Literature DB >> 23458819

Rapid multiexposure in vivo brain imaging system using vertical cavity surface emitting lasers as a light source.

Yaaseen Atchia1, Hart Levy, Suzie Dufour, Ofer Levi.   

Abstract

We demonstrate an imaging technique implementing vertical cavity lasers with extremely low transient times for a greatly simplified realization of a multiexposure laser speckle contrast imaging system. Data from multiexposure laser speckle imaging was observed to more closely agree with absolute velocity measurements using time of flight technique, when compared to long-exposure laser speckle imaging. Furthermore, additional depth information of the vasculature morphology was inferred by accounting for the change in the static scattering from tissue above vessels with respect to the total scattering from blood flow and tissue.

Mesh:

Year:  2013        PMID: 23458819     DOI: 10.1364/AO.52.000C64

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  8 in total

1.  Evaluation of laser speckle contrast imaging as an intrinsic method to monitor blood brain barrier integrity.

Authors:  Suzie Dufour; Yaaseen Atchia; Raanan Gad; Dene Ringuette; Iliya Sigal; Ofer Levi
Journal:  Biomed Opt Express       Date:  2013-08-30       Impact factor: 3.732

2.  Low-cost laser speckle contrast imaging of blood flow using a webcam.

Authors:  Lisa M Richards; S M Shams Kazmi; Janel L Davis; Katherine E Olin; Andrew K Dunn
Journal:  Biomed Opt Express       Date:  2013-09-26       Impact factor: 3.732

3.  Effects of speckle/pixel size ratio on temporal and spatial speckle-contrast analysis of dynamic scattering systems: Implications for measurements of blood-flow dynamics.

Authors:  J C Ramirez-San-Juan; E Mendez-Aguilar; N Salazar-Hermenegildo; A Fuentes-Garcia; R Ramos-Garcia; B Choi
Journal:  Biomed Opt Express       Date:  2013-08-30       Impact factor: 3.732

4.  Reducing misfocus-related motion artefacts in laser speckle contrast imaging.

Authors:  Dene Ringuette; Iliya Sigal; Raanan Gad; Ofer Levi
Journal:  Biomed Opt Express       Date:  2014-12-24       Impact factor: 3.732

5.  Optimization of camera exposure durations for multi-exposure speckle imaging of the microcirculation.

Authors:  S M Shams Kazmi; Satyajit Balial; Andrew K Dunn
Journal:  Biomed Opt Express       Date:  2014-06-10       Impact factor: 3.732

6.  Laser speckle contrast imaging with extended depth of field for in-vivo tissue imaging.

Authors:  Iliya Sigal; Raanan Gad; Antonio M Caravaca-Aguirre; Yaaseen Atchia; Donald B Conkey; Rafael Piestun; Ofer Levi
Journal:  Biomed Opt Express       Date:  2013-12-06       Impact factor: 3.732

7.  Dynamics of isoflurane-induced vasodilation and blood flow of cerebral vasculature revealed by multi-exposure speckle imaging.

Authors:  Colin T Sullender; Lisa M Richards; Fei He; Lan Luan; Andrew K Dunn
Journal:  J Neurosci Methods       Date:  2021-12-01       Impact factor: 2.987

Review 8.  Expanding applications, accuracy, and interpretation of laser speckle contrast imaging of cerebral blood flow.

Authors:  S M Shams Kazmi; Lisa M Richards; Christian J Schrandt; Mitchell A Davis; Andrew K Dunn
Journal:  J Cereb Blood Flow Metab       Date:  2015-05-06       Impact factor: 6.200

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.