Literature DB >> 23471134

A power-free microfluidic chip for SNP genotyping using graphene oxide and a DNA intercalating dye.

Jing Li1, Yan Huang, Dongfang Wang, Bo Song, Zhenhua Li, Shiping Song, Lihua Wang, Bowei Jiang, Xingchun Zhao, Juan Yan, Rui Liu, Dannong He, Chunhai Fan.   

Abstract

We herein report a power-free microfluidic chip for fluorescent DNA detection with high single-nucleotide polymorphism discrimination, using a DNA intercalator and graphene oxide.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23471134     DOI: 10.1039/c3cc40680f

Source DB:  PubMed          Journal:  Chem Commun (Camb)        ISSN: 1359-7345            Impact factor:   6.222


  6 in total

1.  A robust and versatile signal-on fluorescence sensing strategy based on SYBR Green I dye and graphene oxide.

Authors:  Huazhang Qiu; Namei Wu; Yanjie Zheng; Min Chen; Shaohuang Weng; Yuanzhong Chen; Xinhua Lin
Journal:  Int J Nanomedicine       Date:  2014-12-22

2.  A New Approach To the Diagnosis of Point Mutations in Native DNA Using Graphene Oxide.

Authors:  A A Kuznetsov; N R Maksimova; V S Kaimonov; G N Alexandrov; S A Smagulova
Journal:  Acta Naturae       Date:  2016 Apr-Jun       Impact factor: 1.845

3.  A Microfluidic DNA Sensor Based on Three-Dimensional (3D) Hierarchical MoS₂/Carbon Nanotube Nanocomposites.

Authors:  Dahou Yang; Mahnoush Tayebi; Yinxi Huang; Hui Ying Yang; Ye Ai
Journal:  Sensors (Basel)       Date:  2016-11-14       Impact factor: 3.576

4.  A direct isothermal amplification system adapted for rapid SNP genotyping of multifarious sample types.

Authors:  Xiaonan Liu; Chao Zhang; Mengye Zhao; Kewu Liu; Hang Li; Ningning Li; Linlin Gao; Xuemin Yang; Ting Ma; Juanli Zhu; Wenli Hui; Kai Hua; Yali Cui
Journal:  Biosens Bioelectron       Date:  2018-05-11       Impact factor: 10.618

5.  Detection of Single Nucleotide Polymorphisms by Fluorescence Embedded Dye SYBR Green I Based on Graphene Oxide.

Authors:  Jiaoyun Xia; Tong Xu; Jing Qing; Lihua Wang; Junlong Tang
Journal:  Front Chem       Date:  2021-03-31       Impact factor: 5.221

6.  Super-assembly of integrated gold magnetic assay with loop-mediated isothermal amplification for point-of-care testing.

Authors:  Jianping Liang; Jie Zeng; Xiaojuan Huang; Tengteng Zhu; Yonglong Gong; Chen Dong; Xiangrong Wang; Lingzhi Zhao; Lei Xie; Kang Liang; Qiongxiang Tan; Yali Cui; Biao Kong; Wenli Hui
Journal:  Nano Res       Date:  2022-08-04       Impact factor: 10.269

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.