 579.690 | 63.500 | 53.4 | 69.9 | 83.5 |
| Bandage trolley - Grasp | 2.94 | 2.55 | 1.61 | 136.95 | 67.98 | 9 | 192.682 | 83.833 | 9.000 | 71.1 | 81.1 | 100.0 |
| Bandage vehicle isoltion room | 3.57 | 3.29 | 2.32 | 295.86 | 193.93 | 27 | 539.886 | 299.556 | 27.000 | 54.8 | 64.8 | 100.0 |
| Keyboard - Central nurse station | 3.34 | 3.04 | 1.76 | 181.94 | 111.97 | 15 | 235.318 | 137.143 | 15.000 | 77.3 | 81.7 | 100.0 |
| Keyboard - Doctors room | 3.45 | 3.14 | 2.03 | 197.92 | 118.96 | 16 | 306.243 | 153.167 | 16.000 | 64.7 | 77.7 | 100.0 |
| Staff Lounge | 2.60 | 2.26 | 1.50 | 141.95 | 74.98 | 7 | 224.650 | 117.857 | 7.000 | 63.2 | 63.6 | 100.0 |
aa higher number indicates more diversity.
bthe results from the rarefaction analyses are also depicted in Figure 4.
cnonparametric richness estimator based on the distribution of singletons and doubletons.
dClusters were obtained with 3%, 5% and 20% dissimilarity cut-offs which correspond to the taxonomic level of species, genera and phyla.
Figure 4Bacterial communities associated with different areas of the intensive care unit by principal coordinate analysis (PCoA).
Two- (A) and three-dimensional (B) PCoA plot based on the weighted UniFrac distance matrix. Percentage of the diversity distribution explained by each axes is indicated on the figure. Samples associated with the floor (green triangle), medical devices (red rectangle) and workplaces (blue points) are shown as single points.
Figure 5Profile clustering Cytoscape network visualize the 40 most abundant OTUs across the floor (green), medical devices (red) and workplaces (blue) of the ICU.
Node sizes correspond to the mean relative abundance between the three sampling areas where two (three) sampling groups feature the same relative abundance over the respective samples and the full nodes are subdivided into two (three) areas. A comparative node (grey) indicates the size of a node that would represent 100 reads in a sample.
Cultivation dependent ARDRA (amplified ribosomal RNA gene restriction analysis; cutoff level of 85%) and BOX analysis (cutoff level of 85%) of 130 isolates
| ARDRA group | BOX group | Sampling site | Sample-ID | Closest NCBI database match | Accession No. | Max. identity |
|---|---|---|---|---|---|---|
| 1 | 1 | KD | 47/8 | NR_037113.1 | 99% | |
| 2 | 1 | DS | 49/11 | NR_037038.1 | 99% | |
| 3 | 1 | WB | 43/24 | NR_028857.1 | 99% | |
| 4 | 1 | DS | 49/16 | NR_041323.1 | 99% | |
| 4 | 2 | DS | 49/9 | NR_041323.1 | 99% | |
