Air toxicity for primary human-cultured corneal endothelial cells: an in vitro model.

Nikolaos Kopsachilis1, Konstantinos T Tsaousis, Ioannis T Tsinopoulos, Ulrich Welge-Luessen.   

Abstract

PURPOSE: To investigate the possible toxic effect of air exposure for an in vitro model of primary human corneal endothelial cells (HCECs).
METHODS: Primary HCECs were isolated from donor corneal rings and cultivated at 37°C in 5% CO2 and 95% humidified air. Six groups of HCEC cultures were set up, and 4 samples were enclosed in each group: group 1 consisted of samples in which HCECs were exposed to air for 30 minutes. Group 2 consisted of HCECs exposed to air for 1 hour, group 3 for 3 hours, group 4 for 6 hours, group 5 for 12 hours, and group 6 for 24 hours.
RESULTS: Three hours after exposure, the morphology of the cells was still intact; however, a few cells within the monolayer appeared enlarged and exhibited characteristics of more senescent cells. Six hours after exposure to air, the endothelial cells started losing their typical hexagonal morphology and appeared enlarged and compromised. Viability was superior to 95% in groups 1 to 3, whereas for groups 4, 5, and 6 was 71%, 22.4%, and 6.3%, respectively.
CONCLUSION: The present study illustrates that the toxic effect of air exposure for the studied in vitro model of primary human-cultured corneal endothelial cells is not significant for the period of 3 hours, whereas after 6 hours it starts to induce major apoptotic mechanisms, leading to reduced viability until the period of 24 hours where the percentage of living cells is drastically decreased.

Entities:  

Mesh:

Year:  2013        PMID: 23471026     DOI: 10.1097/ICO.0b013e31826895f8.

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  5 in total

1.  Endothelial keratoplasty: is Descemet membrane endothelial keratoplasty the Holy Grail of lamellar surgery? No.

Authors:  M Tsatsos; V S Liarakos; C MacGregor; I Athanasiadis; E T Detorakis; M M Moschos; P Hossain; D F Anderson
Journal:  Eye (Lond)       Date:  2017-04-21       Impact factor: 3.775

2.  Effect of Graft Attachment Status and Intraocular Pressure on Descemet Stripping Automated Endothelial Keratoplasty Outcomes in the Cornea Preservation Time Study.

Authors:  Anthony J Aldave; Mark A Terry; Loretta B Szczotka-Flynn; Wendi Liang; Allison R Ayala; Maureen G Maguire; Robert C O'Brien; Beth Ann Benetz; John E Bokosky; Steven P Dunn; Thomas E Gillette; Kristin M Hammersmith; David R Hardten; Bennie H Jeng; Marc F Jones; Richard L Lindstrom; Kenneth J Maverick; Verinder S Nirankari; Matthew S Oliva; Irving M Raber; Christopher J Rapuano; George O D Rosenwasser; Kevin W Ross; John W Seedor; Neda Shamie; Christopher G Stoeger; Shachar Tauber; Woodford S Van Meter; David D Verdier; Jonathan H Lass
Journal:  Am J Ophthalmol       Date:  2019-03-06       Impact factor: 5.258

3.  Safety of air tamponade versus corneal hydration for sealing clear corneal incisions in cataract surgery.

Authors:  Asimina Mataftsi; Maria Dermenoudi; Artemis Matsou; Argyrios Tzamalis; Periklis Brazitikos; Persefoni Talimtzi; Nikolaos Ziakas; Ioannis T Tsinopoulos
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-01-18       Impact factor: 3.117

4.  Gas-Graft Coverage After DMEK: A Clinically Validated Numeric Study.

Authors:  Jan O Pralits; Mark Alberti; Javier Cabreizo
Journal:  Transl Vis Sci Technol       Date:  2019-11-12       Impact factor: 3.283

Review 5.  Substrates for Expansion of Corneal Endothelial Cells towards Bioengineering of Human Corneal Endothelium.

Authors:  Jesintha Navaratnam; Tor P Utheim; Vinagolu K Rajasekhar; Aboulghassem Shahdadfar
Journal:  J Funct Biomater       Date:  2015-09-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.