Literature DB >> 2345509

Flow artifact reduction in MRI: a review of the roles of gradient moment nulling and spatial presaturation.

R L Ehman1, J P Felmlee.   

Abstract

In the past, flow artifacts and inconsistent depiction of vascular anatomy have represented significant problems in clinical MRI. These difficulties are now generally well addressed by the techniques of gradient moment nulling and spatial presaturation. Gradient moment nulling (GMN) is an effective method for eliminating flow artifacts in gradient echo images, while presaturation is more applicable to the same task in spin echo acquisitions. The GMN technique also has useful applications in spin echo imaging such as combating the effects of tissue and CSF motion in long TE sequences. In contrast to presaturation, however, GMN is not suitable for suppressing artifacts due to pulsatile blood flow in spin echo images.

Entities:  

Mesh:

Year:  1990        PMID: 2345509     DOI: 10.1002/mrm.1910140214

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  Transmission, attenuation and reflection of shear waves in the human brain.

Authors:  Erik H Clayton; Guy M Genin; Philip V Bayly
Journal:  J R Soc Interface       Date:  2012-06-06       Impact factor: 4.118

Review 2.  Tools for cardiovascular magnetic resonance imaging.

Authors:  Ramkumar Krishnamurthy; Benjamin Cheong; Raja Muthupillai
Journal:  Cardiovasc Diagn Ther       Date:  2014-04

3.  Comparison of contrast-enhanced T1-weighted imaging using DANTE-SPACE, PETRA, and MPRAGE: a clinical evaluation of brain tumors at 3 Tesla.

Authors:  Zi-Qiao Lei; Chuan-Sheng Zheng; Qing Fu; Qi-Guang Cheng; Xiang-Chuang Kong; Ding-Xi Liu; Yi-Hao Guo; John Grinstead; Xiao-Yong Zhang
Journal:  Quant Imaging Med Surg       Date:  2022-01

4.  A Brief Survey on No-Reference Image Quality Assessment Methods for Magnetic Resonance Images.

Authors:  Igor Stępień; Mariusz Oszust
Journal:  J Imaging       Date:  2022-06-04

5.  Noninvasive determination of local wavespeed and distensibility of the femoral artery by comb-excited Fourier velocity-encoded magnetic resonance imaging: measurements on athletic and nonathletic human subjects.

Authors:  M Tarnawski; G Cybulski; D Doorly; C Dumoulin; R Darrow; C Caro
Journal:  Heart Vessels       Date:  1994       Impact factor: 2.037

6.  BLADE in sagittal T2-weighted MR imaging of the cervical spine.

Authors:  C Fellner; C Menzel; F A Fellner; C Ginthoer; N Zorger; A Schreyer; E M Jung; S Feuerbach; T Finkenzeller
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-26       Impact factor: 3.825

7.  Rapid quantification of oxygen tension in blood flow with a fluorine nanoparticle reporter and a novel blood flow-enhanced-saturation-recovery sequence.

Authors:  Lingzhi Hu; Junjie Chen; Xiaoxia Yang; Shelton D Caruthers; Gregory M Lanza; Samuel A Wickline
Journal:  Magn Reson Med       Date:  2012-08-22       Impact factor: 4.668

8.  Flow ghost artifact in slice-encoding direction mimicking vestibular schwannoma in contrast-enhanced 3D spoiled gradient-echo sequence.

Authors:  Shinji Naganawa; Tokiko Koshikawa; Hiroshi Fukatsu; Takeo Ishigaki; Ikuo Aoki
Journal:  Eur Radiol       Date:  2003-11-05       Impact factor: 5.315

9.  "Flow comp off": An easy technique to confirm CSF flow within syrinx and aqueduct.

Authors:  Anitha Sen
Journal:  Indian J Radiol Imaging       Date:  2013-01

10.  Comparison of T2 and T2*-weighted MR molecular imaging of a mouse model of glioma.

Authors:  Barbara Blasiak; Samuel Barnes; Tadeusz Foniok; David Rushforth; John Matyas; Dragana Ponjevic; Wladyslaw P Weglarz; Randy Tyson; Umar Iqbal; Abedelnasser Abulrob; Garnette R Sutherland; Andre Obenaus; Boguslaw Tomanek
Journal:  BMC Med Imaging       Date:  2013-07-18       Impact factor: 1.930

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.