| 4 | 3 | DS | 49/1 | NR_041323.1 | 99% | |
| 4 | 4 | KD | 47/15 | NR_024665.1 | 100% | |
| 4 | 4 | DS | 49/13 | |||
| 4 | 5 | UU | 51/12 | NR_036904.1 | 99% | |
| 4 | 5 | UU | 51/9 | |||
| 4 | 5 | KD | 47/12 | |||
| 4 | 5 | UU | 51/2 | |||
| 4 | 5 | KD | 47/10 | |||
| 4 | 5 | UU | 51/10 | |||
| 4 | 5 | KD | 47/16 | |||
| 4 | 5 | KD | 47/5 | |||
| 4 | 5 | UU | 51/17 | |||
| 4 | 5 | DS | 49/14 | |||
| 4 | 5 | UU | 51/18 | |||
| 4 | 5 | UU | 50/1 | |||
| 4 | 5 | UU | 51/13 | |||
| 4 | 5 | DS | 49/7 | |||
| 4 | 5 | UU | 51/4 | |||
| 4 | 5 | UU | 51/14 | NR_036904.1 | 99% | |
| 4 | 5 | KD | 47/14 | |||
| 4 | 6 | KD | 47/17 | NR_041323.1 | 99% | |
| 4 | 7 | KD | 47/13 | NR_024665.1 | 99% | |
| 4 | 8 | DS | 49/10 | NR_036904.1 | 100% | |
| 4 | 9 | DS | 49/6 | NR_025922.1 | 100% | |
| 4 | 10 | DS | 49/4 | |||
| 4 | 10 | UU | 50/3 | |||
| 4 | 10 | UU | 50/2 | |||
| 4 | 10 | UU | 50/5 | NR_041323.1 | 98% | |
| 4 | 10 | DS | 49/15 | |||
| 4 | 11 | DS | 49/3 | NR_024665.1 | 100% | |
| 4 | 12 | DS | 49/2 | NR_036902.1 | 100% | |
| 4 | 13 | DS | 49/8 | NR_036904.1 | 100% | |
| 4 | 14 | UU | 51/6 | NR_036904.1 | 100% | |
| 4 | 15 | UU | 50/4 | NR_041323.1 | 98% | |
| 5 | 1 | KD | 47/11 | NR_036904.1 | 99% | |
| 6 | 1 | BG | 48/18 | NR_036904.1 | 100% | |
| 7 | 1 | KO | 46/17 | NR_025922.1 | 100% | |
| 7 | 2 | KO | 46/21 | NR_036904.1 | 100% | |
| 7 | 3 | KO | 46/18 | |||
| 7 | 3 | KO | 46/19 | NR_036956.1 | 99% | |
| 8 | 1 | KO | 46/20 | |||
| 8 | 1 | KO | 46/22 | NR_036904.1 | 99% | |
| 9 | 1 | KD | 47/1 | NR_036904.1 | 98% | |
| 9 | 1 | BG | 48/5 | |||
| 9 | 1 | BG | 48/1 | |||
| 9 | 2 | BG | 48/10 | NR_036904.1 | 100% | |
| 9 | 3 | BG | 48/7 | NR_036904.1 | 100% | |
| 9 | 4 | BG | 48/6 | NR_036955.1 | 99% | |
| 9 | 5 | BG | 48/11 | NR_041323.1 | 99% | |
| 9 | 5 | BG | 48/12 | |||
| 9 | 5 | BG | 48/9 | |||
| 9 | 5 | BG | 48/13 | |||
| 9 | 6 | BG | 48/3 | NR_024668.1 | 100% | |
| 10 | 1 | BG | 48/14 | NR_041323.1 | 99% | |
| 10 | 2 | BG | 48/15 | NR_041323.1 | 99% | |
| 11 | 1 | BG | 48/2 | |||
| 11 | 1 | BG | 48/8 | NR_025011.1 | 100% | |
| 12 | 1 | UU | 51/16 | NR_043268.1 | 99% | |
| 12 | 1 | UU | 51/3 | NR_043268.1 | 99% | |
| 13 | 1 | KO | 46/23 | NR_042272.1 | 99% | |
| 14 | 1 | UU | 51/15 | NR_036897.1 | 99% | |
| 14 | 2 | UU | 51/7 | NR_036897.1 | 99% | |
| 15 | 1 | KD | 47/3 | NR_026198.1 | 98% | |
| 16 | 1 | UU | 51/8 | NR_042286.1 | 96% | |
| 17 | 1 | WS | 42/2 | NR_036956.1 | 99% | |
| 17 | 2 | RS | 44/11 | NR_036955.1 | 99% | |
