Literature DB >> 23468437

Effect of physician training on the X-ray dose delivered during coronary angioplasty.

José Ramón Azpiri-López1, José Luis Assad-Morell, José Gerardo González-González, Guillermo Elizondo-Riojas, Adrián Dávila-Bortoni, Rodrigo García-Martínez, Ramón Treviño-Frutos.   

Abstract

OBJECTIVE: To assess whether physician training helps decrease the amount of radiation delivered to patients undergoing coronary angioplasty with stent placement.
BACKGROUND: Coronary angioplasty exposes patients to high doses of ionizing radiation, possibly related to equipment misuse or inappropriate training.
METHODS: Reference point air kerma (K(a,r)) and kerma area product (P(KA)) were prospectively registered during a period of 6 months in patients undergoing coronary angiography and angioplasty with stent ad hoc. All interventionalists were then invited to an informative conference on appropriate use of radiation and changes in x-ray delivery settings. Data were recorded during the following 6 months and then compared for the whole group and for those who did or did not attend the conference.
RESULTS: K(a,r) decreased from 5.44 ± 0.3 Gy (n = 106) to 3.39 ± 0.22 Gy (n = 112); P<.0001 and P(KA) decreased from 365.4 ± 21.1 Gy·cm(-2); to 233.7 ± 13.1 Gy·cm(-2); P<.0001. During the first 6 months, there were no differences in radiation emitted among physicians; however, during the second half of the study, there was a 34% difference in K(a,r) between those that attended the conference and those who did not (2.78 ± 0.23 Gy vs 4.18 ± 0.37 Gy; P=.002), regardless of the fact that both groups lowered radiation emission settings.
CONCLUSION: Changes in x-ray parameters profoundly reduce the amount of radiation delivered to patients, a situation that was more evident in those who attended an informative conference. It is important to educate cardiologists in the appropriate use of modern x-ray equipment.

Entities:  

Mesh:

Year:  2013        PMID: 23468437

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  5 in total

1.  ECG-gated coronary angiography enables submillisievert imaging in invasive cardiology.

Authors:  E Kuon; S B Felix; K Weitmann; I Büchner; A Hummel; M Dörr; T Reffelmann; A Riad; M C Busch; K Empen
Journal:  Herz       Date:  2014-10-04       Impact factor: 1.443

2.  Reducing radiation exposure during invasive coronary angiography and percutaneous coronary interventions implementing a simple four-step protocol.

Authors:  Moritz Seiffert; Francisco Ojeda; Kai Müllerleile; Elvin Zengin; Christoph Sinning; Christoph Waldeyer; Edith Lubos; Ulrich Schäfer; Karsten Sydow; Stefan Blankenberg; Dirk Westermann
Journal:  Clin Res Cardiol       Date:  2015-01-22       Impact factor: 5.460

Review 3.  Reducing radiation in chronic total occlusion percutaneous coronary interventions.

Authors:  Antonis N Pavlidis; Daniel A Jones; Alex Sirker; Anthony Mathur; Elliot J Smith
Journal:  Curr Cardiol Rev       Date:  2016

4.  Establishing a diagnostic reference level of radiation dose in coronary angiography and intervention: A prospective evaluation.

Authors:  Vikas Kataria; Ishita Yaduvanshi; Gautam Singal; Mohan Nair
Journal:  Indian Heart J       Date:  2021-09-21

5.  Radiation dose in coronary angiography and intervention: initial results from the establishment of a multi-centre diagnostic reference level in Queensland public hospitals.

Authors:  James A Crowhurst; Mark Whitby; David Thiele; Toni Halligan; Adam Westerink; Suzanne Crown; Jillian Milne
Journal:  J Med Radiat Sci       Date:  2014-08-04
  5 in total