Literature DB >> 23463256

Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator.

Hyun-Joo Lee1, Chang-Wug Oh, Jong-Keon Oh, Theerachai Apivatthakakul, Joon-Woo Kim, Jong-Pil Yoon, Dong-Joo Lee, Jae-Wook Jung.   

Abstract

BACKGROUND: Minimally invasive plate osteosynthesis (MIPO) has become a popular option for treatment of humeral shaft fractures. However, indirect reduction might risk unpromising results, with mal-alignment/mal-union or nonunion. The purpose of this study was to describe a reproducible MIPO technique that used an external fixator during the procedure as a tool for reduction and maintenance, and to assess the outcomes in patients with humeral shaft fracture.
METHODS: Of 31 consecutive cases of humeral shaft fracture in 30 patients, 29 were included in this study. There were seven simple (type A) and 22 comminuted (type B or C) fractures. After the insertion of one Schanz pin on each proximal and distal humerus, a provisional reduction was achieved by connecting the pins with a monolateral external fixator. The MIPO procedure was then performed over the anterior aspect of the humerus. To evaluate the efficacy of the provisional reduction by external fixator, coronal and sagittal alignments were assessed. We also assessed bony and functional results, including complications, from this technique.
RESULTS: There was no case of mal-union >10°, and mean angulation was 1.3° (range 0°-9°) in the coronal plane and 1.2° (range 0°-8°) in the sagittal plane. Twenty-eight of 29 fractures were united, including three delayed unions, with a mean union time of 19.1 weeks (range 12.3-38.4 weeks) and a mean follow-up of 20.8 months (range 13.5-31.0 months). There was one hypertrophic nonunion that healed after fixing with two additional screws. Except one patient with associated injury in the elbow, all patients recovered to pre-injury joint motion. There were two cases of postoperative radial nerve palsy that both recovered completely. We attributed them to manipulation, and not to the Schanz pins or plate fixation.
CONCLUSIONS: Surgical treatment of humeral shaft fractures with external fixator-assisted reduction and MIPO resulted in excellent reductions and high union rates.

Entities:  

Mesh:

Year:  2013        PMID: 23463256     DOI: 10.1007/s00402-013-1708-7

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  9 in total

1.  The treatment of distal third humeral diaphyseal fractures: Is there still a place for the external fixation?

Authors:  N Tartaglia; G Vicenti; M Carrozzo; A Abate; F Rifino; G Picca; G Solarino; B Moretti
Journal:  Musculoskelet Surg       Date:  2016-11-30

2.  Fixator-assisted Technique Enables Less Invasive Plate Osteosynthesis in Medial Opening-wedge High Tibial Osteotomy: A Novel Technique.

Authors:  Dong Hoon Lee; Keun Jung Ryu; Jae Hwa Kim; Hae Hwa Kim; Sahyun Soung; Soowan Shin
Journal:  Clin Orthop Relat Res       Date:  2015-10       Impact factor: 4.176

3.   Time until union in absolute vs. relative stability MIPO plating in simple humeral shaft fractures.

Authors:  Ignacio Rellán; Gerardo Luis Gallucci; Agustin Guillermo Donndorff; Pablo De Carli; Ezequiel Ernesto Zaidenberg; Marc Joseph Richard; Jorge Guillermo Boretto
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-03-29

4.  Dual plating for fixation of humeral shaft fractures: A mechanical comparison of various combinations of plate lengths.

Authors:  Ahmet Karakasli; Onur Basci; Fatih Ertem; Eyad Sekik; Hasan Havitcioglu
Journal:  Acta Orthop Traumatol Turc       Date:  2016-07-29       Impact factor: 1.511

5.  Lateral Subcutaneous Locking Compression Plate and Small Incision Reduction for Distal-third Diaphyseal Humerus Fractures.

Authors:  Hong Chang; Zi-Long Yao; Yi-Long Hou; Yang Cao; Xin-Hui Guo; Guan-Jun Li; Bin Yu
Journal:  Orthop Surg       Date:  2018-08       Impact factor: 2.071

6.  The risk of iatrogenic radial nerve and/or profunda brachii artery injury in anterolateral humeral plating using a 4.5 mm narrow DCP: A cadaveric study.

Authors:  Chaiwat Chuaychoosakoon; Supatat Chirattikalwong; Watit Wuttimanop; Tanarat Boonriong; Wachiraphan Parinyakhup; Sitthiphong Suwannaphisit
Journal:  PLoS One       Date:  2021-11-30       Impact factor: 3.240

7.  New precontoured long locking plate for proximal metadiaphyseal fractures of the humerus: a cadaveric study for its use with the minimally invasive technique.

Authors:  Max Ekdahl; Cristián Dominguez; Miguel Pinedo; Sebastián López; Vicente Gutiérrez
Journal:  JSES Int       Date:  2021-02-24

8.  Biomechanical Study of the Fixation Strength of Anteromedial Plating for Humeral Shaft Fractures.

Authors:  Yin-Feng Zheng; Jun-Lin Zhou; Xiao-Hong Wang; Lei Shan; Yang Liu
Journal:  Chin Med J (Engl)       Date:  2016-08-05       Impact factor: 2.628

9.  Geometrical analysis for assessing torsional alignment of humerus.

Authors:  Yo-Lun Chu; Cheng-Kuang Chen; Yu-Chia Liu; Tung-Wu Lu; Chen-Kun Liaw
Journal:  BMC Musculoskelet Disord       Date:  2020-02-10       Impact factor: 2.362

  9 in total