| 17 | 3 | KO | 46/7 | NR_025922.1 | 100% | |
| 17 | 4 | WB | 43/18 | |||
| 17 | 4 | PS | 45/5 | |||
| 17 | 4 | PS | 45/8 | |||
| 17 | 4 | WB | 43/13 | NR_041323.1 | 99% | |
| 17 | 5 | WB | 43/17 | |||
| 17 | 5 | KO | 46/16 | |||
| 17 | 5 | WB | 43/2 | |||
| 17 | 5 | KO | 46/3 | |||
| 17 | 5 | KO | 46/15 | |||
| 17 | 5 | RS | 44/3 | NR_036904.1 | 100% | |
| 17 | 6 | KO | 46/6 | NR_036904.1 | 99% | |
| 17 | 7 | PS | 45/6 | NR_036904.1 | 100% | |
| 17 | 8 | PS | 45/7 | NR_041323.1 | 99% | |
| 17 | 9 | PS | 45/3 | NR_041323.1 | 98% | |
| 17 | 10 | KO | 46/13 | |||
| 17 | 10 | KO | 46/2 | |||
| 17 | 10 | KO | 46/11 | NR_041323.1 | 98% | |
| 17 | 11 | KO | 46/14 | NR_024668.1 | 100% | |
| 17 | 12 | RS | 44/18 | |||
| 17 | 12 | KO | 46/10 | |||
| 17 | 12 | RS | 44/12 | |||
| 17 | 12 | RS | 44/2 | |||
| 17 | 12 | PS | 45/11 | |||
| 17 | 12 | PS | 45/4 | |||
| 17 | 12 | WS | 42/1 | |||
| 17 | 12 | RS | 44/1 | NR_036956.1 | 99% | |
| 17 | 12 | WB | 43/12 | |||
| 17 | 12 | WB | 43/1 | |||
| 17 | 13 | KO | 46/9 | NR_025922.1 | 99% | |
| 18 | 1 | WB | 43/10 | NR_036904.1 | 100% | |
| 18 | 2 | RS | 44/17 | NR_036904.1 | 97% | |
| 19 | 1 | RS | 44/10 | NR_024665.1 | 99% | |
| 20 | 1 | WB | 43/4 | |||
| 20 | 1 | WB | 43/5 | NR_044871.1 | 99% | |
| 21 | 1 | WB | 43/23 | NR_042726.1 | 99% | |
| 21 | 2 | WB | 43/7 | NR_042726.1 | 99% | |
| 21 | 3 | WB | 43/16 | GU339271.1 | 79% | |
| 22 | 1 | RS | 44/14 | |||
| 22 | 1 | RS | 44/4 | NR_042639.1 | 100% | |
| 22 | 2 | PS | 45/10 | NR_042136.1 | 100% | |
| 23 | 1 | BG | 48/17 | NR_041323.1 | 99% | |
| 24 | 1 | RS | 44/16 | |||
| 24 | 1 | RS | 44/5 | NR_037113.1 | 97% | |
| 24 | 2 | WB | 43/6 | NR_037113.1 | 92% | |
| 24 | 3 | WB | 43/3 | NR_037113.1 | 99% | |
| 25 | 1 | RS | 44/8 | NR_026198.1 | 100% | |
| 26 | 1 | DS | 49/5 | NR_037113.1 | 98% | |
| 26 | 2 | UU | 51/1 | NR_037113.1 | 97% | |
| 27 | 1 | KD | 47/4 | NR_026451.1 | 98% | |
| 28 | 1 | BG | 48/16 | NR_025285.1 | 99% | |
| 29 | 1 | BG | 48/4 | NR_025285.1 | 99% | |
| 30 | 1 | WB | 43/9 | NR_025285.1 | 99% | |
| 31 | 1 | KD | 47/7 | NR_037113.1 | 99% | |
| 32 | 1 | RS | 44/9 | NR_025285.1 | 99% | |
| 33 | 1 | KD | 47/9 | NR_037113.1 | 99% | |
| 34 | 1 | RS | 44/13 | NR_026451.1 | 99% | |
| 35 | 1 | PS | 45/9 | NR_043443.1 | 99% | |
| 36 | 1 | KO | 46/4 | NR_037113.1 | 99% |
Figure 6BOX PCR fingerprints of genetically very similar Staphylococcus species isolated from nearly all sampling sites.
The similarity of BOX patterns between them was more than 80%.