Literature DB >> 23449519

Are there any differences in various polyaxial locking systems? A mechanical study of different locking screws in multidirectional angular stable distal radius plates.

Isabella Mehling1, Rebekka Scheifl, Dorothea Mehler, Daniela Klitscher, Hans Hely, Pol M Rommens.   

Abstract

Numerous angular stable plates for the distal radius exist, and technically based comparisons of the polyaxial locking interfaces are lacking. The aim of this mechanical study was to investigate three different locking interfaces of angular stable volar plates by cantilever bending: VA-LCP Two-Column Distal Radius Plates 2.4 mm (Synthes® GmbH, Oberdorf, Switzerland), IXOS® P4 (Martin, Tuttlingen, Germany) and VariAX™ (Stryker®, Duisburg, Germany). We assessed the strength of 0°, 5°, 10° and 15° screw locking angles and tested the bending strength from 10° to 5° angles by cyclic loading until breakage. The final setup repeated the above assessments by inclusion of four locking screws. The single screw-plate interfaces of the VA-LCP showed the highest bending moment at an angle of 0° and 5°, the IXOS® P4 at an angle of 10° and 15° and the VariAX™ when changing the insertion angle from 10° into 5°. The strength of polyaxial locking interfaces and mechanism of failure proved to be different among the examined plates.

Entities:  

Mesh:

Year:  2013        PMID: 23449519     DOI: 10.1515/bmt-2012-0105

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  4 in total

1.  [The volar locking plate for extension fractures of the distal radius].

Authors:  T Pillukat; R Fuhrmann; J Windolf; J van Schoonhoven
Journal:  Oper Orthop Traumatol       Date:  2015-12-17       Impact factor: 1.154

2.  Polyaxial locking plates in treating distal humeral fractures: a comparative randomized trial for clinical outcome.

Authors:  Moritz Crönlein; Martin Lucke; Marc Beirer; Dominik Pförringer; Chlodwig Kirchhoff; Peter Biberthaler; Karl F Braun; Sebastian Siebenlist
Journal:  BMC Musculoskelet Disord       Date:  2017-12-28       Impact factor: 2.362

3.  Is early full weight bearing safe following locking plate ORIF of distal fibula fractures?

Authors:  Michael Zyskowski; Markus Wurm; Frederik Greve; Sebastian Pesch; Francesca von Matthey; Patrick Pflüger; Moritz Crönlein; Peter Biberthaler; Chlodwig Kirchhoff
Journal:  BMC Musculoskelet Disord       Date:  2021-02-09       Impact factor: 2.362

4.  Outcome after polyaxial locking plate osteosynthesis in proximal tibia fractures: a prospective clinical trial.

Authors:  Dominik Völk; Markus Neumaier; Heike Einhellig; Peter Biberthaler; Marc Hanschen
Journal:  BMC Musculoskelet Disord       Date:  2021-03-18       Impact factor: 2.362

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.