Literature DB >> 23457008

A morphometric study of the human fetal heart on post-mortem 3-tesla magnetic resonance imaging.

Inga Sandaite1, Luc De Catte, Philippe Moerman, Marc Gewillig, Luigi Fedele, Jan Deprest, Filip Claus.   

Abstract

OBJECTIVE: To report on the feasibility of assessing cardiac structures on post-mortem 3-tesla MRI (pmMRI) and to provide morphometric data in fetuses without cardiac abnormalities.
METHODS: Retrospective single center study on 3T pmMRI of 39 consecutive fetuses without cardiac abnormalities (13-38 weeks of gestation). Fetal cardiac anatomy was assessed and measurements of cardiac structures were performed on T2-weighted 3D multiplanar reconstructed images. Linear regression analysis was performed to examine changes of cardiac dimensions during gestation.
RESULTS: The four-chamber view of the fetal heart could be obtained and the measurements of cardiac chambers and ventricular walls could be performed in all 39 cases. The aorta and the pulmonary artery were visualized and their diameters were measured in 38 (97.4%) fetuses, ductus arteriosus in 32 (82%). All measurements showed strong linear correlation with gestational age. The relationship of the diameters of the pulmonary artery, aorta, and ductus arteriosus remained constant over pregnancy. All these observations are consistent with what is known from prenatal ultrasound.
CONCLUSIONS: The present study proves the feasibility of visualizing normal cardiac structures on 3-tesla pmMRI in fetuses beyond 14 weeks. We provide morphometric data that may enable diagnostic evaluation of cardiac abnormalities on pmMRI.
© 2013 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2013        PMID: 23457008     DOI: 10.1002/pd.4070

Source DB:  PubMed          Journal:  Prenat Diagn        ISSN: 0197-3851            Impact factor:   3.050


  8 in total

Review 1.  The future of pediatric and perinatal postmortem imaging.

Authors:  Guillaume Gorincour; Laure Sarda-Quarello; Pierre-Eloi Laurent; Alison Brough; Guy N Rutty
Journal:  Pediatr Radiol       Date:  2015-04-01

2.  Post-mortem whole-body magnetic resonance imaging of human fetuses: a comparison of 3-T vs. 1.5-T MR imaging with classical autopsy.

Authors:  Xin Kang; Mieke M Cannie; Owen J Arthurs; Valerie Segers; Catherine Fourneau; Elisa Bevilacqua; Teresa Cos Sanchez; Neil J Sebire; Jacques C Jani
Journal:  Eur Radiol       Date:  2017-01-23       Impact factor: 5.315

Review 3.  Perinatal and paediatric post-mortem magnetic resonance imaging (PMMR): sequences and technique.

Authors:  Wendy Norman; Noorulhuda Jawad; Rod Jones; Andrew M Taylor; Owen J Arthurs
Journal:  Br J Radiol       Date:  2016-03-15       Impact factor: 3.039

Review 4.  Postmortem cardiac imaging in fetuses and children.

Authors:  Andrew M Taylor; Owen J Arthurs; Neil J Sebire
Journal:  Pediatr Radiol       Date:  2015-04-01

5.  Pulmonary hypoplasia associated with congenital heart diseases: a fetal study.

Authors:  Isabelle Ruchonnet-Metrailler; Bettina Bessieres; Damien Bonnet; Shamila Vibhushan; Christophe Delacourt
Journal:  PLoS One       Date:  2014-04-03       Impact factor: 3.240

6.  Novel imaging techniques to study postmortem human fetal anatomy: a systematic review on microfocus-CT and ultra-high-field MRI.

Authors:  Y Dawood; G J Strijkers; J Limpens; R J Oostra; B S de Bakker
Journal:  Eur Radiol       Date:  2019-12-13       Impact factor: 5.315

7.  The Evaluation of the Four-Chamber Cardiac Dissection Method of the Fetal Heart as an Alternative to Conventional Inflow-Outflow Dissection in Small Gestational-Age Fetuses.

Authors:  Camelia Albu; Adelina Staicu; Roxana Popa-Stanilă; Cosmina Bondor; Bogdan Pop; Liviu Chiriac; Dan Gheban; Romeo Micu; Romulus Valeriu Flaviu Turcu; Simion Simon; Doinița Crișan; Florin Stamatian
Journal:  Diagnostics (Basel)       Date:  2022-01-17

Review 8.  Post-mortem MRI as an alternative to non-forensic autopsy in foetuses and children: from research into clinical practice.

Authors:  S Addison; O J Arthurs; S Thayyil
Journal:  Br J Radiol       Date:  2014-04       Impact factor: 3.039

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.