A four-pixel matched collimator for high-sensitivity SPECT imaging.

Atsuro Suzuki1, Wataru Takeuchi, Takafumi Ishitsu, Katsutoshi Tsuchiya, Yuichiro Ueno, Keiji Kobashi.   

Abstract

We propose a wide aperture parallel-hole collimator that we call a 4-pixel matched collimator (4-PMC) for high-sensitivity SPECT imaging. The hole size of the 4-PMC is matched to four detector pixels; that is, there are four (2 × 2) pixels per collimator hole. By contrast, a 1-pixel matched collimator (1-PMC) is defined as a collimator whose hole size is matched to one detector pixel. We evaluated four types of collimator (high-resolution collimator versions and high-sensitivity collimator versions of both 4-PMC and 1-PMC) by simulation. SPECT images of a cylindrical phantom with cold spots in the noise-free condition demonstrated that the 4-PMC provided a higher-contrast image than the 1-PMC for the same collimator version. In addition, SPECT images at the noise level corresponding to a human cerebral blood flow study suggested that the high-sensitivity version of the 4-PMC provided the highest contrast image among the four collimator types. In conclusion, the high-sensitivity SPECT system using the 4-PMC can improve the trade-off between spatial resolution and sensitivity and will consequently provide improved image contrast for clinical studies of the human brain compared with the SPECT system using the 1-PMC.

Entities:  

Mesh:

Year:  2013        PMID: 23475193     DOI: 10.1088/0031-9155/58/7/2199

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  An energy-optimized collimator design for a CZT-based SPECT camera.

Authors:  Fenghua Weng; Srijeeta Bagchi; Yunlong Zan; Qiu Huang; Youngho Seo
Journal:  Nucl Instrum Methods Phys Res A       Date:  2016-01-11       Impact factor: 1.455

2.  Evaluation of a variable-aperture full-ring SPECT system using large-area pixelated CZT modules: A simulation study for brain SPECT applications.

Authors:  Yoonsuk Huh; Jaewon Yang; Odera U Dim; Yonggang Cui; Weijie Tao; Qiu Huang; Grant T Gullberg; Youngho Seo
Journal:  Med Phys       Date:  2021-03-30       Impact factor: 4.071

3.  Simultaneous Tc-99m and I-123 dual-radionuclide imaging with a solid-state detector-based brain-SPECT system and energy-based scatter correction.

Authors:  Wataru Takeuchi; Atsuro Suzuki; Tohru Shiga; Naoki Kubo; Yuichi Morimoto; Yuichiro Ueno; Keiji Kobashi; Kikuo Umegaki; Nagara Tamaki
Journal:  EJNMMI Phys       Date:  2016-06-29

4.  Technical Note: Nuclear imaging with an x-ray flat panel detector: A proof-of-concept study.

Authors:  Martijn M A Dietze; Wilco J C Koppert; Rob van Rooij; Hugo W A M de Jong
Journal:  Med Phys       Date:  2020-05-08       Impact factor: 4.071

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.