Literature DB >> 23462745

Ocular rigidity, ocular pulse amplitude, and pulsatile ocular blood flow: the effect of axial length.

Anna I Dastiridou1, Harilaos Ginis, Miltiadis Tsilimbaris, Nikos Karyotakis, Efstathios Detorakis, Charalambos Siganos, Pierros Cholevas, Evangelia E Tsironi, Ioannis G Pallikaris.   

Abstract

PURPOSE: Previous studies have shown a negative correlation between axial length (AL) and pulsatile ocular blood flow (POBF). This relation has been questioned because of the possible confounding effect of ocular volume on ocular rigidity (OR). The purpose of this study was to investigate the relation between AL, as a surrogate parameter for ocular volume, and OR, ocular pulse amplitude (OPA), and POBF.
METHODS: Eighty-eight cataract patients were enrolled in this study. A computer-controlled device comprising a microdosimetric pump and a pressure sensor was used intraoperatively. The system was connected to the anterior chamber and used to raise the intraocular pressure (IOP) from 15 to 40 mm Hg, by infusing the eye with a saline solution. After each infusion step, the IOP was continuously recorded for 2 seconds. Blood pressure and pulse rate were measured during the procedure. The OR coefficient was calculated from the pressure volume data. OPA and POBF were measured from pressure recordings.
RESULTS: Median AL was 23.69 (interquartile range 3.53) mm. OR coefficient was 0.0218 (0.0053) μL(-1). A negative correlation between the OR coefficient and AL (ρ = -0.641, P < 0.001) was documented. Increasing AL was associated with decreased OPA (ρ = -0.637, P < 0.001 and ρ = -0.690, P < 0.001) and POBF (ρ = -0.207, P = 0.053 and ρ = -0.238, P = 0.028) at baseline and elevated IOP, respectively.
CONCLUSIONS: Based on manometric data, increasing AL is associated with decreased OR, OPA, and POBF. These results suggest decreased pulsatility in high myopia and may have implications on ocular pulse studies and the pathophysiology of myopia.

Entities:  

Mesh:

Year:  2013        PMID: 23462745     DOI: 10.1167/iovs.12-11576

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  15 in total

1.  Non-invasive measurement of choroidal volume change and ocular rigidity through automated segmentation of high-speed OCT imaging.

Authors:  L Beaton; J Mazzaferri; F Lalonde; M Hidalgo-Aguirre; D Descovich; M R Lesk; S Costantino
Journal:  Biomed Opt Express       Date:  2015-04-13       Impact factor: 3.732

2.  The Effects of Netarsudil Ophthalmic Solution on Aqueous Humor Dynamics in a Randomized Study in Humans.

Authors:  Arash Kazemi; Jay W McLaren; Casey C Kopczynski; Theresa G Heah; Gary D Novack; Arthur J Sit
Journal:  J Ocul Pharmacol Ther       Date:  2018-02-22       Impact factor: 2.671

3.  The ocular pulse decreases aqueous humor outflow resistance by stimulating nitric oxide production.

Authors:  Michael Madekurozwa; W Daniel Stamer; Ester Reina-Torres; Joseph M Sherwood; Darryl R Overby
Journal:  Am J Physiol Cell Physiol       Date:  2021-01-13       Impact factor: 4.249

4.  Ocular rigidity and outflow facility in nonproliferative diabetic retinopathy.

Authors:  Theonitsa Panagiotoglou; Miltiadis Tsilimbaris; Harilaos Ginis; Nikos Karyotakis; Vaggelis Georgiou; Pavlos Koutentakis; Ioannis Pallikaris
Journal:  J Diabetes Res       Date:  2015-04-14       Impact factor: 4.011

5.  Effect of Axial Eye Length on Retinal Vessel Parameters in 6 to 12-Year-Old Malay Girls.

Authors:  Evelyn Li Min Tai; Ling-Jun Li; Wan Hitam Wan-Hazabbah; Tien-Yin Wong; Ismail Shatriah
Journal:  PLoS One       Date:  2017-01-20       Impact factor: 3.240

6.  Investigation of causes of sex-related differences in ocular blood flow in healthy eyes determined by laser speckle flowgraphy.

Authors:  Takeshi Iwase; Kentaro Yamamoto; Kosei Yanagida; Eimei Ra; Yasuki Ito; Kenta Murotani; Hiroko Terasaki
Journal:  Sci Rep       Date:  2017-10-24       Impact factor: 4.379

7.  Relationship Between the Parameters of Corneal and Fundus Pulse Signals Acquired With a Combined Ultrasound and Laser Interferometry Technique.

Authors:  Monika E Danielewska; Alina Messner; René M Werkmeister; Michał M Placek; Valentin Aranha Dos Santos; Marek Rękas; Leopold Schmetterer
Journal:  Transl Vis Sci Technol       Date:  2019-08-01       Impact factor: 3.283

8.  Non-invasive Clinical Measurement of Ocular Rigidity and Comparison to Biomechanical and Morphological Parameters in Glaucomatous and Healthy Subjects.

Authors:  Yanhui Ma; Sayoko E Moroi; Cynthia J Roberts
Journal:  Front Med (Lausanne)       Date:  2021-07-05

9.  Comparison of Corneal Wave Speed and Ocular Rigidity in Normal and Glaucomatous Eyes.

Authors:  Arash Kazemi; Boran Zhou; Xiaoming Zhang; Arthur J Sit
Journal:  J Glaucoma       Date:  2021-10-01       Impact factor: 2.290

Review 10.  Modern Diagnostic Techniques for the Assessment of Ocular Blood Flow in Myopia: Current State of Knowledge.

Authors:  Ewa Grudzińska; Monika Modrzejewska
Journal:  J Ophthalmol       Date:  2018-01-21       Impact factor: 1.909